PHE427HR7180JR06L2 Overview

Double metallized film pulse capacitor

PHE427
• Double metallized film pulse capacitor, polypropylene dielectric
• According to IEC 60384-17 Grade 1.1
L
B
TYPICAL APPLICATIONS
High frequency applications with high
current stress, such as deflection circuits in
TV-sets, protection circuits in SMPS and in
electronic ballasts.
CONSTRUCTION
Polypropylene dielectric with double
metallized polyester film as electrodes.
Encapsulation in self-extinguishing material
meeting the requirements of UL 94V-0.
H
0.5
p
d
b
l
TECHNICAL DATA
Rated voltage U
R
, VDC
Rated voltage U
R
, VAC
Capacitance range, µF
160
100
0.047–
6.8
250
160
0.00068–
4.7
400
220
0.00068–
2.2
630
300
0.00068–
1.2
1000
375
0.00068–
0.0082
p
7.5
10.0
15.0
22.5
27.5
37.5
±
±
±
±
±
±
0.4
0.4
0.4
0.4
0.4
0.5
d
0.6
0.6
0.8
0.8
0.8
1.0
std I max I
5
-1
5
-1
6
-1
6
-1
6
-1
6
-1
30
30
30
30
30
30
b
± 0.4
± 0.4
± 0.4
± 0.4
± 0.4
± 0.7
Capacitance values
Capacitance tolerance
Category
temperature range
Rated temperature
Voltage derating
Climatic category
In accordance with IEC E12 series.
±5% standard. Other tolerances on request
–55° C to +105° C
+85° C
Insulation resistance
w
ne
or
f
ot
N
The rated voltage is decreased with 1.3% / ° C
between +85° C and +105° C
55/105/56
gn
si
de
Measured at 23° C, 100 VDC 60s for U
R
< 500 VDC
and at 500 VDC for U
R
500 VDC
Between terminals:
C
0.33 µF:
100 000 MΩ
C > 0.33 µF:
30 000 s
Between terminals and case:
100 000 MΩ
Maximum values at 23°C
C
0.1 µF 0.1 µF < C
1.0 µF
1 kHz
0.03 %
0.03 %
10 kHz
0.04 %
0.06 %
100 kHz 0.15 %
C > 1.0 µF
0.03 %
Dissipation factor tanδ
δ
Inductance
Approximately 6 nH/cm for the total length of capacitor
winding and the leads.
The capacitors can withstand an unlimited number of pulses
with a dU/dt according to the article table. For peak to peak
voltages lower than the rated voltage (U
PP
< U
R
), the specified
dU/dt can be multiplied by U
R
/U
PP
.
Pulse rise time
ENVIRONMENTAL TEST DATA
Vibration
According to IEC 60068-2-6 test Fc. 10–500 Hz for lead space
22.5 mm,10–55 Hz for lead space
27.5 mm. 6 h with
0.75 mm amplitude or 98 m/s
2
(depending on frequency)
with the capacitor mounted on PCB with the supporting
area in contact with the PCB.
According to IEC 60384-1.
According to IEC 60068-2-29 test Eb. 4000 bumps at 390 m/s
2
with the capacitor mounted on PCB with the supporting
area in contact with the PCB.
According to IEC 60068-2-3 test Ca, severity 56 days.
Climatic sequence
Bump
Humidity
219
LIN bus and its application in automotive hierarchical network 2
Depending on the transmission conditions, message frames can be divided into six types: absolute frames, trigger frames, discrete frames, diagnostic frames, user-defined frames, and reserved frames [2...
frozenviolet Automotive Electronics
Award-winning live broadcast | Azure Sphere helps to provide stable, secure and flexible IoT solutions
With the advent of 5G and the maturity of artificial intelligence technology, the Internet of Things will usher in rapid development, bringing new opportunities and challenges to the entire industry. ...
zqy1111 Industrial Control Electronics
Accelerated life and accelerated degradation test design and data analysis issues
Accelerated life and accelerated degradation tests are important means to solve the reliability problems of high-reliability and long-life products. At present, accelerated life and accelerated degrad...
lynnyong Integrated technical exchanges
Three Trends That Will Determine the Future of Wireless Test Systems
At 7am, you wake up to classic rock music playing on your clock radio. What the hell is that? The RDS-equipped radio screen scrolls with digital text, "Wanted Dead or Alive - John Bon Jovi". While you...
cscl Test/Measurement
Date with Spring---Spring is back, everything is reviving
Spring is back, and everything is reviving. Spring in the Northeast comes later than in the south of the Yangtze River. Just like the current season, flowers are in full bloom, and plants are reviving...
RF-刘海石 Talking
How to use the purge device
[font=微软雅黑][color=#333333]The purge flow meter is mainly a constant flow system device composed of a constant current and a flow meter. It can be divided into two forms: a single meter and a panel. Es...
窗外的麻雀 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1665  1023  2280  2790  497  34  21  46  57  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号