EEWORLDEEWORLDEEWORLD

Part Number

Search

803-016-BB0M6-23PZ-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

803-016-BB0M6-23PZ-72 Overview

Interconnection Device

803-016-BB0M6-23PZ-72 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
Some knowledge and problems related to disks
Some of the questions I raise below are related to disks. For a given hard disk, it contains multiple cylinders, and each cylinder is composed of multiple tracks, and the tracks are composed of multip...
kunshan0512 Energy Infrastructure?
Frequently Asked Questions about Microwave Energy Application Technology
Frequently Asked Questions about Microwave Energy Application Technology Question 1: What is a microwave? Answer: Microwaves are electromagnetic waves like radio waves, infrared rays, and visible ligh...
JasonYoo RF/Wirelessly
Can anyone explain the function of adding a transistor between the output terminals AB of this 485 circuit?
I saw the 485 circuit of someone else's product as follows. Can anyone help explain the function of adding a transistor between the output terminals AB of this 485 circuit? Thank you...
stm32f103vct6 stm32/stm8
STM32F103VE(V3.5.0)+uCOS-III(V3.02.00)+IAR5.40
[color=#000][font=微软雅黑][size=5]There are too many STM32+uCOS based on MDK environment. Today I finally found a note about IAR environment. I just finished porting it and would like to share it with yo...
role_2099 stm32/stm8
The live broadcast with prizes will start on time at 10:00 am on November 27! Fujitsu empowers the transformation of automotive electronics technology
[align=left][b][font=微软雅黑][size=4]Live Topic: [/size][/font][/b][/align][align=left][font=微软雅黑][size=4]Fujitsu Empowers Technological Transformation in Automotive Electronics [/size][/font][/align][al...
EEWORLD社区 Automotive Electronics
Management of automatic fire alarm system
The automatic fire alarm system is composed of a trigger device, a fire alarm device, a fire alarm device and other auxiliary function devices. It can convert the physical quantities such as smoke, he...
aone2008 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2356  1959  1154  2493  87  48  40  24  51  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号