EEWORLDEEWORLDEEWORLD

Part Number

Search

800-010-01Z110-26HN

Description
Circular Connector, 26 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size214KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

800-010-01Z110-26HN Overview

Circular Connector, 26 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,

800-010-01Z110-26HN Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing size10
Termination typeCRIMP
Total number of contacts26
Base Number Matches1
A
B
C
In-Line
Rear Panel Jam Nut Mount
Square Flange Mount
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
Series 800
Series 800 “Mighty Mouse”
Original UNF Threaded Coupling
Series 800 Receptacles – Crimp Termination
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 0- 0 11
Series
-0 1
Shell Style
M
Shell Material /
Finish
C
6-4
Shell Size- Insert
Arrangement
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contacts
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
N
Shell Key
Position
N
Normal
-01
In-Line
800-010
Receptacle with
Banding Platform
-02
Square Flange
for Front or Rear
Mounting
5-3
Aluminum / Black
6-1
Anodize
6-4
M
6-7
Aluminum / Electroless
7-1
Nickel
7-10
NF
8-13
Aluminum / Cadmium
9-4
with Olive Drab
9-19
Chromate
10-26
ZN
12-2
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
12-37
X
Pos. X
P
Pin
Y
Pos. Y
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
Z
Pos. Z
800-011
Receptacle with
Accessory Thread
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
-07
Jam Nut for Rear
Panel Mounting
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Prize-giving event | NI helps you design a more reliable data acquisition system
[Event Details] Prize-giving Event | NI helps you design a more reliable data acquisition system[Event time] From now until March 31, 2021[How to participate]1. Click the " I want to participate " but...
EEWORLD社区 Integrated technical exchanges
Winbile cooperates with Microsoft MVP department to recommend --- Microsoft Most Valuable Professional (MVP)
Winbile and Microsoft MVP Department cooperate to recommend --- Microsoft Most Valuable Professional (MVP) The honorary title of Microsoft MVP-Most Valuable Professional, which is certified globally. ...
jgalz Embedded System
Switching Power Supply Discussion
As shown in the figure below, what is the role of the 2.7ohm R2 in the red circle? LM3352 is a DC-DC converter. Why does the output DC voltage need to pass through such a small resistor before being s...
swz Power technology
MSP430 clock system
MSP430 can choose to use up to 3 oscillators depending on the model. We can choose the appropriate oscillation frequency according to the needs, and can turn off the oscillator at any time when not ne...
fish001 Microcontroller MCU
[LPC54100 usage] 03 ADC initial exploration
[color=#000]For an oscilloscope, there are two functions to design, one is acquisition and the other is display. At first, I wanted to use SPI to connect to a display screen, but it seemed a bit diffi...
johnrey MCU
Urgent! ! Who has a specific example of IoT application, with specific operation process of each process?
[size=24px][/size] Who has a specific example of IoT application, with specific operation process and specific description of each process? Not many points, only 200 points. Waiting online, thank you....
fastlin Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 395  789  2390  2886  692  8  16  49  59  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号