EEWORLDEEWORLDEEWORLD

Part Number

Search

801-009-01ZNU17-85HC

Description
Circular Connector, 85 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size317KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

801-009-01ZNU17-85HC Overview

Circular Connector, 85 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

801-009-01ZNU17-85HC Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH BLACK CHROMATE
Shell materialALUMINUM ALLOY
Housing size17
Termination typeCRIMP
Total number of contacts85
Base Number Matches1
A
B
C
D
E
F
G
H
J
K
L
-07
Jam Nut for Rear
M
© 2007 Glenair, Inc.
Series 801
Series 801 “Mighty Mouse”
Double-Start ACME Thread
Series 801 Receptacles – Crimp Termination
In-Line
801-009-01
Rear Panel Jam Nut Mount
801-009-07
Square Flange Mount
801-009-02
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 1- 0 1 0
Series
-02
Shell Style
Z1
Shell Material /
Finish
C
Aluminum / Black
Anodize
16-5 5
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
13-2
13-37
16-55
17-85
3 #23
1 #16
4 #23
7 #23
1 #12
10 #23
13 #23
4 #16
19 #23
26 #23
2 #12
37 #23
55 #23
85 #23
S
Contact Type
A
Shell Key
Position
M
801-009
Receptacle with
Banding Platform
-01
In-Line
Aluminum / Electroless
Nickel
Standard #23 contacts
A
accept #22 through
Normal
#28 AWG wire. Use the
following contact codes
to specify these contacts: Alternate Key
Positions:
P
Pin
NF
Aluminum / Cadmium
with Olive Drab
Chromate
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
B
C
D
ZN
801-010
Receptacle with
Accessory Thread
-02
Square Flange
for Front or Rear
Mounting
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
D-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Differences between MSP430F11x1 and MSP430F11x1A
MSP430F11x1: BSL version 1.10 (Errata: BSL2 and BSL3) The Security-Fuse is not intended for application use (Errata: FUSE2) To ensure safe operation, an external pull-down resistor is required at pin ...
Aguilera Microcontroller MCU
TM4C control stepper motor program
I need help from a great guy. How to use TIVAWARE's own library function to program a stepper motor with driver, with subdivisions of 1, 2, 4, 8. Thank you very much...
123tango Microcontroller MCU
R78G2 bit compilation error!
[font=新宋体][size=2]Compiler[/size][/font][color=#000][font=新宋体][size=2]CubeSuite+, using the lighting routine bit operation[/size][/font][/color][color=#000][font=新宋体][size=2]P13.0=~P13.0;[/size][/font...
xfttys Renesas Electronics MCUs
I found that lpc1343 GPIO0_11--GPIO1_3 cannot be used as a digital port
Recently, I accidentally used P0.11 (i.e. AD0) of LPC1343 as a digital port output to drive an LED, but found that it could not be configured as a digital port and could not be executed according to t...
gumuchixin NXP MCU
How to set up CAN filtering for STM32Cube
[table=98%,rgb(238, 238, 238)] [tr][td]How to set the CAN filter of STM32Cube, only two required IDs need to be interrupted, and all others are filtered. How to set it? /*##-2- Configure the CAN1 Filt...
newphj stm32/stm8
Discussion on the determination method of electronic balance gas chromatography
Electronic balance (1/10,000); gas chromatograph with FID detector (with splitter); 10 μL microinjector; several 20 mL small glass bottles with rubber stoppers; two medical syringes of 1 mL and 2 mL e...
setuok Industrial Control Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1543  2282  572  320  2897  32  46  12  7  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号