The UT54ACTS153E is a dual four-to-one line selectors/mul-
tiplexer. Common inputs A and B select a value from one of
four sources for each section and routes the value from each
section to their respective outputs. Separate strobe inputs, G
are provided for each of the two four-line sections.
The device is characterized over the full military temperature
range of -55°C to +125°C.
PINOUT
16-Lead Flatpack
Top View
1G
B
1C3
1C2
1C1
1C0
1Y
V
SS
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
V
DD
2G
A
2C3
2C2
2C1
2C0
2Y
FUNCTION TABLE
SELECT
INPUTS
B
X
L
L
L
L
H
H
H
H
A
X
L
L
H
H
L
L
H
H
C0
X
L
H
X
X
X
X
X
X
DATA INPUTS
C1
X
X
X
L
H
X
X
X
X
C2
X
X
X
X
X
L
H
X
X
C3
X
X
X
X
X
X
X
L
H
OUTPUT
CONTROL
G
H
L
L
L
L
L
L
L
L
OUTPUT
Y
L
L
H
L
H
L
H
L
H
LOGIC SYMBOL
A
B
1G
1C0
1C1
1C2
1C3
(14)
(2)
(1)
(6)
(5)
(4)
(3)
EN
0
1
2
3
MUX
(7)
0
1
0
-
G
--
3
1Y
(15)
2G
(10)
2C0
(11)
2C1
(12)
2C2
(13)
2C3
(9)
2Y
Note:
1. Logic symbol in accordance with ANSI/IEEE Std 91-1984 and IEC
Publication 617-12.
1
LOGIC DIAGRAM
OUTPUT
CONTROL
1G
(1)
1C0 (6)
(5)
(7)
1C1
DATA 1
1C2
1Y
(4)
1C3
(3)
B
SELECT
(2)
A (14)
2C0
(10)
2C1 (11)
DATA 2
2C2
(12)
(9)
2Y
2C3
(13)
OUTPUT
CONTROL
2G
(15)
2
RADIATION HARDNESS SPECIFICATIONS
1
PARAMETER
Total Dose
SEU Threshold
2
SEL Threshold
Neutron Fluence
LIMIT
1.0E6
80
120
1.0E14
UNITS
rads(Si)
MeV-cm
2
/mg
MeV-cm
2
/mg
n/cm
2
Notes:
1. Logic will not latchup during radiation exposure within the limits defined in the table.
2. Device storage elements are immune to SEU affects.
ABSOLUTE MAXIMUM RATINGS
1
SYMBOL
V
DD
V
I/O
T
STG
T
J
T
LS
Θ
JC
I
I
P
D
Note:
1. Stresses outside the listed absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, functional operation of the device at these
or any other conditions beyond limits indicated in the operational sections is not recommended. Exposure to absolute maximum rating conditions for extended periods
may affect device reliability.
PARAMETER
Supply voltage
Voltage any pin
Storage Temperature range
Maximum junction temperature
Lead temperature (soldering 5 seconds)
Thermal resistance junction to case
DC input current
Maximum power dissipation
LIMIT
-0.3 to 7.0
-.3 to V
DD
+.3
-65 to +150
+175
+300
20
±10
1
UNITS
V
V
°C
°C
°C
°C/W
mA
W
RECOMMENDED OPERATING CONDITIONS
SYMBOL
V
DD
V
IN
T
C
PARAMETER
Supply voltage
Input voltage any pin
Temperature range
LIMIT
3.0 to 5.5
0 to V
DD
-55 to +125
UNITS
V
V
°C
3
DC ELECTRICAL CHARACTERISTICS FOR THE UT54ACTS153E
7
( V
DD
= 3.0V to 5.5V; V
SS
= 0V
6
; -55°C < T
C
< +125°C)
SYMBOL
V
IL
Description
Low-level input voltage
1
High-level input voltage
1
Input leakage current
Low-level output voltage
3
CONDITION
VDD
3.0V
5.5V
MIN
MAX
0.8
0.8
UNIT
V
V
IH
3.0V
5.5V
2.0
2.75
-1
1
0.4
0.4
2.4
3.15
-100
-200
6
8
-6
-8
2.1
0.84
10
1.6
100
200
V
µA
V
V
V
V
mA
I
IN
V
OL
V
IN
= V
DD
or V
SS
I
OL
= 6mA
I
OL
= 8mA
5.5V
3.0V
4.5V
3.0V
4.5V
3.0V
5.5V
V
OH
High-level output voltage
3
I
OH
= -6mA
I
OH
= -8mA
I
OS
Short-circuit output current
2 ,4
V
O
= V
DD
and V
SS
I
OL
Low level output current
10
V
IN
= V
DD
or V
SS
V
OL
= 0.4V
3.0V
5.5V
3.0V
5.5V
5.5V
3.0V
mA
I
OH
High level output current
10
V
IN
= V
DD
or V
SS
V
OH
= V
DD
-0.4V
mA
P
total
I
DDQ
∆I
DDQ
Power dissipation
2, 8, 9
Quiescent Supply Current
Quiescent Supply Current Delta
C
L
= 50pF
V
IN
= V
DD
or V
SS
For input under test
V
IN
= V
DD
- 2.1V
For all other inputs
V
IN
= V
DD
or V
SS
ƒ
= 1MHz
ƒ
= 1MHz
mW/
MHz
µA
mA
5.5V
5.5V
C
IN
C
OUT
Input capacitance
5
Output capacitance
5
0V
0V
15
15
pF
pF
Notes:
1. Functional tests are conducted in accordance with MIL-STD-883 with the following input test conditions: V
IH
= V
IH
(min) + 20%, - 0%; V
IL
= V
IL
(max) + 0%, -
50%, as specified herein, for TTL, CMOS, or Schmitt compatible inputs. Devices may be tested using any input voltage within the above specified range, but are
guaranteed to V
IH
(min) and V
IL
(max).
2. Supplied as a design limit but not guaranteed or tested.
3. Per MIL-PRF-38535, for current density
≤5.0E5
amps/cm
2
, the maximum product of load capacitance (per output buffer) times frequency should not exceed 3,765pF/
MHz.
4. Not more than one output may be shorted at a time for maximum duration of one second.
5. Capacitance measured for initial qualification and when design changes may affect the value. Capacitance is measured between the designated terminal and V
SS
at
frequency of 1MHz and a signal amplitude of 50mV rms maximum.
6. Maximum allowable relative shift equals 50mV.
7. All specifications valid for radiation dose
≤
1E6 rads(Si) per MIL-STD-883 Method 1019 Condition B.
8. Power does not include power contribution of any TTL output sink current
9. Power dissipation specified per switching output.
10. This value is guaranteed based on characterization data, but not tested.
4
AC ELECTRICAL CHARACTERISTICS FOR THE UT54ACTS153E
2
(V
DD
= 3.0V to 5.5V; V
SS
= 0V
1
, -55°C < T
C
< +125°C)
SYMBOL
t
PLH1
PARAMETER
Data to output Yn
CONDITION
C
L
= 30pF
V
DD
3.0V & 3.6V
4.5V & 5.5V
C
L
= 50pF
3.0V & 3.6V
4.5V & 5.5V
t
PHL1
Data to output Yn
C
L
= 30pF
3.0V & 3.6V
4.5V & 5.5V
C
L
= 50pF
3.0V & 3.6V
4.5V & 5.5V
t
PLH2
Strobe to output Yn
C
L
= 30pF
3.0V & 3.6V
4.5V & 5.5V
C
L
= 50pF
3.0V & 3.6V
4.5V & 5.5V
t
PHL2
Strobe to output Yn
C
L
= 30pF
3.0V & 3.6V
4.5V & 5.5V
C
L
= 50pF
3.0V & 3.6V
4.5V & 5.5V
t
PLH3
Select to output Yn
C
L
= 30pF
3.0V & 3.6V
4.5V & 5.5V
C
L
= 50pF
3.0V & 3.6V
4.5V & 5.5V
t
PHL3
Select to output Yn
C
L
= 30pF
3.0V & 3.6V
4.5V & 5.5V
C
L
= 50pF
3.0V & 3.6V
4.5V & 5.5V
Notes:
1. Maximum allowable relative shift equals 50mV.
2. All specifications valid for radiation dose
≤
1E6 rads(Si) per MIL-STD-883 Method 1019 Condition B.
Darlington transistors are a type that needs to be treated differently in transistor measurement. Darlington transistors have different powers, so the measurement methods are also different. So how to...
I am new to RF communication modules and I am using amiccom's A7105. I don't quite understand the idea of frequency hopping in RF communication. I would like to ask seniors with experience in this are...
[size=5]TimerA of MSP430 series microcontrollers has a complex structure and powerful functions. It is suitable for industrial control, such as digital motor control, ideal configuration for electric ...
I use 51 single chip microcomputer to do data acquisition. Does anyone have C program of AD7731? Can you provide reference? I really have no idea. I have been debugging for a long time. My email addre...
introduction
With the continuous optimization of surface mount technology (SMT) and the rapid development of chip component manufacturing technology, the application of chip mounters in the el...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
1. Introduction
Automobile pollution is one of the most important issues that people are most concerned about and need to solve urgently. As an important method for detecting automobile exhau...[Details]
In recent years, lighting has become an important area that countries around the world are targeting to promote energy conservation and environmental protection. According to statistics, about 20% ...[Details]
Abstract: The output of high-range acceleration sensor is less than 10 mV under the excitation of small signal. The noise of traditional test system may cover such small voltage signal, so that hig...[Details]
The TPS92210 is a single-stage LED lighting pulse width modulation (PWM) controller. The TRIAC dimmable solution not only regulates the LED current, but also achieves a power factor close to 1. The...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
Car lights, whether headlights, fog lights or tail lights, play an important role in driving safety. However, the material of the car lights determines that the probability of damage in a collision...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]
introduction
The core features of mobile value-added service products are mobility, immediacy and personalization. Mobile value-added services are a new service mode that is rapidly developing...[Details]
1 Introduction
Automatic Test
System The ATS (Automatic Test System) integrates all the stimulus and measurement equipment required for testing.
The computer
efficiently comp...[Details]
TPMS is the abbreviation of "Tire Pressure Monitoring System". It is mainly used to automatically monitor the tire pressure in real time when the car is driving, and to alarm for tire leakage and l...[Details]
With the tense global energy situation and the improvement of human environmental protection awareness, the research and development of power batteries is in full swing around the world. At present...[Details]
High specific energy lithium/thionyl chloride (Li/SOCl2) batteries are widely used in multi-functional intelligent meters (such as smart meters, water meters, etc.) as real-time clocks and memory b...[Details]
As a type of iron battery, lithium iron phosphate battery (hereinafter referred to as lithium iron battery) has always been widely concerned by industry friends (some people say that lithium iron b...[Details]