SV/F Series Tantalum Chip Capacitors
(Fuse Built-in Type)
DIMENSIONS [mm]
[B2 cases]
.
F
1
35R
L
H
PERFORMANCE CHARACTERISTICS
[C, D cases]
4.7
16R
[D2 cases]
.
F
W
1
H
Operating temperature range
−55
to +125°C with proper voltage
derating as shown in the following table.
DC working voltage and surge voltage
Rated voltage
Working
at 85°C
10
10
16
16
10
20
20 25
20 25
13 16
26 33
35
35
22
46
50
50
32
65
V
V
V
V
15
10R
Y
.F
W
1
L
Z
Z
W
2
Z
Z
W
2
Surge
(Unit: mm)
at 125°C 6.3
at 85°C
13
Case
EIA code
Code
B2
C
D2
D
3528
6032
5846
7343
L
3.5
±
0.2
6.0
±
0.2
5.8
±
0.2
7.3
±
0.2
W
1
2.8
±
0.2
3.2
±
0.2
4.6
±
0.2
4.3
±
0.2
W
2
2.3
±
0.1
2.2
±
0.1
2.4
±
0.1
2.4
±
0.1
H
1.9
±
0.2
2.5
±
0.2
3.2
±
0.2
2.8
±
0.2
Z
0.8
±
0.2
1.3
±
0.2
1.3
±
0.2
1.3
±
0.2
Y
−
0.4 C
−
0.5 C
Capacitance (at 20°C, 120 Hz)
Range:
1
µ
F to 47
µ
F
Tolerance:
±
20%,
±10%
Capacitance change with temperature
Not to exceed
−12%
at
−55°C,
+12% at
85°C, and +15% at 125°C
Tangent of loss angle (at 20°C, 120 Hz)
1
µ
F to 4.7
µ
F: less than 0.04
6.8
µ
F to 47
µ
F: less than 0.06
µ
F
1
DC Rated
Voltage
(Vdc)
10
16
20
25
35
B2
50
C
DC leakage current (at 20°C)
0.01 C
•
V
Note
µ
A or 0.5
µ
A, whichever is greater
Damp heat (90 to 95% RH at 40°C, 56 days (1344 h))
Capacitance change:
±5%
Tangent of loss angle: 150% of
initial requirements
DC leakage current:
initial requirements
Endurance (at 85°C, DC rated voltage, 2000 h)
Capacitance change:
±10%
Tangent of loss angle: initial requirements
DC leakage current:
125% of
initial requirements
Resistance to soldering heat
(solder reflow at 260°C, 10 s.
or solder dip at 260°C, 5 s.)
Capacitance change:
±5%
Leakage current:
initial requirements
Tangent of loss angle: initial requirements
Fuse blow-out characteristic
Blow-out time:
B2 case:
5 s Max. with 2 A applied
C case:
10 s Max. with 2 A applied
D2, D cases: 20 s Max. with 2 A applied
Note:
Product of capacitance in
µ
F and voltage in V.
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
D2, D
D
C, D2
B2
B2
C
C
C
D2, D
D2, D
D
D2, D
D
D
C
B2
B2
C
C
D2, D
D2, D
D
D
D2
See pages 25 and 26 for taping specifications.
20
SV/F Series
MARKINGS
The standard marking shows capacitance, DC rated voltage, polarity, and fuse built-in type.
[B2, D2 cases]
[C, D cases]
Capacitance in
µ
F
[Marking of production date code]
Y
2001
2002
2003
2004
M Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec.
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
Z
a
b
c
d
e
f
g
h
j
k
l
m
n
p
q
r
s
t
u
v
w
x
y
z
F
.
1
35R
.
F
4.7
DC rated voltage
Production date
16R
Note:
Production date code will repeat beginning in 2005.
Anode and Fuse built-in type
PART NUMBER SYSTEM
Bulk
SVF
B2
1V
105
M
Capacitance
tolerance
M for
±20%
Capacitance code in pF
First two digits represent significant figures.
Third digit specifies number of zeros to follow.
DC rated voltage 1V : 35 V
1E : 25 V
1D : 20 V
1C : 16 V
1A : 10 V
Case code
SV/ F Series
Tape and Reel
TE
SVFB21V105M
8
R
R: Orientation
Packing orientation
Feed direction
Tape width
8 mm for B2 case
12 mm for C, D, and D2 cases
See above
Tape and reel
Tape
Polarity mark
21