EEWORLDEEWORLDEEWORLD

Part Number

Search

A308220

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size239KB,6 Pages
ManufacturerEaton
Download Datasheet Parametric View All

A308220 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

A308220 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberA3000
Installation typeBOARD
Number of layers1
Rows1
Number of channels20
Rated current30 A
Rated voltage600 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
Base Number Matches1
MAGNUM
®
A31940707WR
Series A3000, LP3000 & CB3000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A3:
30A, 600V* #12-22 AWG
LP3: 30A, 150V #12-22 AWG
CB3: 30A, 600V #12-22 AWG
Wire Range:
#12-22 AWG CU
Center Spacing:
.437” or 7/16” (11.10 mm)
Screw Size:
#6-32 zinc plated philslot screws.
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing.
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature:
105°C (221°F) max., -40°C
(-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3500V (A3 & LP3); 8200V (CB3)
Agency Information:
UL/CSA; IEC Compliance,
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal;
20 Rating without ring terminal.
LP301105
CB31420807
A3000 & LP3000 Series
.437
(11.10)
.15
(3.8)
dia.
.65
(16.5)
Base & Rail Mount
Connectors
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.75
9.18
9.62
10.06
10.50
10.93
11.37
11.81
1.73
2.17
2.61
3.05
3.48
3.92
4.36
4.80
5.23
5.67
6.11
6.55
6.98
7.42
7.86
8.30
8.73
9.17
9.60
10.05
10.48
10.92
11.36
11.80
12.23
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.43
.87
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.50
9.18
9.62
10.06
10.50
10.93
11.37
11.81
BARRIER
ENDS
ONLY
C
Length
.98
1.43
1.87
2.31
2.75
3.18
3.62
4.06
4.50
4.93
5.37
5.81
6.25
6.68
7.12
7.56
8.00
8.43
8.87
9.31
9.75
10.18
10.62
11.06
11.50
11.93
12.37
.40
(10.2)
C
Mount End
Barrier End
.565
(19.3)
.76
(14.35)
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB3000 Series
.437
(11.10)
.19
(4.8)
dia.
.32
(8.1)
C
Mount End
Barrier End
Power Distribution Blocks
.70
(17.8)
.61
(15.5)
WIRE MANAGEMENT PRODUCTS
Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
12
Damped Input Filter Series 1
Switching regulators are often preferred over linear regulators because they are more efficient, and switching topologies rely heavily on input filtering. This circuit element, combined with the typic...
inoint98 Power technology
Please help, we want to make a device that supports MTP (using USB); however, Windows can only recognize it as PTP. Please help me analyze it.
After the device is plugged in, the device manager shows "still image camera" instead of the "portable media player" we need, which can directly synchronize media files with MS media player (version 1...
wyongyongge Embedded System
Debugging FPGAs with the SignalTap II Logic Analyzer
Abstract: This paper introduces the use of SignalTap II embedded logic analyzer in Quartus II, a programmable logic device development tool, and gives a specific design example, detailing the specific...
程序天使 FPGA/CPLD
Siemens Communications' fixed network, mobile network and operator service departments have been merged into Nokia. Where will the enterprise network go?
Siemens today officially announced that the fixed network, mobile network and operator service departments of the communications group will be merged into Nokia, thus confirming the rumors that the co...
1234 RF/Wirelessly
MSP430F149 Timer A capture function to measure pulse width. Can anyone help me find out what went wrong? The program is as follows
[code]/****Measure pulse width and display it with 1602****/ #include #include "cry1602.c" #define uint unsigned int #define uchar unsigned char uint pwm_star,pwm_end; uint width; uint i=0; uchar *s="...
qignsi2015 Microcontroller MCU
PCB process comparison: tin spraying vs gold plating vs immersion gold
[align=left][color=rgb(62, 62, 62)]Today, I will talk to you about the difference between immersion gold and gold plating of PCB circuit boards. Immersion gold and gold plating are processes commonly ...
ohahaha PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 59  902  245  2895  2043  2  19  5  59  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号