EEWORLDEEWORLDEEWORLD

Part Number

Search

HDWM-20-53-G-S-120

Description
Board Stacking Connector, 20 Contact(s), 1 Row(s), Male, Straight, Solder Terminal,
CategoryThe connector    The connector   
File Size86KB,1 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

HDWM-20-53-G-S-120 Overview

Board Stacking Connector, 20 Contact(s), 1 Row(s), Male, Straight, Solder Terminal,

HDWM-20-53-G-S-120 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Connector typeBOARD STACKING CONNECTOR
Contact to complete cooperationGOLD (10)
Contact completed and terminatedGOLD (3)
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
DIN complianceNO
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Manufacturer's serial numberHDWM
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded1
OptionsGENERAL PURPOSE
Terminal pitch1.27 mm
Termination typeSOLDER
Total number of contacts20
UL Flammability Code94V-0
Base Number Matches1
REVISION
NOTES:
1.
C
REPRESENTS A CRITICAL DIMENSION.
ASSEMBLY OPERATION
2. MAXIMUM ALLOWABLE BOW: .005 [0.13]IN/IN.
3. MAXIMUM PIN VARIATIONS BETWEEN ANY
TWO PINS: .010 [0.25].
FILL T-1M6-XX-XX-2
4. MINIMUM TERMINAL PUSHOUT FORCE: 2 LBS.
FILL HTMS-50-X
5. MAXIMUM PIN ROTATION IN BODY: 2°.
6. MAXIMUM CUT FLASH .010 [0.25].
7. TUBE POSITIONS -07 THRU -50. POSITIONS -01
THRU -06 ARE TO BE LAYER PACKAGED.
8. FOR -D, USE DWM-50-D WHEN RAN ON BOARD
STACKER AUTOMATION, HTMS-50-D FOR ALL
OTHER PROCESSES. FOR -S, USE HTMS-50-S.
9. FOR -L, -S & -G PLATING, GOLD WILL BE ON CONTACT AREA.
CRITICAL DIMENSION INSPECTION INSTRUCTION
TABLE
IN-PROCESS INSPECTION
HDWM-XX-XX-XX-X-XXX-XXX
NO OF POS
(-01 THRU -50)
OPTION
POLARIZING SPECIFICATION
XXX INDICATES POS. TO BE OMITTED
(SEE FIG 1 AND 2)
BOARD SPACE
-XXX: BOARD SPACE
MAX = "L" - .120[3.05]
BODY SPECIFICATION
-S: SINGLE (USE HTMS-50-S)
-D: DOUBLE (USE HTMS-50-D)
C1, C3
C2
02
LEAD STYLE
SEE TABLE 1
PLATING SPECIFICATION
-G: 10µ" SELECTIVE GOLD IN CONTACT AREA,
3µ" SELECTIVE GOLD ON TAIL.
-T: MATTE TIN ON ENTIRE PIN.
-S: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL.
-TM: MATTE TIN ON ENTIRE PIN.
-SM: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL.
-L: 10µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL.
01 03
C
NO OF POS X .050[1.27]
.018 0.46 REF
C1-B-DC
[
+.002[0.05]
-.010[0.25]
]
CONTACT
AREA
2 MAX SWAY
(EITHER DIRECTION)
.100 2.54 REF
03 02 01
.096 2.44 REF
.196 4.98 REF
.000 0.00 MIN
(SEE NOTE 3)
(SEE NOTE 8)
-XXX±.008[0.20]
BOARD SPACE OPTION
(.200[5.08] MIN)
(MAX = "L" - .120[3.05])
C
C2-B-DC
"L"
REF
.100 2.54
REF (TYP)
C3-B,I-DC
C
.120±.008 3.05±0.20
.050 1.27
(TYP)
2 MAX SWAY
(EITHER DIRECTION)
HTMS-50-D
.020 0.51 REF
(DOUBLE BODY SPECIFICATION)
FIG 1
(SEE NOTE 5)
T-IM6-XX-XX-2
HTMS-50-S
(SINGLE BODY SPECIFICATION)
(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
FIG 2
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
.XX: .01 [.3]
2
.XXX: .005 [.13]
.XXXX: .0020 [.051]
ANGLES
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
DESCRIPTION:
DWG. NO.
MATERIAL:
DO NOT SCALE DRAWING
INSULATOR:
LCP, UL 94 VO, COLOR: BLACK
TERMINAL: PHOS BRONZE
SHEET SCALE: 12:1
HI TEMP BOARD SPACING MICRO STRIPS
HDWM-XX-XX-XX-X-XXX-XXX
F:\dwg\sw\exisprod\Assembly\050\HDWM-XX-XX-XX-X-XXX-XXX-ASM.SLDDRW
BY:
G REIDINGER 08/03/1992
SHEET
1
OF
1
Phase-locked loop
The phase-locked loop R1 gives 10K and C1 gives 0.1uf. I want to set Fo. The DC power supply is 5V. The 9-pin input to the voltage-controlled oscillator is 2.5V. As a result, there is only a 20HZ squa...
18186571573 Analog electronics
Ideal direction of intelligent wiring system
With the continuous expansion of the scale of informatization, large-scale enterprise networks, the Internet, data centers, etc. have put forward higher requirements for cabling systems. The current i...
xyh_521 Industrial Control Electronics
About cc2530 emulator
Is there a circuit diagram of the CC2530 emulator? How can I make a downloader that can write programs for CC2530? ??? ??? Please help me....
78459258 RF/Wirelessly
About setting baud rate!!
As for the baud rate, I looked it up online and in books. . . I understand the concept. But why do we need to set the baud rate? ? Under what circumstances do we need to set the baud rate? ? These que...
1372794486 Analogue and Mixed Signal
Keil prompts that the target is not created
After the original program compiled successfully, I defined a variable in a header file, but then the program failed to compile, and the following things were promptedI checked the relevant reference ...
dj狂人 51mcu
The five years after graduation determine your fate - it is worth reading for those who are unwilling to be mediocre
As the "working emperor" Tang Jun said: "I think there are two types of people who should not compete with others for benefits and value returns. The first type of people are those who have just enter...
Cheer_up Talking about work

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1768  266  542  1133  671  36  6  11  23  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号