MIL–PRF (CWR Style) Established Reliability – T419 Series CWR19 Style MIL–PRF–55365/11
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
VDC
Rated
Cap
µF
3.3
4.7
6.8
10
15
22
22
33
33
47
68
100
150
220
330
3.3
4.7
6.8
10
15
15
15
22
22
33
47
68
68
100
150
220
330
2.2
3.3
4.7
4.7
6.8
6.8
6.8
10
10
10
10
15
15
22
33
47
47
µF
Case Code/
Case Size
KEMET/EIA
A/1005
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
D/1510
E/2010
E/2010
E/2010
F/2214
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
B/1505
B/1505
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
G/2711
G/2711
H/2915
H/2915
A/1005
A/1005
B/1505
C/2005
B/1505
C/2005
D/1510
B/1505
C/2005
D/1510
E/2010
D/1510
E/2010
E/2010
F/2214
F/2214
G/2711
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T419A335(1)004(2)(3)(4)
T419A475(1)004(2)(3)(4)
T419A685(1)004(2)(3)(4)
T419B106(1)004(2)(3)(4)
T419B156(1)004(2)(3)(4)
T419B226(1)004(2)(3)(4)
T419D226(1)004(2)(3)(4)
T419D336(1)004(2)(3)(4)
T419E336(1)004(2)(3)(4)
T419E476(1)004(2)(3)(4)
T419E686(1)004(2)(3)(4)
T419F107(1)004(2)(3)(4)
T419G157(1)004(2)(3)(4)
T419H227(1)004(2)(3)(4)
T419H337(1)004(2)(3)(4)
T419A335(1)006(2)(3)(4)
T419A475(1)006(2)(3)(4)
T419B685(1)006(2)(3)(4)
T419B106(1)006(2)(3)(4)
T419B156(1)006(2)(3)(4)
T419D156(1)006(2)(3)(4)
T419E156(1)006(2)(3)(4)
T419D226(1)006(2)(3)(4)
T419E226(1)006(2)(3)(4)
T419E336(1)006(2)(3)(4)
T419F476(1)006(2)(3)(4)
T419F686(1)006(2)(3)(4)
T419G686(1)006(2)(3)(4)
T419G107(1)006(2)(3)(4)
T419G157(1)006(2)(3)(4)
T419H227(1)006(2)(3)(4)
T419H337(1)006(2)(3)(4)
T419A225(1)010(2)(3)(4)
T419A335(1)010(2)(3)(4)
T419B475(1)010(2)(3)(4)
T419C475(1)010(2)(3)(4)
T419B685(1)010(2)(3)(4)
T419C685(1)010(2)(3)(4)
T419D685(1)010(2)(3)(4)
T419B106(1)010(2)(3)(4)
T419C106(1)010(2)(3)(4)
T419D106(1)010(2)(3)(4)
T419E106(1)010(2)(3)(4)
T419D156(1)010(2)(3)(4)
T419E156(1)010(2)(3)(4)
T419E226(1)010(2)(3)(4)
T419F336(1)010(2)(3)(4)
T419F476(1)010(2)(3)(4)
T419G476(1)010(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/11
Part Number
(See below for
part options)
CWR19C(3)335(1)(2)A(5)
CWR19C(3)475(1)(2)A(5)
CWR19C(3)685(1)(2)A(5)
CWR19C(3)106(1)(2)B(5)
CWR19C(3)156(1)(2)B(5)
CWR19C(3)226(1)(2)B(5)
CWR19C(3)226(1)(2)D(5)
CWR19C(3)336(1)(2)D(5)
CWR19C(3)336(1)(2)E(5)
CWR19C(3)476(1)(2)E(5)
CWR19C(3)686(1)(2)E(5)
CWR19C(3)107(1)(2)F(5)
CWR19C(3)157(1)(2)G(5)
CWR19C(3)227(1)(2)H(5)
CWR19C(3)337(1)(2)H(5)
CWR19D(3)335(1)(2)A(5)
CWR19D(3)475(1)(2)A(5)
CWR19D(3)685(1)(2)B(5)
CWR19D(3)106(1)(2)B(5)
CWR19D(3)156(1)(2)B(5)
CWR19D(3)156(1)(2)D(5)
CWR19D(3)156(1)(2)E(5)
CWR19D(3)226(1)(2)D(5)
CWR19D(3)226(1)(2)E(5)
CWR19D(3)336(1)(2)E(5)
CWR19D(3)476(1)(2)F(5)
CWR19D(3)686(1)(2)F(5)
CWR19D(3)686(1)(2)G(5)
CWR19D(3)107(1)(2)G(5)
CWR19D(3)157(1)(2)G(5)
CWR19D(3)227(1)(2)H(5)
CWR19D(3)337(1)(2)H(5)
CWR19F(3)225(1)(2)A(5)
CWR19F(3)335(1)(2)A(5)
CWR19F(3)475(1)(2)B(5)
CWR19F(3)475(1)(2)C(5)
CWR19F(3)685(1)(2)B(5)
CWR19F(3)685(1)(2)C(5)
CWR19F(3)685(1)(2)D(5)
CWR19F(3)106(1)(2)B(5)
CWR19F(3)106(1)(2)C(5)
CWR19F(3)106(1)(2)D(5)
CWR19F(3)106(1)(2)E(5)
CWR19F(3)156(1)(2)D(5)
CWR19F(3)156(1)(2)E(5)
CWR19F(3)226(1)(2)E(5)
CWR19F(3)336(1)(2)F(5)
CWR19F(3)476(1)(2)F(5)
CWR19F(3)476(1)(2)G(5)
(See below for
part options)
DC
Leakage
µA @ +20ºC
Max/5 Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
4.0
6.0
8.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.8
4.0
4.0
6.0
10.0
10.0
20.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
3.0
3.0
4.0
4.0
µA @ +20ºC
Max/5 Min
DF
% @ 20ºC
120 Hz Max
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
6.0
8.0
6.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0
% @ 20ºC
120 Hz Max
ESR
Ω @ +20ºC
100 kHz Max
12.0
12.0
12.0
8.0
8.0
8.0
4.0
4.0
3.0
3.0
3.0
2.0
1.0
1.0
0.9
12.0
12.0
8.0
8.0
8.0
5.0
3.0
5.0
3.5
3.5
3.5
1.5
1.0
1.1
1.1
0.9
0.9
12.0
12.0
8.0
5.5
8.0
5.5
5.0
8.0
5.5
4.0
3.5
5.0
3.0
2.0
1.5
1.5
1.0
Ω @ +20ºC
100 kHz Max
Moisture
Sensitivity
Reflow Temperature
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temperature
≤ 260ºC
Rated
Voltage
Rated Cap
Case Code/
Case Size
KEMET Part Number
MIL–PRF–55365/11
Part Number
DC
Leakage
DF
ESR
Moisture
Sensitivity
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET/CWR part number, insert B = Gold Plated, C = Hot solder dipped, H = Solder plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
Refer to Ordering Information for additional detail.
Electromagnetic compatibility is a new concept, which is an extension and extension of the concept of anti-interference. It has evolved from trying to prevent electromagnetic noise and electromagnetic...
After searching for several months, I finally found a job. My boss asked me to use vc to collect data. He just gave me a terminal and asked me to collect data. Where should I start? I would be very gr...
After a long delay, I can finally update it today. I spent two nights and more than an hour in the morning to rewrite the original independent flash read and write routines used to test sst25vf080 int...
With the rapid development of video surveillance technology, users' requirements for video surveillance products are also constantly increasing, with more complete and stable functions and clearer and...
[table=98%,rgb(238, 238, 238)] [tr][td]How can I find an inductor like the one in the picture below? Is there any software for designing passive filters with such a small inductance? Can anyone recomm...