EEWORLDEEWORLDEEWORLD

Part Number

Search

5145.ABTWFJ20C0.231

Description
Mains Power Connector, 2A, 125/250VAC, Male,
CategoryThe connector    The connector   
File Size524KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

5145.ABTWFJ20C0.231 Overview

Mains Power Connector, 2A, 125/250VAC, Male,

5145.ABTWFJ20C0.231 Parametric

Parameter NameAttribute value
MakerSCHURTER
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60950; UL 94V-0; CSA; VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN COPPER
Contact completed and terminatedTIN
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3
MIL complianceNO
Power Connector Ratings2A, 125/250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Total number of contacts3
Base Number Matches1
POWER ENTRY MODULES /
GERÄTESTECKER-KOMBIELEMENTE
Power entry module Type 5145
– Panel mount: screw-on version, front-side
– Appliance inlet, circuit breaker type TA 45 and line filter
5145
Standard or
Medical filter
50
75
100
Characteristics
• Circuit breaker with line switch, 2-pole, non-illuminated or
illuminated
• Combined with thermal overload protection
• Optional with undervoltage- or remote trip release
• All single elements wired
Unwired versions available on request
Technical data
Rated voltage
Rated currents I
n1
)
125/250 VAC; 50/60 Hz
1–10 A; @T
a
40 °C; SEV, VDE, Semko
1–15 A; @T
a
40 °C; UL, CSA
0,1–10 A; VDE, see table 1
0,1–15 A; UL/CSA, see table 1
< 0,5 mA (250 V/60 Hz)
< 5 µA (250 V/60 Hz)
1,7 kVDC between L-N
2,7 kVDC between L/N-PE
–10 °C to +55 °C
10/055/21 acc. to IEC/EN 60068-1
IP 40 acc. to IEC 60529
suitable for equipment with prot. cl. I,
acc. to IEC 61140
quick-connect 6,3 x 0,8 mm
max. 8 mm
Thermoplastic, black, UL94 V–0
Filter
TA 45
Leackage current, Standard
Medical
Test voltage (2 sec)
Allowable ambient air
temperatures T
a
Climatic category
Degree of protection (front-side)
Protection class
Terminals
Panel thickness s
Materials: Housing
Appliance-inlet
acc. to. IEC/EN 60320-1/C14,
Protection class I, pin-temperature 70 °C
(cold condition)
Circuit breaker
acc. to IEC/EN 60934, UL 1077,
type TA45
CSA 22.2 no. 235.
2-pole rocker switch, illuminated or
non-illuminated.
Optional with undervoltage- or remote
trip release
Short circuit capacity Icn:
at In < 3 A / 240 VAC: 10 x In
at In
3 A / 240 VAC: 300 A
Line filter, standard and medical acc. to. IEC 60939, EN 133 200,
UL 1283, CSA C 22.2 no. 8
Technical details see page 202
Application note
The rated current of the line filter must be equal or higher than the
rated current of the circuit-breaker.
1)
126
www.schurter.com
ADC Test Voltage vs. Temperature
This article records the ADC test voltage and temperature measurement functions1. Configure a single channel of the ADC rule group as a voltage test, and configure a single channel of the ADC injectio...
eew_xQfw2M GD32 MCU
The UART-delivered program suddenly cannot send characters to the PC
I used the UART program that came with the computer and the TKS serial port debugging tool to receive characters from and send characters to the PC. After using SecureCRT_CN, I can only receive charac...
无果花香 stm32/stm8
Donggua's original article on RF solution for TPMS for trucks (2)
Donggua's original article on RF solution for TPMS for trucks (2)...
maker RF/Wirelessly
Please guide me, the program is correct, but 1602 does not respond, what is going on?
/******************************************* Development environment: CCSv5.4 Development board: TIVA C Launchpad (TM4C123GH6PM) Program function: ADC analog-to-digital converter Program description: ...
shero亚南 Microcontroller MCU
Who has IAR Getting Started Quick User Guide 1.10 (Chinese version)? Please share
Please share in various ways:Cry::Cry::Cry::Cry::Cry:...
qq497181566 Microcontroller MCU
About RAM usage!
In Windows CE, is there any API function that can get the total RAM, current RAM usage and usage rate? The function to get FalshROM can use KernelIoControl to get all directly. There should be a corre...
547948002 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1535  1199  2032  2448  1361  31  25  41  50  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号