EEWORLDEEWORLDEEWORLD

Part Number

Search

D38999/20F-B-4PA

Description
MIL Series Connector, 4 Contact(s), Metal, Male, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size63KB,1 Pages
ManufacturerHiRel Connectors Inc
Websitehttps://hirelco.net
Download Datasheet Parametric View All

D38999/20F-B-4PA Overview

MIL Series Connector, 4 Contact(s), Metal, Male, Crimp Terminal, Receptacle

D38999/20F-B-4PA Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999, COMPATIBLE CONTACT: M39029/58-363
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsENVIRONMENT RESISTANT; FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial numberD38999/20
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialMETAL
Housing sizeB
Termination typeCRIMP
Total number of contacts4
Base Number Matches1
D38999/20
Square Flange Wall Mount Environment Resistant Receptacle
SHELL SHELL
SIZE
SIZE CODE
9
11
13
15
17
19
21
23
25
A
B
C
D
E
F
G
H
J
MIL-DTL-38999
Series III – Threaded Coupling
W
W'
.144/.083 [3.65/2.10]
.144/.083 [3.65/2.10]
.144/.083 [3.65/2.10]
.144/.083 [3.65/2.10]
.144/.083 [3.65/2.10]
.144/.083 [3.65/2.10]
.171/.083 [4.35/2.10]
.171/.083 [4.35/2.10]
.171/.083 [4.35/2.10]
VV Thd
-6g 0.100R
M12 x 1.0
M15 x 1.0
M18 x 1.0
M22 x 1.0
M25 x 1.0
M28 x 1.0
M31 x 1.0
M34 x 1.0
M37 x 1.0
.098/.083 [2.5/2.1]
.098/.083 [2.5/2.1]
.098/.083 [2.5/2.1]
.098/.083 [2.5/2.1]
.098/.083 [2.5/2.1]
.098/.083 [2.5/2.1]
.126/.083 [3.2/2.1]
.126/.083 [3.2/2.1]
.126/.083 [3.2/2.1]
1.240 [31.5] MAX
W
<3>
W'
<4>
V
<3>
V'
<4>
SEE CONTACT
STYLE
DESIGNATOR
ON ORDERING
INFORMATION
PAGE
CHAMFERED OR
ROUNDED 4 PL
S
2 PL
PP
4 PL
ØP
4 PL
2 PL
2 PL
R1
VV Thd
BLUE BAND
R2
.520/.500 [13.2/12.7]
(FULLY MATED INDICATOR BAND - RED)
BB Thd
SHELL SHELL
SIZE
CLASS 2A
SIZE CODE
0.1P-0.3L-TS
9
11
13
15
17
19
21
23
25
<1>
<2>
<3>
<4>
=
=
=
=
BB Thd
.6250
.7500
.8750
1.0000
1.1875
1.2500
1.3750
1.5000
1.6250
ØP
±.008
[±0.20]
PP
±.008
[±0.20]
R1
<1>
.719 [18.26]
.812 [20.62]
.906 [23.01]
.969 [24.61]
R2
<2>
.594 [15.09]
.719 [18.26]
.812 [20.62]
.906 [23.01]
.969 [24.61]
S
±.012
[±0.3]
.938 [23.8]
1.031 [26.2]
1.125 [28.6]
1.219 [31.0]
1.312 [33.3]
1.438 [36.5]
1.562 [39.7]
1.688 [42.9]
1.812 [46.0]
V
+.000/-.049
[+0.00/-1.25]
.820 [20.83]
.820 [20.83]
.820 [20.83]
.820 [20.83]
.820 [20.83]
.820 [20.83]
.790 [20.07]
.790 [20.07]
.790 [20.07]
V'
+.055/-.000
[+1.4/-0.0]
.768 [19.5]
.768 [19.5]
.768 [19.5]
.768 [19.5]
.768 [19.5]
.768 [19.5]
.736 [18.7]
.736 [18.7]
.736 [18.7]
A
B
C
D
E
F
G
H
J
.128 [3.25] .216 [5.49]
.128 [3.25] .194 [4.93]
.128 [3.25] .194 [4.93]
.128 [3.25] .194 [4.93]
.128 [3.25] .194 [4.93] 1.062 [26.97]
.128 [3.25] .194 [4.93] 1.156 [29.36] 1.062 [26.97]
.128 [3.25] .194 [4.93] 1.250 [31.75] 1.156 [29.36]
.154 [3.91] .242 [6.15] 1.375 [34.93] 1.250 [31.75]
.154 [3.91] .242 [6.15] 1.500 [38.10] 1.375 [34.93]
FRONT OR REAR PANEL MOUNTING
REAR PANEL MOUNTING ONLY
FOR CLASS F, G, K, S, & W
FOR CLASS J & M
DIMENSIONS ARE IN INCHES [MILLIMETERS]
United States
– 760 W. Wharton Drive, Claremont CA. 91711
Ph: 909-626-1820
FAX: 909-399-0626
Web:
www.HIRELCO.com
Europe
– 5 Rue Des Longues Raies, Z.I. Des Garennes, 78440; Gargenville, France
Ph: 33(0) 1-309-38999 or U.K. 44(0)1-980-843887
FAX 33(0) 1-309-38913
Web:
www.HIRELCO.com
C-13
How can I import ADI's SPICE model into MultiSim?
Hello everyone: I downloaded the AD637 SPICE Macro Model from the ADI website below and got a cir file. How can I import it into MultiSim? Thank you. [url=http://www.analog.com/en/special-linear-funct...
PSIR ADI Reference Circuit
Please advise: What is the meaning of the .reset segment in the C language of 2812 and its location in the memory
Question 1: When downloading a program for simulation debugging or running it offline after burning it to FLASH, does the program have to execute the series of processes of "reset from 0X3F FFC0 → exe...
xiongbg Microcontroller MCU
[Video sharing] Engineer It series (I) Temperature factors to consider when selecting integrated motor drives
Hello everyone~~ Today I share with you a video that explains what to consider when choosing an integrated motor driver from the perspective of temperature control. I hope it will be helpful for your ...
德州仪器_视频 Analogue and Mixed Signal
I want to monitor the operation of compressed files, how can I do it? Please give me some ideas
I want to record the name of a file if there is a compression operation on it in the program. How can I do this?...
alywang Embedded System
Transfer 4 network cameras, with PTZ, only 4* yuan
4 cameras for sale at a bargain price, 49.8 yuan each, brand new with pan/tilt head, can be used with just an internet cable and a 12V power supply, you can use this camera to see what's going on at h...
rogerangel Buy&Sell
Open source ISP-VB6 source code, only supports AT89S51/AT89S52
ISP-VB6.0 source code for AT89S51 and AT89S52. There is no confidentiality button, please avoid it if you are an enterprise user. There is no erase button either, please create an empty .HEX file to e...
xu__changhua 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 661  2052  572  1684  1763  14  42  12  34  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号