EEWORLDEEWORLDEEWORLD

Part Number

Search

805-004-02-ZN15-37PA

Description
Circular Connector, 37 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size485KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

805-004-02-ZN15-37PA Overview

Circular Connector, 37 Contact(s), Aluminum Alloy, Male, Crimp Terminal, Receptacle,

805-004-02-ZN15-37PA Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE PLATED
Shell materialALUMINUM ALLOY
Housing size15
Termination typeCRIMP
Total number of contacts37
Base Number Matches1
A
B
C
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 5- 0 0 4
Series
-02
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
B
Position B
P
Pin
C
Position C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
EMI/EMC - Principles and Countermeasures (Part 5)
[b]2. Electromagnetic Interference EMI and Electromagnetic Compatibility EMC[/b] Electromagnetic interference (EMI), referred to as EMI, is divided into two types: conducted interference and radiated ...
草原狼王 Power technology
I went to the beach on the weekend and saw something good.
It's a beautiful spring day, let's go to the beach. The weather in the north has been good recently, with bright sunshine and suitable temperature. Especially at noon, it's nice to bask in the sun, fe...
yaoyuanytu Talking
ASAHI/AMERICA vortex flowmeter, after being disassembled and reinstalled, displays abnormality
Nothing else was moved, except when I replaced the pipe, I took it apart as a whole, and then installed it again, it was not working properly. The flow meter indicates a 4-20ma output signal, the mete...
eeleader-mcu Industrial Control Electronics
Is there any shortcut to quickly add packages in the package manager in AD?
How can I quickly add packages in the package manager, or can I only do it one by one? I'm new here and I need help from an expert:time::time:...
源海 PCB Design
TI Davinci DM6446 Development Guide - UBL Porting
[align=left] The programming of UBL is relatively simple compared to UBOOT, KERNEL, ROOTFS, device driver, and DSP development. Let's start with the startup of DAVINCI to understand the position and r...
kooking DSP and ARM Processors
Download and get a gift|Keysight Technology Test Equipment Report
Recently, Keysight Technologies commissioned Dimensional Research to conduct a survey to explore the current challenges in manufacturing high-quality electronic hardware products. In addition, the sur...
EEWORLD社区 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2739  2359  61  66  994  56  48  2  20  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号