EEWORLDEEWORLDEEWORLD

Part Number

Search

803-014-AB2ZNU12-3PZ-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-014-AB2ZNU12-3PZ-72 Overview

Interconnection Device

803-014-AB2ZNU12-3PZ-72 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
How to get the Windows boot partition?
I have two hard disks on my machine. My boot.ini is: [boot loader] timeout=6 default=multi(0)disk(0)rdisk(0)partition(1)\WINDOWS [operating systems] multi(0)disk(0)rdisk(0)partition(1)\WINDOWS="Micros...
wshb007 Embedded System
How to use WinDbg or Watson Dump Viewer to analyze the Dump File captured on WinCE machine
Data Abort may occur on machines based on ARM+WinCE 5.0. It is too time-consuming to add debug information to gradually narrow the scope, so the ErrorReporting function is added to the Image. After Da...
tianweiming9527 Embedded System
Supplementary information on the two disassembled isolators and detailed disassembly pictures
[i=s]This post was last edited by btty038 on 2018-11-26 16:24[/i] [postbg]bg10.png[/postbg] These are two devices in the L-band of the power amplifier. . . . I won’t say any more, I’ll just upload a s...
btty038 RF/Wirelessly
Is there any easy way to tell whether the system is CE5 or CE6?
Something more general....
lzq1804 The Industrial Cloud
Ask an expert about soft interrupts
I would like to ask an expert about the soft interrupt problem. 1. In the interrupt vector table of dsp (5402), there are soft interrupts SINT17~SINT30. The chip does not give specific corresponding h...
rebor03 Analogue and Mixed Signal
MCU reset problem
STM32F407ZET6 resets every 4.4ms, what's going on???...
xxhhzz stm32/stm8

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1025  739  499  1513  1048  21  15  11  31  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号