EEWORLDEEWORLDEEWORLD

Part Number

Search

803-016-CA0Z18-28NY-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-016-CA0Z18-28NY-72 Overview

Interconnection Device

803-016-CA0Z18-28NY-72 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
2015 Electrical Equipment Discussions
We chose the same major for our dreams, and the same game for our interests. Although some are gods, some are humans, and some are ghosts. But we are all a group of children who have given up treatmen...
123liulang321 Electronics Design Contest
What do the DDR SDRAM parameters die B/C/D/F mean?
I would like to ask about the parameters of DDR SDRAM. What do die B, die C, die D, and die F represent? NT5DS64M8BS-5T, die B NT5DS64M8CS-5T, die C K4H510838D-LCC, die D K4H510838F-LCC, die F These 4...
gundan Embedded System
EEWORLD University --- Tek's view on the design of current power supply products from the perspective of test and measurement
Tek's view on the design of today's power products from a test and measurement perspective : https://training.eeworld.com.cn/course/4655...
hi5 Talking
Keil LX51 related issues
A project, 1 common bank + 15 normal banks, when using keil BL51 to link the positioning code, the generated HEX80 file hex2bin, then bank link into a BIN file, burned into the flash, the system works...
yswlmike Embedded System
EEWORLD University Hall ---- Input and output restrictions 3
Input and output restrictions 3 : https://training.eeworld.com.cn/course/3647...
hi5 Analog electronics
Help: Does anyone know which embedded operating system Huawei uses for fixed-line terminal development?
Does anyone know which embedded operating system Huawei uses for fixed-line terminal development? Please advise if you know...
yql1980 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 909  2729  2658  2296  1385  19  55  54  47  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号