EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-409-30-1750LF

Description
Board Connector, 60 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-409-30-1750LF Overview

Board Connector, 60 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle

54122-409-30-1750LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
body width0.19 inch
subject depth0.689 inch
body length3 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationSN ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee3
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness79u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts60
Base Number Matches1
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
51 single chip microcomputer multiple interrupt problem - industrial control
1. I am working on a project. When programming the microcontroller, I use T0 (for display), T1 (for sequence control), T2 (for generating baud rate), and serial port interrupt (communication reception...
guweijie_gg Embedded System
EMULATOR simulator deployment failed, configuration data is corrupted, OS: WINDOWS 2003. How can I start it?
Microsoft Visual Studio 2005 Version 8.0.50727.762 (SP.050727-7600) Microsoft .NET Framework Version 2.0.50727 SP1 vs2005 SP1 Service Pack~ Configuration: Debug CHSEMU_SDK (ARMV4I) ------ 1>The config...
lyang996 Embedded System
Problems in EMC test of LED light board display
The monitor was subjected to surge, pulse group, static discharge and other EMC tests according to EN501213-2 standard. The following problems occurred: 1. The monitor "frozen" during surge and pulse ...
常伴久久 PCB Design
iLink technology tests and verifies high-speed buses
iLink technology tests and verifies high-speed buses Abstract : This paper introduces a new high-speed bus test and verification method . Through the iLink toolkit, integrated logic analyzer and digit...
feifei Test/Measurement
How to add WinCE components to PB5
I imported a BSP that came with the Flying OK2440III CD into Platform Builder 5.0 and opened the corresponding .pbxml file. I want to add some components to WinCE, such as Word Viewer, etc., but in th...
mcd511786450 Embedded System
How to copy the program in FLASH to SRAM through bootloader in F28335
The document says that the bootloader can move the program in FLASH to SRAM. If I want to implement such a function, that is, download the program to FLASH through the serial port, and then move the c...
zhangrong Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 574  2132  692  2213  1027  12  43  14  45  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号