EMI Suppression Capacitors
X2 / 275 Vac
Not for new design
X2 capacitors with small dimensions
Rated ac voltage 275 V, 50/60 Hz
1)
Construction
I
I
I
I
B 81 133
Dielectric: polyester (MKT)
Internal series connection
Plastic case (UL 94 V-0)
Epoxy resin sealing, flame-retardant
Features
I
Self-healing properties
Terminals
I
Parallel wire leads, tinned
I
Standard lead lengths see table.
Lead spacing
±
0,4
Lead diameter Lead length
l
1
∅
d
(mm)
(mm)
0,8
1,0
6–1
6–1
26
±
2
30
+
2
Other lead lengths available upon request.
Marking
Manufacturer’s logo, lot number,
date code, rated capacitance (coded),
capacitance tolerance (code letter),
rated ac voltage, type number,
interference suppression sub-class (X2),
style (MKT), self-healing (SH),
climatic category,
awarded marks of conformity.
Delivery mode
≤
27,5 mm
37,5 mm
Lead spacing
≤
27,5 mm
Lead spacing = 37,5 mm
AAAAA C1223
XX-22n M 275V~
AAAAA B1225
XX-2µ2 M 300V~
B81133 X2 MKT/SH
40/100/21/C
250V~ 250V~
B81133 X2 MKT/SH
40/100/21/C
V
D E
IEC 384
14 (2)
KMK0569-Q
300V~
300V~ IEC 384-14(2)
KMK0627-L
Bulk (untaped)
Taped (Ammo pack or reel)
or notes on taping,
refer to chapter “Taping and packing”, page 274.
Marks of conformity
Marks of
conformity
Standards
EN 132400 / IEC 384-14, 2nd edition
UL 1283 (250 V)
UL 1414
CSA C22.2 No. 0; 1 (250 V)
CSA C22.2 No. 0; 8 (250 V)
for 300 V (lead spacing = 37,5 mm):
DIN EN 132400 / IEC 384-14, 2nd edition 18643-4670-0011/315A3 ZS/HV
LR59709-35
CSA C22.2 No. 0; 8
E157153
UL 1283
1) Rated ac voltage for lead spacing 37,5 mm = 300 V, 50/60 Hz
Certificate
9516010-01
E157153
E97863/95NK32316
LR 59709
LR 59709
240
12/00
B 81 133
275 Vac
Not for new design
Ordering codes and packing units
Lead
spacing
±
0,4
mm
15
C
R
Maximum
dimensions
b
×
h
×
l
(mm)
5,0
×
10,5
×
18,0
5,0
×
10,5
×
18,0
6,0
×
11,0
×
18,0
7,0
×
12,5
×
18,0
8,5
×
14,5
×
18,0
8,5
×
14,5
×
18,0
Ordering code
1)
X2
Packing units (pcs)
Ammo Reel
Untaped
pack
Lead length
6 mm
26 mm
1300
1300
1100
900
700
700
700
600
500
400
350
350
350
300
250
—
—
1000
1000
1000
1000
500
500
720
630
510
540
510
320
320
280
260
200
90
1000
1000
1000
800
500
500
500
500
450
350
300
200
200
200
150
100
70
22 nF
33 nF
47 nF
68 nF
0,10
µ
F
0,15
µ
F
B81133-C1223-M
***
1170
B81133-C1333-M
***
1170
B81133-C1473-M
***
960
B81133-C1683-M
***
830
B81133-D1104-M
***
680
B81133-D1154-M
***
680
B81133-C1104-M
***
B81133-C1154-M
***
B81133-C1224-M
***
B81133-D1334-M
***
B81133-D1474-M
***
B81133-C1334-M
***
B81133-C1474-M
***
B81133-C1684-M
***
B81133-C1105-M
***
B81133-C1155-M
***
680
580
480
390
370
—
—
—
—
—
22,5
0,10
µ
F 6,0
×
15,0
×
26,5
0,15
µ
F 7,0
×
16,0
×
26,5
0,22
µ
F 8,5
×
16,5
×
26,5
0,33
µ
F 10,5
×
16,5
×
26,5
0,47
µ
F 11,0
×
20,5
×
26,5
0,33
µ
F
0,47
µ
F
0,68
µ
F
1,0
µ
F
1,5
µ
F
11,0
×
21,0
×
31,5
11,0
×
21,0
×
31,5
12,5
×
21,5
×
31,5
14,0
×
24,5
×
31,5
18,0
×
27,5
×
31,5
27,5
37,5
2)
2,2
µ
F 18,0
×
32,5
×
41,5 B81133-B1225-M
***
—
Capacitance tolerance:
±
20 % = M (closer tolerances upon request)
ˆ
1) Replace the *** by the code number for the required lead length or packing.
000 = lead length 6 mm (untaped)
026 = lead length 26 mm (untaped)
289 = taped, Ammo pack
189 = taped, reel
2) Rated ac voltage for lead spacing 37,5 mm = 300 V, 50/60 Hz
241
12/00
X2
B 81 133
275 Vac
Not for new design
Technical data
Climatic category
in accordance with IEC 60068-1
Lower category temperature
T
min
Upper category temperature
T
max
Passive flammability category
in acc. with IEC 40 (CO) 752
Damp heat test
Limit values after damp
heat test
40/100/21
−
40
°
C
+
100
°
C
C
21 days/40
°
C/93 % relative humidity
Capacitance change |
∆
C/C|
Dissipation factor change
∆
tan
δ
Insulation resistance
R
is
or time constant
τ
=
C
R
⋅
R
is
275 V (50/60 Hz)
≤
5%
≤
5
⋅
10
−3
(at 1 kHz)
≥
50 % of minimum
as-delivered values
Permissible
continuous ac voltage
DC test voltage
Dissipation factor tan
δ
(in 10
−3
)
at 20
°
C
(upper limit values)
Permissible continuous dc voltage 630 V
1800 V, 2 s
C
R
≤
0,1
µ
F 0,1
µ
F
<
C
R
≤
1
µ
F
1 kHz 8
8
10 kHz 15
15
100 kHz 30
–
C
R
>
0,33
µ
F
10 000 s
C
R
>
1
µ
F
10
–
–
at
Insulation resistance
R
is
or time constant
τ
=
C
R
⋅
R
is
at 20
°
C, rel. humidity
≤
65 %
(minimum as-delivered values)
Impedance
Z
versus frequency
f
(typical values)
C
R
≤
0,33
µ
F
30 000 M
Ω
242
12/00
B 81 133
275 Vac
Not for new design
Pulse handling capability
X2
Maximum permissible voltage change per unit of time for non-sinusoidal voltages (pulse, sawtooth).
V
R
Max. rate of voltage rise
V
pp
/
τ
in V/
µ
s (for
V
pp
=
V
R
)
ˆ
Lead spacing
15 mm
275 Vac
60
22,5 mm
30
27,5 mm
20
37,5 mm
8
ˆ
ˆ
For
V
pp
<
V
R
, the permissible voltage rise rate
V
pp
/
τ
may be multiplied by the factor
V
R
/V
pp
.
Also refer to the calculation example
in chapter “General technical information”, page 302.
V
R
Pulse characteristic
k
0
in V
2
/
µ
s (for
V
pp
≤
V
R
)
ˆ
Lead spacing
15 mm
275 Vac
45 000
22,5 mm
20 000
27,5 mm
12 000
37,5 mm
55 000
243
12/00
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgele-
genen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsge-
sellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this bro-
chure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be con-
sidered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1