D20XB40 ........ D20XB100
20 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
Voltage
400 V to 1000 V
Current
20 A
IN LINE BIG
FEATURES
UL recognition file number
E320541, Vol. 2
Ideal for printed circuit board
High case dielectric strength of 2000 Vrms
High surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2011/65/EU
and WEEE 2002/96/EC
~
~
~
~
MECHANICAL DATA
Case
:
IN LINE BIG. Epoxy meets UL 94V-0 flammability rating.
Polarity
:
As marked on body
Mounting
Torque
:
5.5cm-kg (5 in.- Ibs.)
Terminals
:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test
TYPICAL APPLICATIONS
Used in ac-to-dc bridge full wave rectification for monitor,
TV, printer, switching mode power supply, adapter, audio
equipment, and home appliances applications.
Maximum Ratings and Electrical Characteristics at 25 ºC
D20XB40
D20XB60
D20XB60
600
420
D20XB80
D20XB80
800
560
(Note 1)
(Note 2)
D20XB100
D20XB100
1000
700
Marking Code
V
RRM
V
RMS
I
F(AV)
I
FSM
V
DIS
I
2
t
T
j
T
stg
Peak recurrent reverse voltage (V)
Maximum RMS Voltage (V)
Max. Average forward current
Peak forward surge current 10ms single half
sine-wave superimposed on rated load
(
Jedec Method
)
Dielectric strength (terminals to case, AC 1 min.)
Current squared time (rating for fusing)
(1ms.<t<10ms. Tc = 25º C)
Operating temperature range
Storage temperature range
D20XB40
400
280
20 A at Tc: 87 °C
3.2 A at 25 °C
240 A
2000 V
240 A
2
sec
-55 to +150 °C
-55 to +150 °C
Electrical Characteristics at Tamb = 25 °C
V
F
I
R
R
th (j-c)
R
th (j-a)
Max. Instantaneous forward vololtage @ = 10 A
Maximum DC Reverse Current
at Rated DC Blocking Voltage
Typical Thermal Resistance
@ T
A
= 25 °C
@ T
A
=125°C
1.0 V
10 µA
500 µA
1.5 °C/W
22 °C/W
(Note 1)
(Note 2)
Junction-case
Junction-Ambient
Notes: 1. Unit case mounted on aluminum plate heatsink
2. Units mounted on P.C.B. without heatsink
www.fagorelectronica.com
Document Name: d20xb
Version: Nov-12
Page Number: 1/4
D20XB40 ........ D20XB100
20 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
Ordering information
PREFERRED P/N
D20XB60 TY
PACKAGE CODE
TY
DELIVERY MODE
PAPER TRAY
BASE QUANTITY
40
UNIT WEIGHT (g)
7
Package Outline Dimensions: (mm)
IN LINE BIG
4.8
4.4
C.118(3.0)
x45°
30.3
29.7
Marking code
3.8
3.4
MC
WWY
2.7
2.3
2.4
2.0
1.1
0.9
7.7
10.2
9.8
7.3
7.7
7.3
Year code
Week code
20.3
19.7
5.0
4.8
11.2
10.8
4.2
3.8
18.0
17.0
3.4
3.1
2.9
2.5
0.8
0.6
www.fagorelectronica.com
Document Name: d20xb
Version: Nov-12
Page Number: 2/4
D20XB40 ........ D20XB100
20 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
Ratings and Characteristics
(Ta 25 ºC unless otherwise noted)
I
F
, instantaneous forward current (A)
TYPICAL FORWARD CHARACTERISTICS
PER BRIDGE ELEMENT
MAXIMUM FORWARD CURRENT DERATING
CURVE
1000
100
25
20
15
10
5
0
20
10
1
0.1
0.6
I
F(AV)
, average forward current (A)
0.8
V
F
, forward voltage (V)
1.0
1.2
1.4
1.6
1.8
2.0
40
60
80
Case temperature (°C)
100 120 140 160 180
I
FSM
, peak forward surge current (A)
MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT PER BRIDGE ELEMENT
TYPICAL JUNCTION CAPACITANCE
Cj, junction capacitance (pF)
400
300
200
100
90
80
60
40
20
1
2
4
6
10
20
40 60 100
600
500
400
300
200
100
0
0.1
0.5 1
2
5
10 20
50 100 200
800
T
j
= 25 °C
Number of cycles at 60Hz
V
R
, reverse voltage (V)
I
R
, Instantaneous reverse current (µA)
1000
100
TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
T
A
= 125 °C
10
1
T
A
= 25 °C
0.1
0
20
40
60
80
100
Percent of rated peak reverse voltage (%)
www.fagorelectronica.com
Document Name: d20xb
Version: Nov-12
Page Number: 3/4
D20XB40 ........ D20XB100
20 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
Disclaimer
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.
www.fagorelectronica.com
Document Name: d20xb
Version: Nov-12
Page Number: 4/4