EEWORLDEEWORLDEEWORLD

Part Number

Search

ZF2UGRMC

Description
PUSHBUTTON SWITCH, DPDT, LATCHED, 0.5A, 30VDC, THROUGH HOLE-RIGHT ANGLE, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size383KB,10 Pages
ManufacturerC&K
Environmental Compliance
Download Datasheet Parametric View All

ZF2UGRMC Overview

PUSHBUTTON SWITCH, DPDT, LATCHED, 0.5A, 30VDC, THROUGH HOLE-RIGHT ANGLE, ROHS COMPLIANT

ZF2UGRMC Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator materialPOLYESTER
Actuator stroke4.699 mm
Actuator typePUSHBUTTON
Other featuresPANEL MOUNTABLE
body width9 mm
body height6.9 mm
Body length or diameter21 mm
center contact materialBRASS
Center contact platingSILVER
Contact (AC) maximum rated R load.5A@125VAC
Maximum contact current (AC)0.5 A
Maximum contact current (DC)0.5 A
Contact (DC) maximum rated R load.5A@30VDC
Contact resistance0.02 mΩ
contact timeMAKE-BEFORE-BREAK
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)30 V
Electrical life35000 Cycle(s)
End contact materialBRASS
End contact platingSILVER
Insulation resistance1000000000 Ω
JESD-609 codee4
Manufacturer's serial numberF
Installation featuresTHROUGH HOLE-RIGHT ANGLE
Maximum operating force4 N
Maximum operating temperature70 °C
Minimum operating temperature-40 °C
sealTOP AND BOTTOM SEALED
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typePUSHBUTTON SWITCH
Terminal surfaceSilver (Ag)
Terminal materialBRASS
Termination typeSOLDER
Base Number Matches1
F Series
Pushbutton Switches
A
Features/Benefits
Up to 10 poles per module
Various contact terminals
Various mounting & switch
ganging configurations
Pushbutton
Typical Applications
Audio selection
Digital equipment interface
Medical equipment interface
Mechanical indicator buttons
RoHS compliant
Specifications
SWITCHING POWER: F module max. AC/DC: Silver: 50 VA/15W,
Gold: 1 VA/300 mW.
SWITCHING VOLTAGE: F module max. AC/DC: Silver: 125/30V,
Gold: 50/30 V.
SWITCHING CURRENT: F module max. AC/DC: Silver: 0.5A/0.5A,
Gold: 0.04A/0.01A.
CARRYING CURRENT: Max at du = 20C: Silver: < 2A, Gold: <0.5A.
DIELECTRIC STRENGTH (50 Hz, 1 min.): Chassis/contact: ^1500V
Between contacts: ^1500V.
OPERATING LIFE “OA/EE” (24V/200mA): >105 operations
“GR”: >3.5 x 104 operations.
CONTACT RESISTANCE: Initial: Typical %10 mΩ, max. 20 mΩ
After operating life: %100 mΩ
INSULATION RESISTANCE: ^109
between open contacts,
^109
between chassis and contacts.
CAPACITANCE (at f = 10 kHz): %0.7 pF between 2 contacts.
TOTAL TRAVEL/LATCHING TRAVEL: 4.7mm/3.3mm (.185 inch/
.130 inch).
All models and options are RoHS compliant and compatible.
NOTE:
All models and options are RoHS compliant and compatible.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
TYPICAL F OPERATING FORCE: 2U: 6.5N (650 grams); 4U: 6.5N
(650 grams); 6U: 7.5N (750 grams); 8U: 9.0N (900 grams); 10U:
9.0N (900 grams).
EUROPEAN TYPICAL SF OPERATING FORCE:
2U: 3.5N±0.5N (350 grams±100 grams); 4U: 5N±1N (500
grams±100 grams); 6U: 6.5N±1N (650 grams±100 grams); 8U:
9.0N±1N (900 grams±100 grams).
OPERATING TEMPERATURE RANGE: -40˚C to 70˚C.
Materials
HOUSING: Polycarbonate UL 94V-0 or polyester UL 94V-0.
ACTUATOR: Polyester UL 94V-0.
MOVABLE CONTACTS: Bimetal brass, silver plated, gold plate
over nickel.
STATIONARY CONTACTS & TERMINALS: Brass, silver plated,
gold plated.
TERMINAL BOARD: Polyester UL 94V-0.
RETURN SPRING: Music wire.
TERMINAL SEAL: RTV adhesive sealant.
CHASSIS: Steel.
LOCKOUT PIN: Steel.
BLOCKERS: Steel.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages A-89 thru A-97. For additional options not shown in catalog, consult Customer Service Center.
If requesting only a switch, select either a North American or European switch as noted below. Chassis and buttons are sold
separately. If multiple stations are selected, we will assume all switches are the same unless noted otherwise.
North American Order Code - Switch Only
Designation
F
F Series
FLT
Light touch F series
ZF
Central mounted F series
Contact Arrangement
2U
2PDT
Mechanical Function
4U
4PDT
OA
Momentary
6U
6PDT
EE
Alternate (push-push)
8U
SPDT
GR
Interlock
10U
1OPDT
AOR
Central release
OASP
Momentary with lockout
GRSP
Interlock with lockout
Terminal Sealing
(NONE)
None
TB
Top/bottom
Terminal Style
(NONE)
Solder lugs & PC pins
01A
Cut solder lugs
01B
Cut PC pins, for other configurations,
consult factory
Electrical Function
(NONE)
BBM
M
MBB (special)
Contact Material
(NONE)
Silver, AG
AU
Gold
Dress nut*
*Central mounted F series only
(NONE)
No dress nut
B
Black
C
Chrome
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A-88
www.ck-components.com
TI Cup C Question Discussion
[align=center][b]Simple DC Electronic Load (Question C) [/b][/align][align=center][b][font=华文中宋][size=14.0pt] [Undergraduate Group] [/size][/font][/b][/align][align=left][b]1. [/b][b]Task [/b][/align]...
wengjiangang Power technology
mp3 module
I would like to ask if any of you have made or are making MP3 modules? Based on single chip microcomputer [[i] This post was last edited by guoyuanqiang on 2010-12-10 16:34 [/i]]...
guoyuanqiang MCU
RF Engineer's Reflection (Reprinted)
Netizens often ask on the Internet what knowledge an RF engineer should have and how to do RF work well. There is a discussion post about this issue that has dozens of replies, which seems to be a com...
qinkaiabc RF/Wirelessly
Use of timer
#include #include #define uint unsigned int #define uchar unsigned char sbit D1=P1^0; uchar temp,tt; uint num; uchar code table[]={0xc0,0xf9,0xa4,0xb0,0x99,0x92}; void delay(uint z ); void main() { TM...
liufengjing9 51mcu
Can the microcontroller I/O output PWM wave be directly connected to a DC motor?
As the title says, let P10 output PWM wave, and then directly connect it to one level of the DC motor and the other level to ground. Why doesn't the DC motor rotate?Is it necessary to connect an exter...
skyman_liu 51mcu
【CN0051】Driving the AD9233/AD9246/AD9254 ADC in AC-Coupled Baseband Applications
Circuit Function and BenefitsThe ADA4937-1 converts an AC-coupled, single-ended input signal to a differential signal suitable for driving the AD9246 14-bit, 125 MSPS analog-to-digital converter (ADC)...
EEWORLD社区 ADI Reference Circuit

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2637  383  1217  1163  1719  54  8  25  24  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号