EEWORLDEEWORLDEEWORLD

Part Number

Search

LMZ1501-7EPHF

Description
AC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, METAL, CASE M02, MODULE
CategoryPower/power management    The power supply circuit   
File Size66KB,4 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LMZ1501-7EPHF Overview

AC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid, METAL, CASE M02, MODULE

LMZ1501-7EPHF Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE M02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-XXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage15.09 V
Minimum output voltage14.91 V
Nominal output voltage15 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output50 W
Fine-tuning/adjustable outputNO
Base Number Matches1
M Series
50 Watt AC-DC Converters
Input voltage range 85...264 V AC
1, 2 or 3 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
LGA
• Rugged electrical and mechanical design
• Outputs individually controlled with excellent
dynamic properties
• Operating ambient temperature range
–40...71°C with convection cooling
Selection chart
Output 1
Output 2
Output 3
U
o nom
I
o nom
[V DC]
5.1
5.1
12
12
15
15
24
24
48
48
12
12
15
15
5.1
5.1
5.1
5.1
[A]
8
8
4
4
3.4
3.4
2
2
1
1
2
2
1.7
1.7
5
5
5
5
U
o nom
I
o nom
[V DC]
-
-
-
-
-
-
-
-
-
-
12
12
15
15
12
12
15
15
[A]
-
-
-
-
-
-
-
-
-
-
2
2
1.7
1.7
0.7
0.7
0.6
0.6
U
o nom
I
o nom
[V DC]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12
12
15
15
[A]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.7
0.7
0.6
0.6
Input
voltage
U
i
[V AC]
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
Type
Options
LM 1001-7R
LMZ 1001-7R
LM 1301-7R
LMZ 1301-7R
LM 1501-7R
LMZ 1501-7R
LM 1601-7R
LMZ 1601-7R
LM 1901-7R
LMZ 1901-7R
LM 2320-7
LMZ 2320-7
LM 2540-7
LMZ 2540-7
LM 3020-7
LMZ 3020-7
LM 3040-7
LMZ 3040-7
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
www.power-one.com
Edition 4/04.2001
1
Geomagnetic sensor HMC1043
The output signal of the X direction of the geomagnetic sensor HMC1043 is always 0 after being amplified by AD623. What is the reason?...
JERRR Analog electronics
AM335x industrial control motherboard, supports wince, capacitive screen multi-touch...
[i=s] This post was last edited by szypf2011 on 2018-4-26 15:27 [/i] [color=#333333][backcolor=transparent][font=微软雅黑][size=18px] Human-machine interface (customizable wide temperature) industrial con...
szypf2011 Embedded System
How to use the ratiometric characteristics of sensors and ADCs to improve accuracy
Most sensors are analog in nature and must be digitized before they can be used in today's electronic systems. This application note covers the basic principles of ratiometric sensors and their use wi...
Aguilera Analogue and Mixed Signal
It is best to have a wrench when learning ARM
It is best to have a wrench when learning ARM...
3000mhz Microcontroller MCU
Who knows the 1939 agreement and how to obtain it?
Does anyone know how to obtain the 1939 Agreement? Are there any books on this subject?...
pxjinxing stm32/stm8
Build rtmp video live broadcast platform
1. Development and construction Reference implementation http://www.myhack58.com/Article/sort099/sort0102/2014/51843.htm http://www.myhack58.com/Article/sort099/sort0102/2014/51843.htm http://www.myha...
37°男人 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1590  202  1771  803  1006  33  5  36  17  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号