EEWORLDEEWORLDEEWORLD

Part Number

Search

ABS1413449

Description
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 30VDC, 5.1mm, Solder Terminal, Long Hinge Lever Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size276KB,11 Pages
ManufacturerPanasonic
Websitehttp://www.panasonic.co.jp/semicon/e-index.html
Environmental Compliance
Download Datasheet Parametric View All

ABS1413449 Overview

Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 30VDC, 5.1mm, Solder Terminal, Long Hinge Lever Actuator, Panel Mount

ABS1413449 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke5.1 mm
Actuator typeLONG HINGE LEVER
body width6.4 mm
body height11.1 mm
Body length or diameter19.8 mm
Maximum contact current (DC)0.1 A
Contact (DC) maximum rated R load.1A@30VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)30 V
Electrical life200000 Cycle(s)
JESD-609 codee4
Manufacturer's serial numberABS1
Installation featuresPANEL MOUNT
Maximum operating force0.25 N
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum pre-travel3.5 mm
sealENVIRONMENTALLY SEALED; IP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Terminal surfaceGold (Au)
Termination typeSOLDER
Base Number Matches1
VDE
HIGH ENVIRONMENTAL
RESISTANCE
TURQUOISE SWITCHES
ABS TYPE
FEATURES
19.3
11.1
6.4
• Subminiature size (19.8×11.1×6.4 mm)
• Sealed construction for use in adverse environment-Sealed construction by
epoxy resin and rubber cap greatly reduces possible miscontact due to
contaminants such as dust. Conforming to IP67* of IEC protective construction
classification
• Elastomer double molding technology, an industry first and ultrasonic swaging
technology contribute to uniform sealing in high production quantities
• Expansion of low-level circuit type
• We offer a Au clad 2-ply contact type (for small loads) that we developed
specifically for small current and voltage loads in the range of 1 mA to 100 mA
and 5 V to 30 V.
• UL/CSA/VDE/SEMKO approved
(AS for Au-clad twin layer, VDE and SEMKO are not approved.)
* Based on the protective construction classification of IEC, items which satisfy the test
requirements are denoted with an IP designation.
TYPICAL APPLICATIONS
RoHS compliant
• Automotive
• Home appliances (vacuum cleaner, air purifier)
• Others (gas cooking range)
ORDERING INFORMATION
Ex. ABS
1
1
1
0
4
0
3
Operating
Type of
Contact
force by
Terminal
Actuator
Contact*
Agency standard
switch
arrangement
pin plunger
(max.)
ABS:
1: Straight type 1: .110 quick-connect 1: SPDT
0: Pin plunger
4: 0.98 N
0: AgNi alloy
3: UL/CSA/VDE/SEMKO
Turquoise 4: Right angle
terminal
2: SPST-NC 1: Short hinge lever 5: 1.47 N
1: Au-clad
(AgNi alloy contact,
switch
5: Left angle
4: Solder terminal
3: SPST-NO 2: Hinge lever
triple layer
Au-clad triple layer type)
S type
5: PC board terminal
3: Long hinge lever
4: Au-clad
9: UL/CSA
6: Wire leads
4: Simulated roller
double layer
(Au-clad double layer type)
lever
6: Roller lever
8: Leaf lever
Wire and
terminal
position
Remarks: 1.
2.
3.
4.
5.
Standard packing: Dust protected type 100 pcs./carton, 1,000 pcs./case; Immersion protected type 50 pcs./case.
SPST-NC and SPST-NO are only available for wire leads type.
Leaf lever is only available for wire leads type
Wire leads type with agency standard will be discontinued from August 31, 2012.
As for wire position:
Straight type
Wire opposite to the
actuator side type
(Right angle)
Wire actuator side type
(Left angle)
5. Not every combination is available. Please refer to the following table, “PRODUCT TYPES”.
* Contact
0: AgNi alloy
AgNi alloy
1: Au-clad triple layer
Au-clad
CuNi alloy
AgNi alloy
4: Au-clad double layer
Au-clad
CuNi alloy
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e
AECTB2E 201201-T
Why can't the OTG dialog box pop up under wince6.0?
When I connect a USB OTG device in 6.0, a pop-up dialog box should appear, but it does not appear in mine? The hardware connection is normal, and the ActiveSync connection with the PC is normal....
hihigou Embedded System
Help! How to send the car's turn signal to the processor
How do I send the car's turn signal to the processor so that the processor knows the driver has issued a left or right turn command? Is there any circuit required?...
as心的距离 Automotive Electronics
Question about setting the clock source of MCLK to LFXT1
After the PUC signal, DCOCLK is automatically selected as the MCLK clock signal. The clock source of MCLK can be set to LFXT1 or XT2 as needed. The setting order is as follows: 1 Reset OscOff; 2 Clear...
shuizaiku7 Microcontroller MCU
Why don't you jump out? IE6.0 requests soft keyboard!
Hey guys, when using IESAMPLE, how can I make the soft keyboard pop up automatically when I click on the link address bar? I am so depressed. POCKET IE can pop up automatically. But POCKET IE is so ba...
sun139 Embedded System
Wait till I have money
When I have money, I will open two companies, one where I will be the boss and one where I will be an employee. I can fire the boss if I want to, and I can fire the employees if I want to. When I have...
lxyzy1999 Talking
28335 eQEP configuration speed measurement problem
Hello everyone, I have some questions about the configuration of eQEP and would like to ask you: In orthogonal mode, according to the operation manual: Low-speed measurement process: 1) Unit position ...
ZhuFeng Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 594  377  2724  1301  1597  12  8  55  27  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号