EEWORLDEEWORLDEEWORLD

Part Number

Search

933599140127

Description
4 Quadrant Logic Level TRIAC, 800V V(DRM), 8A I(T)RMS, TO-220AB, PLASTIC, SC-46, 3 PIN
CategoryAnalog mixed-signal IC    Trigger device   
File Size39KB,6 Pages
ManufacturerWeEn Semiconductors
Download Datasheet Parametric Compare View All

933599140127 Overview

4 Quadrant Logic Level TRIAC, 800V V(DRM), 8A I(T)RMS, TO-220AB, PLASTIC, SC-46, 3 PIN

933599140127 Parametric

Parameter NameAttribute value
package instructionFLANGE MOUNT, R-PSFM-T3
Reach Compliance Codeunknown
Shell connectionMAIN TERMINAL 2
ConfigurationSINGLE
JEDEC-95 codeTO-220AB
JESD-30 codeR-PSFM-T3
JESD-609 codee3
Number of components1
Number of terminals3
Package body materialPLASTIC/EPOXY
Package shapeRECTANGULAR
Package formFLANGE MOUNT
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
Maximum rms on-state current8 A
Off-state repetitive peak voltage800 V
surface mountNO
Terminal surfaceTIN
Terminal formTHROUGH-HOLE
Terminal locationSINGLE
Maximum time at peak reflow temperatureNOT SPECIFIED
Trigger device type4 QUADRANT LOGIC LEVEL TRIAC
Base Number Matches1
Philips Semiconductors
Product specification
Triacs
sensitive gate
GENERAL DESCRIPTION
Passivated, sensitive gate triacs in a
plastic envelope, intended for use in
general purpose bidirectional switching
and phase control applications, where
high sensitivity is required in all four
quadrants.
BT137 series E
QUICK REFERENCE DATA
SYMBOL
V
DRM
I
T(RMS)
I
TSM
PARAMETER
BT137-
Repetitive peak off-state
voltages
RMS on-state current
Non-repetitive peak on-state
current
MAX.
600E
600
8
65
MAX.
800E
800
8
65
UNIT
V
A
A
PINNING - TO220AB
PIN
1
2
3
tab
DESCRIPTION
main terminal 1
PIN CONFIGURATION
tab
SYMBOL
T2
main terminal 2
gate
main terminal 2
1 23
T1
G
LIMITING VALUES
Limiting values in accordance with the Absolute Maximum System (IEC 134).
SYMBOL
V
DRM
I
T(RMS)
I
TSM
PARAMETER
Repetitive peak off-state
voltages
RMS on-state current
Non-repetitive peak
on-state current
I
2
t for fusing
Repetitive rate of rise of
on-state current after
triggering
full sine wave; T
mb
102 ˚C
full sine wave; T
j
= 25 ˚C prior to
surge
t = 20 ms
t = 16.7 ms
t = 10 ms
I
TM
= 12 A; I
G
= 0.2 A;
dI
G
/dt = 0.2 A/µs
T2+ G+
T2+ G-
T2- G-
T2- G+
CONDITIONS
MIN.
-
-
-
-
-
-
-
-
-
-
-
-
-
-40
-
-600
600
1
8
65
71
21
50
50
50
10
2
5
5
0.5
150
125
MAX.
-800
800
UNIT
V
A
A
A
A
2
s
A/µs
A/µs
A/µs
A/µs
A
V
W
W
˚C
˚C
I
2
t
dI
T
/dt
I
GM
V
GM
P
GM
P
G(AV)
T
stg
T
j
Peak gate current
Peak gate voltage
Peak gate power
Average gate power
Storage temperature
Operating junction
temperature
over any 20 ms period
1
Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may
switch to the on-state. The rate of rise of current should not exceed 6 A/µs.
June 2001
1
Rev 1.400

933599140127 Related Products

933599140127 933522890127
Description 4 Quadrant Logic Level TRIAC, 800V V(DRM), 8A I(T)RMS, TO-220AB, PLASTIC, SC-46, 3 PIN 4 Quadrant Logic Level TRIAC, 600V V(DRM), 8A I(T)RMS, TO-220AB, PLASTIC, SC-46, 3 PIN
package instruction FLANGE MOUNT, R-PSFM-T3 FLANGE MOUNT, R-PSFM-T3
Reach Compliance Code unknown unknown
Shell connection MAIN TERMINAL 2 MAIN TERMINAL 2
Configuration SINGLE SINGLE
JEDEC-95 code TO-220AB TO-220AB
JESD-30 code R-PSFM-T3 R-PSFM-T3
JESD-609 code e3 e3
Number of components 1 1
Number of terminals 3 3
Package body material PLASTIC/EPOXY PLASTIC/EPOXY
Package shape RECTANGULAR RECTANGULAR
Package form FLANGE MOUNT FLANGE MOUNT
Peak Reflow Temperature (Celsius) NOT SPECIFIED NOT SPECIFIED
Certification status Not Qualified Not Qualified
Maximum rms on-state current 8 A 8 A
Off-state repetitive peak voltage 800 V 600 V
surface mount NO NO
Terminal surface TIN TIN
Terminal form THROUGH-HOLE THROUGH-HOLE
Terminal location SINGLE SINGLE
Maximum time at peak reflow temperature NOT SPECIFIED NOT SPECIFIED
Trigger device type 4 QUADRANT LOGIC LEVEL TRIAC 4 QUADRANT LOGIC LEVEL TRIAC
Base Number Matches 1 1

Recommended Resources

When the nrf24l01 module was conducting a communication experiment, the automatic response was unsuccessful. . .
I use NRF24L01 module for communication, and configure PIPE0 for automatic response. Why is there only a very small probability of receiving the automatic response signal (almost zero) during the expe...
longfly RF/Wirelessly
Why is there no news about BYD electric taxis in Shenzhen yet?
Fortunately, there are no reports of technical accidents. According to the normal plan, the next batch of more than 100 similar taxis will also be launched in the market in the near future. However, a...
zhaogztj66 Automotive Electronics
Can't even see the taillights? LED makes car tail lighting safer
In the early 20th century, nighttime driving was extremely dangerous. Drivers were illuminated by kerosene lamps, using hand signals and shouting to tell others what maneuvers to perform, while guessi...
EEWORLD社区 TI Technology Forum
C language essential articles
Why didn’t the upload succeed last time?...
cqwjfb Programming Basics
TIM issues with STM32
Are there TIM2_CH1 and TIM5_ETR in the STM32F103ZET6 chip? Why can't I find them in the manual?...
落日归侠 stm32/stm8
STM32 MCU distinguishes AT88SC102 and SLE4442 card types
Recently, I developed a project that needs to use SLE4442 card and AT88SC102 card. The microcontroller needs to automatically identify these two card types. The actual problem is that there are many d...
忘归尘 stm32/stm8

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2292  1115  838  892  429  47  23  17  18  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号