EEWORLDEEWORLDEEWORLD

Part Number

Search

DF11-ABTBH150C0.0013.019

Description
Mains Power Connector, 10/15A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size913KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

DF11-ABTBH150C0.0013.019 Overview

Mains Power Connector, 10/15A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

DF11-ABTBH150C0.0013.019 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedTIN OVER NICKEL
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3
MIL complianceNO
Power Connector Ratings10/15A, 250VAC
Manufacturer's serial numberDF11
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 with recessed Circuit Breaker TA45
DF
C14
70° C
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
side
- 2 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-pole
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
- All single elements are already wired
- Switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage- or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
Approvals
- VDE Certificate Number: 40011305
- UL File Number: E96454
- Unwired versions
- Line switch 1-pole
- Other rocker marking
- Variant with notch for V-Lock mating Cordsets
Alternative: version with line filter DF12
Substitute for type 6145
pdf, General Product Information, Approvals, RoHS, CHINA-RoHS,
Mating Connectors, e-Store, SCHURTER-Stock-Check, Distributor-
Stock-Check, Accessories
References
Weblinks
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10 A / 250 VAC; 50 Hz
1 - 15 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-10 °C to 55 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1/1.5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance Inlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical details
Circuit Breakers
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Line Switch
Material: Housing
Connectors

Reverse
[i=s]This post was last edited by nanasong on 2022-8-4 16:18[/i]Could you please tell me what is the use of the series resistor between the input and output of the inverter? The input signal is a 100M...
nanasong Analog electronics
How to stabilize the voltage when using a battery as a power source?
When using batteries as power sources, there will be troubles such as voltage drop and increased internal resistance. Therefore, I have always wanted to figure out: Can voltage stabilization be achiev...
liweiliang Power technology
Design of Duty Cycle Measurement Circuit Based on Differential Voltage Amplifier
Design of Duty Cycle Measurement Circuit Based on Differential Voltage AmplifierAuthor: Qi Dong, Wang Ninghui, Sun Bingquan1 Introduction   Duty cycle is one of the important parameters of pulse power...
fighting Analog electronics
How to capture the mobile phone screen using AT command?
How can I use AT commands to capture the contents of the phone screen (full screen or part of it)? Thank you....
shen001 Embedded System
Free 3 8962 chips, see picture
Free 3 8962 chips, BGA package, just pay the courier fee, the red line is...
fengzhang2002 Buy&Sell
Shortening integration time can improve the accuracy of dead reckoning navigation systems
[b][size=4]Reducing integration time can improve the accuracy of dead-reckoning navigation systems[/size][/b] [align=left][size=14pt]Automotive dead-reckoning[/i] (DR) navigation systems use a gyrosco...
dontium ADI Reference Circuit

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2394  2152  2308  752  1870  49  44  47  16  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号