EEWORLDEEWORLDEEWORLD

Part Number

Search

8810EMM1-50

Description
Monitor TEE DC Block, 0.05MHz Min, 50000MHz Max, 3dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE
CategoryWireless rf/communication    Radio frequency and microwave   
File Size44KB,1 Pages
ManufacturerAPI Technologies
Websitehttp://www.apitech.com/about-api
Download Datasheet Parametric View All

8810EMM1-50 Overview

Monitor TEE DC Block, 0.05MHz Min, 50000MHz Max, 3dB Insertion Loss-Max, ROHS COMPLIANT PACKAGE

8810EMM1-50 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
Other features2.4 MM-M
Characteristic impedance50 Ω
structureCOAXIAL
Maximum DC voltage25 V
Maximum insertion loss3 dB
JESD-609 codee4
Maximum operating frequency50000 MHz
Minimum operating frequency0.05 MHz
RF/Microwave Device TypesMONITOR TEE DC BLOCK
Terminal surfaceGOLD
Maximum voltage standing wave ratio1.8
Base Number Matches1
BIAS TEES
2.4mm, 50 kHz - 50 GHz, 25 Volts / 150 mA
SPECIFICATIONS:
Models: 8810EMFX-50, 8810EFFX-50, 8810EMMX-50, 8810EFMX-50
Electrical:
Frequency Range
VSWR:
Insertion Loss:
100 kHz
50 kHz - 18 GHz
18 - 40 GHz
40 - 50 GHz
Impedance
Isolation (RF to Bias Port):
250 kHz - 26 GHz
100 kHz - 50 GHz
DC Voltage
DC Current
Rise Time (10% - 90%)
50 kHz - 50 GHz
1.80:1 Max.
Typical performance from 50 kHz - 50 GHz
Insertion Loss (dB)
0.5dB Typical
1.5dB Max.
3.0dB Max.
3.0dB Typ.; 4.0dB Max.
50 Ohms
50dB Typical
30dB Typ.
25 VDC Max.
150 mA Max.
< 9 pS Typical
Passivated Stainless Steel
Gold Plated Beryllium Copper
Aluminum with Chemical Conv. Coating
or Gold Plated Brass
Passivated Stainless Steel
Nickel Plated Brass
0
-1.0
-2.0
-3.0
-4.0
-5.0
.00001 .0001
.001
.01
.1
FREQ (GHz)
1
10
100
50
Mechanical:
2.4mm Connectors
Conductors
Housing
SMA Connectors
Mates with MIL-STD-348
Mates with 1.85mm & V* Connectors
VSWR
3.50
3.00
2.50
2.00
1.50
1.00
.00001 .0001
.001
.01
2.00
1.50
1.00
100
50
BNC Connectors
Mates with MIL-STD-348
.1
FREQ (GHz)
1
10
*V is a trademark of Anritsu Corp.
.25 [6.35]
.515±.030
[13.08±0.76]
DC Input Connector Options
Solder Post, X=1
BNC Female, X=3
.244
[6.20]
.489 [12.42]
Centered
DC Input
(SMA Female
Connector shown)
Option X = 2
3X Ø.102 [Ø2.59]
THRU
Connector
Overall
Configuration Port
Length
AC + DC
AC
Max.
Male
Female 1.63 [41.40]
8810EMFX-YY
Model
Numbers
1.060
[26.92]
Cent.
AC + DC
Port
1.20
[30.48]
AC Port
8810EFFX-YY
8810EMMX-YY
8810EFMX-YY
Female
Male
Female
Female 1.60 [40.64]
Male 1.75 [44.45]
Male
1.63 [41.40]
.19 [4.83]
Overall
Length
.63 [16.00]
HOW TO ORDER:
Model Number:
8810EYYX-50
Base Number
DC Connector Type
1 = Solder Post
2 = SMA Female Conn.
3 = BNC Female Conn.
Ordering Examples:
Model Number:
8810EFF2-50
50 KHz - 50 GHz, 2.4mm Fem/Fem
SMA Female DC Connector Type
Model Number:
8810EMF1-50
50 KHz - 50 GHz, 2.4mm Male/Fem
Solder Post DC Connector Type
8810E: REV P
Note: Dimensions in Brackets are Expressed in Millimeters and are for Reference Only.
Design specifications are subject to change without notice.
Contact factory for technical specifications before purchasing or use.
Aeroflex / Inmet, Inc.
• 300 Dino Drive, Ann Arbor, MI 48103 • U.S.A.
888-244-6638 or 734-426-5553 • FAX: 734-426-5557
www.aeroflex.com/inmet • inmetsales@aeroflex.com
CDMA1x Mobile Vehicle Video Surveillance Management System
[size=2][color=#000000]1 Design requirements[/color][/size][size=2][color=#000000]1.1 Technical design requirements[/color][/size][list][*][size=2]Use 2-card or 4-card CDMA1x wireless network for real...
ljy_8247 Industrial Control Electronics
Conjecture about Wince->WM
I would like to ask the experts in the forum, if I want to copy the upper layer of WM, such as the registry and applications directly into the wince project, can I get all the applications and interfa...
百胜电子 Embedded System
MSP and PSP of M3
Are the MSP and PSP of the M3 physically the same thing? The book says they are both registers R13. If they are not the same, which stack pointer do I access when I access R13?...
woody_chen Microcontroller MCU
Does anyone know how to solve the DEFECT of AMAT HDP PSG at 0.13LG ILD?
After the 0.13LG ILD PSG PROCESS, a defect with a plain appearance is always detected by YE. After SEM CUT check, it is confirmed that the defect is in the film. I have been solving it for 3 years but...
zhb319 PCB Design
Interface issues
I made an interface using evc programming in wince, and found that the buttons on it are too small. I want to enlarge them, but the width of the combo box control cannot be changed, only the length. D...
gw1300 Embedded System
The battery of my Neo 18V electric drill is running out of power. I want to get a transformer to power it directly. Please help me!!!
As the title says: The battery of the Neo 18V hand drill has no power left. I want to get a transformer to directly power it (I guess my hand drill is fake). The battery shell says 18V. I charged the ...
v115488 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2174  937  2296  51  2377  44  19  47  2  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号