EEWORLDEEWORLDEEWORLD

Part Number

Search

CB30221907

Description
30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector    terminals   
File Size239KB,6 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

CB30221907 Overview

30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

CB30221907 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberCB3000
Installation typeBOARD
Number of layers1
Rows1
Number of channels19
Rated current30 A
Rated voltage600 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
Base Number Matches1
MAGNUM
®
A31940707WR
Series A3000, LP3000 & CB3000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A3:
30A, 600V* #12-22 AWG
LP3: 30A, 150V #12-22 AWG
CB3: 30A, 600V #12-22 AWG
Wire Range:
#12-22 AWG CU
Center Spacing:
.437” or 7/16” (11.10 mm)
Screw Size:
#6-32 zinc plated philslot screws.
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing.
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature:
105°C (221°F) max., -40°C
(-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3500V (A3 & LP3); 8200V (CB3)
Agency Information:
UL/CSA; IEC Compliance,
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal;
20 Rating without ring terminal.
LP301105
CB31420807
A3000 & LP3000 Series
.437
(11.10)
.15
(3.8)
dia.
.65
(16.5)
Base & Rail Mount
Connectors
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.75
9.18
9.62
10.06
10.50
10.93
11.37
11.81
1.73
2.17
2.61
3.05
3.48
3.92
4.36
4.80
5.23
5.67
6.11
6.55
6.98
7.42
7.86
8.30
8.73
9.17
9.60
10.05
10.48
10.92
11.36
11.80
12.23
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.43
.87
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.50
9.18
9.62
10.06
10.50
10.93
11.37
11.81
BARRIER
ENDS
ONLY
C
Length
.98
1.43
1.87
2.31
2.75
3.18
3.62
4.06
4.50
4.93
5.37
5.81
6.25
6.68
7.12
7.56
8.00
8.43
8.87
9.31
9.75
10.18
10.62
11.06
11.50
11.93
12.37
.40
(10.2)
C
Mount End
Barrier End
.565
(19.3)
.76
(14.35)
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB3000 Series
.437
(11.10)
.19
(4.8)
dia.
.32
(8.1)
C
Mount End
Barrier End
Power Distribution Blocks
.70
(17.8)
.61
(15.5)
WIRE MANAGEMENT PRODUCTS
Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
12
【Download and get a gift】Download the Vishay brochure! (Now - October 31) - Photonics Month Series of Activities
Event time : Now to October 31st. How to participate : 1. Go to https://www.eeworld.com.cn/Vishay/application/ , register and download relevant information.2. The registration number must be a multipl...
EEWORLD社区 Discrete Device
Commands to view computer network failures
1. Ping command The Ping command is widely used in checking network failures. Network administrators often receive reports from remote users that their hosts are faulty, such as being unable to log in...
liudong2008lldd RF/Wirelessly
[Evaluation of EC-01F-Kit, the NB-IoT development board of Essence] 03. Discussion: Frequent disconnection after the device is connected to the network
[i=s]This post was last edited by Li Baiyi on 2021-12-22 21:11[/i]When debugging EC-01F MQTT to access Alibaba, the normal communication state is frequently disconnected and then automatically connect...
李百仪 RF/Wirelessly
Can someone please help me figure out the program problem? Why can't 1602 display the time?
[i=s] This post was last edited by ny760117144 on 2014-6-11 18:46 [/i] //P3^2 and P3^3 low level detection, LCD output circle number, serial number, low level time #include #include #define uchar unsi...
ny760117144 51mcu
Get an MSP430 LaunchPad, exchange it or exchange it for chip coins
[img]http://www.ti.com/diagrams/med_msp-exp430g2_msp-exp30g2.jpg[/img] As the title says, this MSP430 LaunchPad is brand new, the box and everything are still there, I don't need it. I can exchange it...
白丁 Buy&Sell
If you use tweezers to short-circuit the output of a power supply, how many states will the load have?
At the moment the tweezers are short-circuited, the load becomes 0. At the moment the tweezers are released, the load changes from 0 back to its original value. Is this change process completed instan...
sfcsdc Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 385  1656  899  1249  2314  8  34  19  26  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号