EEWORLDEEWORLDEEWORLD

Part Number

Search

240-790-044SK-35P2MTEPANA

Description
D Type Connector, 35 Contact(s), Female, Solder Terminal, Plug,
CategoryThe connector    The connector   
File Size285KB,6 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

240-790-044SK-35P2MTEPANA Overview

D Type Connector, 35 Contact(s), Female, Solder Terminal, Plug,

240-790-044SK-35P2MTEPANA Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARD: MIL-STD-2120
Body/casing typePLUG
Connector typeOTHER D TYPE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
empty shellNO
Filter functionYES
IEC complianceNO
MIL complianceYES
Mixed contactsYES
Installation typeBOARD
OptionsGENERAL PURPOSE
Shell surfaceNICKEL
Shell materialALUMINUM ALLOY
Housing sizeK
Termination typeSOLDER
Total number of contacts35
Base Number Matches1
Vertical PCB Mount with Straight PC Tails
How To Order Filter Series 79 Connectors
Sample Part Number
Series
Contact Type
Insert Arrangement
Shell Material/Finish
EMI Spring
Filter Type
Filter Class
Mating Hardware Options
PC Tail Length
240-790-044
S
- Socket Contacts
(See Table I)
Aluminum Shell
ME
- Electroless Nickel
MT
- Nickel-PTFE
E
- Chem Film
Z2
- Gold
UC
- Zinc Cobalt with Black Chromate
J
- Cadmium with Yellow Chromate
NF
- Cad/O.D. over Electroless Nickel
E
- With EMI Spring
N
- No EMI Spring
C
- C Filter
P
- Pi Filter
X, Y, Z, A, B, C, D, E, F, G, J
(See Table II)
P
- Jackposts
N
- No Mating Hardware (See Table III)
A
- .125" (3.18)
B
- .250" (6.35)
C
- .375" (9.53)
240-790-044
Series 79 Filtered Plug
G
Notes
Series 79
Micro-Crimp
PC Tail Contacts
© 2013 Glenair, Inc.
240-790-044
S
H-66 ME
E
P
D
P
A
EMI Spring
Socket Contact
Shell
1. Assembly to be identified with Glenair’s name, part number,
and date code, space permitting
2. Ground spring is not compatible with Zinc Cobalt or Cadmium
platings. Ground spring is only available with Nickel, Teflon
Nickel, Gold, or Chem Film plating on the shell.
3. EMI Filtered plug connector designed to meet requirements
of MIL-STD-2120 and Glenair Series 79 specifications. Unless
otherwise specified herein, refer to Glenair specification 799-
008 for additional performance characteristics.
4. All contacts to have identical filter value. Other filter
arrangements available, contact factory
5. See pages G-32 to G-37 for PCB hole patterns
6. Dielectric Withstanding Voltage: 500 VDC (Filter Class X, Y, Z
are 250 VDC)
7. Insulation Resistance: 5,000 megohms @ 200 VDC
8. Current Carrying Capacity
23 Gage - 5 Amps max. for all layouts
16 Gage - 7.5 Amps max. for combo layouts / 13 Amps max. for
all-power layouts
12 Gage - 13 Amps max. for combo layouts / 23 Amps max. for
all-power layouts
9. Other filter styles (C-L, L-C, Unbalanced Pi, Multi-Stage,
Multi-Value) are available. Please consult factory with your
requirements.
Materials/Finishes:
Insulators - High Grade Rigid Dielectric / N.A.
Contacts - Copper Alloy / 50 microinches Gold over Nickel
Mating Hardware - 300 Series Stainless Steel / Passivated
Dimensions in inches (millimeters) and are subject to change without notice.
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
G-20
E-Mail: sales@glenair.com
Electronic Design Competition Analog Electronics - Analog Integrated Circuit Design
You can take a look at this old but still very valuable reference:)...
brian-law Electronics Design Contest
Motor Synchronous Control System and Communication Based on DSP and CAN
[size=4]The traditional multi-motor control system is suitable for occasions with low requirements, relatively simple, and relatively concentrated motor distribution. However, for occasions with high ...
fish001 DSP and ARM Processors
[I "painted" the periphery of the C2000 LaunchPad] -----Electronic Load_Summary
I have actually started working on this electronic load a long time ago. However, I have been doing it here and there without taking it seriously. Even now, I have not finished it completely. I plan t...
dontium Microcontroller MCU
Design of three-phase UPS for power system
In the power system, in order to ensure that important equipment with high power supply reliability requirements can work normally, power plants and substations should be installed with UPS. With the ...
zbz0529 Power technology
BT8896A Specification (Zhongke Bluexun)
Keep sharing, and like it if you like it!...
Fred_1977 Download Centre
What is the amplification factor of this op amp?
I calculated 1.5, I don't know if it is correct, please help me...
shijizai Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 609  1698  2192  477  2679  13  35  45  10  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号