EEWORLDEEWORLDEEWORLD

Part Number

Search

D4C-4560

Description
Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 30VDC, Wire Terminal, Center Roller Lever Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size2MB,15 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

D4C-4560 Overview

Snap Acting/Limit Switch, SPDT, Momentary, 0.1A, 30VDC, Wire Terminal, Center Roller Lever Actuator, Panel Mount

D4C-4560 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator typeCENTER ROLLER LEVER
Other featuresO.T. = 50 DEG, P.T. = 13 DEG, D.T. = 3 DEG, T.T.= 63 DEG
body width16 mm
body height45.5 mm
Body length or diameter40 mm
Contact (AC) maximum rated R load.1A@125VAC
Maximum contact current (AC)0.1 A
Maximum contact current (DC)0.1 A
Contact (DC) maximum rated R load.1A@30VDC
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)30 V
Electrical life200000 Cycle(s)
Manufacturer's serial numberD4C
Installation featuresPANEL MOUNT
Maximum operating force6.67 N
Maximum operating temperature70 °C
Minimum operating temperature-10 °C
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
Base Number Matches1
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Sealing characteristics that meet IEC IP67 degree of
protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
CSM_D4C_DS_E_10_1
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1)(2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
1
MSP430G2553 clock and clock interrupt
[color=#252525][size=18px]#include "msp430G2553.h" [/size][/color] [color=#252525][size=18px]//************* *Main function******************************[/size][/color] [color=#252525][size=18px]void ...
fish001 Microcontroller MCU
mc55 c language program
My development environment is Linux. After debugging the functions of the MC55 GPRS module with minicom, I now want to use a C language program to implement the transmission of AT commands. However, t...
dingedward Programming Basics
What file system does WinCE use to manage the remaining flash space? FAT32?
s3c2410+WinCE board kernel starts at block 46 on the nand flash. I found the FAT32 DBR on page 0 of block 47, and the FAT32 FSInfo Sector and Backup Boot Sector on the first page of block 47, which sh...
nddz Embedded System
RF Wireless Charging
I am a researcher, and my supervisor asked me to research radio frequency wireless charging. I have no idea what to do now. I hope the experts can give me some suggestions....
xiaoheiqun RF/Wirelessly
EEWORLD University Hall----How To Read an Academic Paper
How To Read an Academic Paper : https://training.eeworld.com.cn/course/4526Teach you how to read a professional paper in three minutes...
通通 DIY/Open Source Hardware
Implementing FIR source code based on TI's TMS320F2812
I haven't studied the source code of FIR based on TI's TMS320F2812 carefully. If you find it useful, you can study it carefully....
安_然 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2314  2835  934  584  541  47  58  19  12  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号