EEWORLDEEWORLDEEWORLD

Part Number

Search

CV01L-A3BP-FREQF

Description
HCMOS/TTL Output Clock Oscillator, 1MHz Min, 150MHz Max, ROHS COMPLIANT PACKAGE-14/4
CategoryPassive components    oscillator   
File Size688KB,1 Pages
ManufacturerCardinal Components
Environmental Compliance  
Download Datasheet Parametric View All

CV01L-A3BP-FREQF Overview

HCMOS/TTL Output Clock Oscillator, 1MHz Min, 150MHz Max, ROHS COMPLIANT PACKAGE-14/4

CV01L-A3BP-FREQF Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresSYMMETRY 45/55 ALSO AVAILABLE
Maximum control voltage3 V
Minimum control voltage0.3 V
maximum descent time10 ns
Frequency Adjustment - MechanicalNO
frequency stability50%
JESD-609 codee3
linearity20%
Manufacturer's serial numberCV01
Installation featuresTHROUGH HOLE MOUNT
Maximum operating frequency150 MHz
Minimum operating frequency1 MHz
Maximum operating temperature75 °C
Minimum operating temperature-30 °C
Oscillator typeHCMOS/TTL
Output load10 TTL, 15 pF
physical size20.8mm x 13.2mm x 5.08mm
longest rise time10 ns
Maximum supply voltage3.465 V
Minimum supply voltage3.135 V
Nominal supply voltage3.3 V
surface mountNO
maximum symmetry40/60 %
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Base Number Matches1
Thru Hole VCXO
CARDINAL COMPONENTS
• Wide frequency range
• Extended temperature range and tight symmetry available
• Broad range of pullability
Series CV01
Part Numbering Example: CV01 L - A3 B3 - 15.360 A P
CV01
SERIES
CV01
L
VOLTAGE
Blank =
5.0V
L = 3.3V
A3
OPERATING TEMP.
A1=-10°C ~ +50°C
A2=-10°C ~ +60°C
A3=-30°C ~ +75°C
A4=-40°C ~ +75°C
A6=-0°C~+70°
B3
STABILITY
B6 = ±100 ppm
BP = ±50 ppm
BR = ±25 ppm
15.360
FREQUENCY
A
TUNING RANGE
A = ±50 ppm
B = ±100 ppm
C = ±150 ppm
D = ±200 ppm
E = ±250 ppm
F = ±300 ppm
G = ±350 ppm
P
LINEARITY
Blank = ±20%
Q
= ±15%
P
= ±10%
Specifications:
Frequency Range:
1.000 MHz to 150.000 MHz
Available Stability Options:
±100 ppm
±50 ppm
±25 ppm
Output Series:
Input Voltage:
Frequency Tuning Range:
TTL/HCMOS
+5.0 VDC ±5%
+3.3 VDC ±5%
±50 ppm
±100 ppm
±150 ppm
±200 ppm
±250 ppm
±300 ppm
±350 ppm
+2.5 VDC ±2.0 VDC (5V)
+1.65 VDC @ ±1.35VDC
±20% Max.
±15% Max.
±10% Max.
Positive
TTL V
OL
=0.4 V Max.
TTL V
OH
=2.4 V Min.
HCMOS V
OL
=10%V
DD
V Max.
HCMOS V
OH
=90%V
DD
V Min.
-0°C to +70°C
-40°C to +85°C
10 TTL
15 pf HCMOS
20 mA (1.000 to 20.000 MHz)
40 mA (20.010 to 50.000 MHz)
50 mA (50.010 to 160.000 MHz)
10 ns
40/60%
45/55%
10 ms
-55°C to +125°C
CVO1
External Control Voltage:
Linearity:
Polarity of Freq. Slope:
Output Voltage:
Operating Temperature
Range Options:
Output Load:
Maximum Input Current:
Maximum Rise/Fall Time:
Duty Cycle:
Max Start-Up Time:
Storage Temperature:
155 Route 46 West
Wayne, NJ 07470
Rev:
V-090414-13
Cardinal Components, Inc.
V-9
TEL:
(973)785-1333
E-MAIL: sales@cardinalxtal.com
WEB: http://www.cardinalxtal.com
The challenge is clear: a comprehensive analysis of high-definition video surveillance technology
Page 1: High-definition demand is highlighted Page 2: Basics of high-definition applications Page 3: High-definition front-end acquisition technology Page 4: High-definition encoding standards Page 5:...
xyh_521 Industrial Control Electronics
【Help】MS430f449 interrupt service routine
I would like to ask: In the C language programming of MSP430, how to call the interrupt service program? What form is used?In the example in the accompanying book: #pragma vector = WDT_VECTOR_interupt...
wanxd Microcontroller MCU
Huawei releases lighting IoT solution that can save 80% of urban lighting electricity consumption
[p=28, 2, left][color=rgb(51, 51, 51)][font=frutigernext,]On March 15, 2016, Huawei released the industry's first multi-level intelligent control lighting IoT solution at CeBIT 2016 (Hannover Consumer...
fish001 Energy Infrastructure?
The circuit board capacitor keeps heating up and smoking, and is about to burn out
The 10uF polarized capacitor connected between VCC and GND on the circuit board keeps heating up and smoking. What are the possible reasons? Help...
喝罐红牛继续飞 PCB Design
Motor heating problem!
55KW inverter with 6-pole 55KW motor, output distance is about 150 meters, equipped with output reactor, after installation and debugging, the motor temperature is tested to be 80~90 degrees, the moto...
eeleader Industrial Control Electronics
I am a newbie and I don't understand the DA of MSP430F5529LP
Masters, help! ~~Does MSP430F5529 have DA function? :Sad: Are there any other learning materials specifically about 5529? Because the project deadline is coming soon, I still don’t understand this chi...
tamtam Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2224  2735  363  413  1909  45  56  8  9  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号