Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to -OUT voltage
-Sense to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +155
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
1.0
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V72B24C250BL
V7 2 B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
100W
5V
150W
8V
150W
12V
250W
15V
250W
24V
250W
28V
250W
36V
250W
48V
250W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Output Voltage
3V 3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
72V Mini Family
Page 1 of 11
Rev 2.8
06/2017
vicorpower.com
800 927.9474
72V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
35.2
111
41.7
36.5
115.5
121
1.5
Min
43
Typ
72
Max
110
150
42.6
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.1
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 6.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
72V Mini Family
Page 2 of 11
Rev 2.8
06/2017
vicorpower.com
800 927.9474
72V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
(89.3)
3.5
(99.6)
100
3000
1500
500
10
3.5
(100.3)
3.9
(110.6)
115
cURus, cTÜVus, CE
3.9
(111.3)
4.3
(121.6)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, out to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
72V Mini Family
Page 3 of 11
Rev 2.8
06/2017
vicorpower.com
800 927.9474
72V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 100W (e.g. V72B3V3C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
80.0
4.14
Typ
82.2
185
4.3
4.4
±0.02
34.8
34.8
Max
232
4.46
5.4
±0.2
30.3
41
41
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
21.2
5
V
OUT
, 150W (e.g. V72B5C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
84.0
6.03
Typ
85.0
120
6.25
7.9
±0.02
34.5
34.5
Max
150
6.47
8.6
±0.2
30
40.5
40.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
21
8
V
OUT
, 150W (e.g. V72B8C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
84.5
9.36
Typ
85.4
220
9.7
5.9
±0.02
21.6
21.6
Max
275
10.1
6.9
±0.2
18.75
25.4
25.4
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
19.1
5
12
V
OUT
, 250W (e.g. V72B12C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
86.5
13.7
Typ
87.6
300
14.3
8.5
±0.02
23.9
23.9
Max
375
14.9
9.5
±0.2
20.83
28.2
28.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
21.2
14.5
15
V
OUT
, 250W (e.g. V72B15C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.1
17.1
Typ
86.3
400
17.8
8.3
±0.02
19.2
19.2
Max
500
18.5
8.8
±0.2
16.67
22.6
22.6
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
17
11.6
72V Mini Family
Page 4 of 11
Rev 2.8
06/2017
vicorpower.com
800 927.9474
72V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
24
V
OUT
, 250W (e.g. V72B24C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.5
27.1
Typ
86.8
216
28.1
7.8
±0.02
12
12
Max
270
29.1
8.9
±0.2
10.42
14.1
14.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.6
7.28
28
V
OUT
, 250W (e.g. V72B28C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
87.5
31.5
Typ
88.5
270
32.7
7.7
±0.02
10.3
10.3
Max
338
33.9
8.2
±0.2
8.93
12.1
12.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
9.1
6.25
36
V
OUT
, 250W (e.g. V72B36C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
86.5
40.4
Typ
87.7
200
41.9
10.1
±0.02
7.98
7.98
Max
250
43.4
11
±0.2
6.94
9.37
9.37
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
7.07
4.85
48
V
OUT
, 250W (e.g. V72B48C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.5
53.7
Typ
87.0
202
55.7
8.7
±0.02
5.99
5.99
Max
253
57.7
10.5
±0.2
5.21
7.04
7.04
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
[align=left][color=rgb(62, 62, 62)]Figure 1 shows a typical power bank power supply system configuration. Since the power source is almost always a single lithium battery, and the output voltage is al...
The microcontroller simulates a HID descriptor to communicate with the host computer. Can a single interface be used to achieve PC-》HID and HID-》PC bi-phase communication? Can anyone make a suggestion...
"Modern Rectifier Technology: Active Power Factor Correction Technology" systematically introduces the principles and application technologies of power factor correction circuits. The book introduces ...
I have been working on the peer-to-peer network experiment for a long time, but the problem has not been solved. Looking at the TI E2E community (this is also the forum that the moderator Xin Xin reco...
There are many different ways of human-computer interaction. The more common ones are listed below:
Mouse interaction: Using a mouse to operate a computer and interact was the most common human...[Details]
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
The problem of dynamic sealing of equipment always exists with the operation of the equipment. Today, we have specially sorted out the various commonly used sealing forms, usage scope and character...[Details]
Is pure electric vehicles a false proposition for long-distance driving? At least from my personal perspective, based on current technological and infrastructure standards, I believe so. Below, I'l...[Details]
Topics: Bring Your Own Device (BYOD) trends; the impact of using employees' own mobile devices to control access to work facilities and equipment on information security; and ways to securely imple...[Details]
White light LEDs are voltage-sensitive devices. In actual operation, their upper limit is 20mA. However, the current often increases due to various reasons during use. If no protective measures are...[Details]
The Automotive Testing and Quality Assurance Expo (ATE 2025) will open on August 27th. At the expo, Rohde & Schwarz (R&S) will showcase six automotive testing solutions, themed "Intelligently Drivi...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
As the scale and business applications of national e-government networks continue to expand, the data and services transmitted over them are becoming increasingly sensitive and critical. To protect...[Details]
1 Source of creativity
With the further development of electronic technology, electronic pets have gradually entered people's family life. At present, there are two main categories of relative...[Details]
With the development of science, the use of variable frequency technology is becoming more and more widespread, and it is used in both industrial equipment and household appliances. Inverter air co...[Details]
Electric vehicles' 12V batteries don't rely on a generator to power them. Only gasoline-powered vehicles rely on the engine to drive a generator to generate electricity while driving, which is used...[Details]
Normally, we determine our location and where we want to go by comparing our surroundings with observation and simple GPS tools. However, this kind of reasoning is very difficult for self-driving c...[Details]
A patent disclosed by Ford proposes replacing traditional segmented side curtain airbags with integrated full-width side curtain airbags that span the side of the vehicle and can be deployed simult...[Details]
MQTT Ethernet I/O modules primarily collect I/O port information and transmit data over the network. In addition to being a TCP server, Ethernet I/O modules can also function as TCP clients. Furthe...[Details]