EEWORLDEEWORLDEEWORLD

Part Number

Search

805-003-07Z19-10GC

Description
Circular Connector, 10 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size211KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

805-003-07Z19-10GC Overview

Circular Connector, 10 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle,

805-003-07Z19-10GC Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing size9
Termination typeCRIMP
Total number of contacts10
Base Number Matches1
A
B
C
D
E
HOW TO ORDER
Sample Part Number
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
80 5- 0 0 4
Series
-0 2
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
P
Pin
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
S
Socket
Standard #23 contacts
accept #22 through
#28 AWG wire. Special
contacts for #26 to #30
AWG are available. Use
the following contact
codes to specify these
contacts:
B
Position B
C
Position C
NF
Aluminum / Cadmium
with Olive Drab
Chromate
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin, #2226
Z1
Stainless Steel /
Passivated
H
Socket, #2226
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Understanding the alarm performance in arc fault detectors (fault arcs with 14 or more half cycles occurring within 1 second)
How to understand the alarm performance of 14 or more half-cycles of arc faults in 1s in GB14287.4 "Electrical Fire Monitoring System Part 4: Arc Fault Detector"? How to understand the alarm performan...
流萤宸殇 Test/Measurement
When using pb to generate wince, the following error is reported. Please give me some advice!
edimechn dlgmgr dlgmnem gwectrl btnctl stcctl edctl msgbox msgbox_hpc dlgmgr_hpc menu_hpc EditControlOs startup oomui oom startui cmbctl cdlctl imgctl lbctl scbctl sbcmnview nclientview gcacheview btn...
rock_17 Embedded System
How to evaluate battery life?
A simple and crude estimation method is to divide the nominal battery capacity by the average current. But this method is not very reliable. I believe that many people have driving experience, and exc...
qwqwqw2088 Analogue and Mixed Signal
STM32 uses AD to realize the touch of TFT color screen
Last time I saw on the forum that STM32 has a method to use AD acquisition to achieve touch, but I can't find any information. Does anyone know and can share it with me?...
zhang1234bbcc TI Technology Forum
Verilog language system learning (sequence)
Hello everyone, this is my first official blog. As people in the micro-era, we no longer have time to read lengthy blog posts. But when it comes to learning, there must be a process of accumulation. S...
lj8385174 FPGA/CPLD
Beginner's guide to switching power supply - Introduction to the basic principles of switching power supply
[size=3]The following summarizes the basic principles and parameter design references of switching power supplies[/size] [b]1. Circuit composition of switching power supplies[/b] The main circuit of t...
木犯001号 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1352  703  2696  314  452  28  15  55  7  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号