Part Number

Search

AC09-CZ0/14L2B02

Description
Rotary Coded Switch, 10 Positions, BCD Complement, Latched, 0.25A, 5VDC, Connector Terminal, Shaft Type Actuator, Panel Mount-threaded
CategoryMechanical and electronic products    switch   
File Size146KB,7 Pages
ManufacturerFuji Electric Co., Ltd.
Download Datasheet Parametric View All

AC09-CZ0/14L2B02 Overview

Rotary Coded Switch, 10 Positions, BCD Complement, Latched, 0.25A, 5VDC, Connector Terminal, Shaft Type Actuator, Panel Mount-threaded

AC09-CZ0/14L2B02 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator typeSHAFT TYPE
body width31 mm
body height35.8 mm
Body length or diameter40 mm
Contact (AC) maximum rated R load.5A@5VAC
Maximum contact current (AC)0.5 A
Maximum contact current (DC)0.25 A
Contact (DC) maximum rated R load.25A@5VDC
Maximum contact voltage (AC)5 V
Maximum contact voltage (DC)5 V
Electrical life50000 Cycle(s)
Graduation angle13.85 deg
Manufacturer's serial numberAC09
Installation featuresPANEL MOUNT-THREADED
Number of positions10
Number of switching segments1
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
sealIP65
surface mountNO
Switch actionLATCHED
switch functionBCD COMPLEMENT
Switch typeROTARY CODED SWITCH
Termination typeCONNECTOR
Base Number Matches1
Rotary Switches
AC09, 16 and 32
Digital code output type
Description
FUJI AC series rotary switches offer a
wide choice of output codes. They
feature sliding Au-flashed contacts for
high contact reliability. Inhibitor and
parity check circuits guard against
switch malfunctions caused by error
signals. With only seven connections to
make, these switches are an
economical solution to multiposition
switching needs.
I
I
Features
Au-flashed contacts for high contact
reliability.
Ratings
Operational current (A)
(resistive load)
0.05
0.5
0.05
0.25
The protection of operator section
meets the IP65 (IEC), so these
switches can be used in oil-splash
environments, such as on machine
tool control panels.
A wide choice of output codes fits a
broad range of applications.
Available step angles are 15, 30, and
360°/26 (13.85°). Real binary code,
complementary binary code, and real
gray code are available.
Switches are available with
connectors or with lock rings for easy
handling.
Stopper screw positions are user
selectable.
AC09
AC16
AC32
AF90-209, 210, 211
04
I
I
Performance
60V
–20 to +70°C
45 to 85%RH (non condensation)
50,000 operations
50,000 operations
250V AC, 1 minute
1500V AC, 1 minute
500MΩ or more
5,000MΩ or more
IP65 (IEC)
Volts
50V AC
5V AC
25V DC
5V DC
Rated insulation voltage
Operating temperature
Humidity
Service life
Mechanical
Electrical
Dielectric
strength
Between terminals
Between terminals and ground
Insulation
Between terminals
resistance
Between terminals and ground
Degree of protection (operator section)
I
Type number nomenclature
AC 09 – C Z 0 / 25 L1 E A01 / 0007
Basic type
Mounting
09: M9 nut
16: M16 adapter
32: Adapter
(32mm mounting pitch)
Type of code
R: Real binary code
C: Complementary binary code
G: Real gray code
Angle of step
Angle
X: 30°
W: 360°/13 (27.69°)
Y: 15°
Z: 360°/26 (13.85°)
Setting position
0 to 11
0 to 12
0 to 23
0 to 25
With or without lock ring
Blank: Without lock ring
0007: With lock ring
0009: With adhesive lock ring
With or without connector
Blank: 8-terminal, without connector
A01:
8-terminal, with right-angle connector
A02:
8-termianl, with straight connector
B00:
7-terminal, without connector
B01:
7-terminal, with right-angle connector
B02:
7-terminal, with straight connector
With or without stopper screw
Blank: With stopper screw
E:
Without stopper screw
Length of shaft (mm)
AC09 AC16
L1:
16
L2:
18
L3:
20
L4:
22
19.5
AC32
14.5
16.5
18.5
20.5
Start position
Available step angle
0 to 11: 30°
0 to 12: 360°/13 (27.69°)
0 to 23: 15°
0 to 25: 360°/26 (13.85°)
End position
Available step angle
0 to 11: 30°
0 to 12: 360°/13 (27.69°)
0 to 23: 15°
0 to 25: 360°/26 (13.85°)
Note:
When shorter action than the maximum range of
switch action is used, stopper screws are used.
However, stopper screws are not used if the
maximum action range is used when either 15°
(symbol Y) or 360°/26 (symbol Z) is specified.
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
04/207
Complete list of thermocouple indexing tables
It contains the graduation table of B, E, J, K, N, R, S, T and other graduation numbers....
huchuan987 Test/Measurement
SensorTag Conundrum
After buying sensortag, I found out that there were no development tools and no mobile phone to connect to, so it was just waiting to be collected dust....
luowhu Analogue and Mixed Signal
Question: Can 74AHC573 drive 8 optocouplers at the same time?
The following is the link address of my drawing, please come and have a look: http://b34.photo.store.qq.com/http_imgload.cgi?/rurl4_b=a81863bcd34ade06ac0a227b70647e40ab49ed55e2f0d762ee01c537351e59c529...
tsnana Embedded System
How to send and receive Ethernet frames under WinCE
How to send and receive Ethernet frames under WinCE...
nongjie66 Embedded System
Implementing communication between PDA and GPS OEM board in Windows CE.pdf
Implementing communication between PDA and GPS OEM board in Windows CE.pdf...
yuandayuan6999 MCU
Come and see the handsome guy, my son took the photo today
I went to a photo studio today to take pictures of my son, but he didn't cooperate at all and kept crying. In the end, I had no choice but to take a few pictures. Here are a few pictures for you to se...
tiankai001 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 62  560  1528  2801  640  2  12  31  57  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号