EEWORLDEEWORLDEEWORLD

Part Number

Search

62-12312-C5-0300

Description
Interconnection Device
CategoryThe connector    The connector   
File Size171KB,2 Pages
ManufacturerGould Fiber Optics
Download Datasheet Parametric View All

62-12312-C5-0300 Overview

Interconnection Device

62-12312-C5-0300 Parametric

Parameter NameAttribute value
MakerGould Fiber Optics
Reach Compliance Codeunknown
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
1121 Benfield Blvd., Millersville, MD 21108
Toll Free: 800-54-GOULD
VOICE: 410.987.5600 FAX: 410.987.1201
EMAIL: info@gouldfo.com WEB: www.gouldfo.com
Patch Cords
Gould cable assemblies feature quality parts and guaranteed performance specifications.
• Specifications are per mated pair at both 1310nm and 1550nm.
Connector Insertion/Return Loss Specifications for Singlemode Fiber
End Number
Connector
Insertion Loss Typical Return Loss
2=
ST
< 0.50dB
>50dB
3=
FC
< 0.35dB
>50dB
4=
SC
< 0.35dB
>50dB
5=
LC
< 0.35dB
>40dB
6=
FC/APC
< 0.35dB
>60dB
7=
SC/APC
< 0.35dB
>60dB
DATA SHEET- Patch Cords
ORDERING INFORMATION
Product Number
6___- ___ ___ ___ ___ ___ - ___ ___ - ___ ___ ___ ___ 1
Patchcord
Type
2= singlemode
4= multimode
Testing Requirements
0= Insertion Loss testing data only
1= Insertion Loss and Return Loss testing data
2= Insertion Loss and Endface Geometry data
3= Insertion Loss, Return Loss
and Endface Geometry data
Fiber Type
03=Corning SMF-28, 100 Kpsi proof test on fiber
06= Corning Flexcore (5/125)
11= 50/125 Graded Index (Corning)
12= 62.5/125 Graded Index (Corning)
22= 200/230/500, 0.37NA SI MM HCS (Lucent)
23= 200/230/500, 0.48NA SI MM HCS (Lucent)
25= 100/140/250 Step Index (Lucent)
27= Corning Flexcore (7/125)
32= Corning SMF-28, 200 Kpsi proof test on fiber
54= Corning Flexcore (7/125), 200 Kpsi proof test on
fiber
Connector
End A
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Length in meters xx.xx
i.e.., 3 meters=0300
Connector
End B
0= Pigtail
Assembly
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Buffer Type
10= No buffering (not recommended!)
11= 900 micron, white, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
12= 900 micron, orange, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
13= 900 micron, blue, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
15= 900 micron, green, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
19= 900 micron, yellow, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
21= 900 micron, white, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
22= 900 micron, orange, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
23= 900 micron, blue, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
24= 900 micron, red, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
25= 900 micron, green, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
26= 900 micron, black, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
27= 900 micron, brown, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
28= 900 micron, gray/slate, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
29= 900 micron, yellow, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
31= 2.9 mm x 0.4mm, Kevlar Reinforced Tubing, yellow
32= 2.9 mm x 0.4 mm, Kevlar Reinforced Tubing, orange
33= 2.9 mm x 0.9 mm, Kevlar Reinforced Tubing, orange
34= 2.9 mm x 0.45 mm, Kevlar Reinforced Tubing, black
01/09/03
How does a PC communicate with multiple microcontrollers?
I need to put 100 sets of digital tubes (6 per set) in each grid with a spacing of 40CM. The data displayed is the number of things in the grid. I saw someone else's work. Each set of digital tubes is...
mega128 Embedded System
I hope experts can answer this question on microcomputer principles!
1. Suppose a data area is defined as follows: Suppose a data area is defined as follows: ORG 0100H NEME DB 'TOM', 20 DB 'ROSE', 25 DB 'KATE', 22 For the following groups of instructions, if they are l...
woshis Embedded System
How to make the FIFO in MCBSP generate a receive interrupt?
[i=s] This post was last edited by dontium on 2015-1-23 13:25 [/i] I need to let MCBSP receive 6 words into FIFO, generate a receive interrupt and read the data from FIFO. How to generate this interru...
烟头小徐 Analogue and Mixed Signal
TI Classroom Classic Analog Electronics Course Album (Continuously Updated)
[font=微软雅黑][size=3]TI, known as the "king of analog electronics", not only has a rich analog circuit product line, but also launched many very practical analog electronics courses. These courses are t...
EEWORLD社区 TI Technology Forum
Application of RF through-type power meter
[p=35, null, left][color=rgb(46, 46, 46)][font=微软雅黑, 宋体][size=18.6667px]In traditional communication systems, AM, FM or PM modulation is usually used. The RF power measurement of these transmitters ca...
ld056k Analog electronics
How to cure LED patch adhesive
[hide]贴片胶主要用来将元器件固定在印制板上,一般用点胶或钢网印刷的方法来分配,以保持元件在印刷电路板(PCB)上的位置,确保在装配线上传送过程中元件不会遗失。贴上元器件后放入烘箱或再流焊机加热硬化。它与所谓的焊膏是不相同的,一经加热硬化后,再加热也不会溶化,也就是说,贴片胶的热硬化过程是不可逆的。 SMT贴片胶的使用效果会因热固化条件、被连接物、所使用的设备、操作环境的不同而有差异。使用时要...
探路者 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2822  658  2864  2720  1809  57  14  58  55  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号