EEWORLDEEWORLDEEWORLD

Part Number

Search

RFH34006WG

Description
POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.017A (COIL), 24VDC (COIL), 400mW (COIL), 16A (CONTACT), THROUGH HOLE-STRAIGHT MOUNT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size189KB,3 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

RFH34006WG Overview

POWER/SIGNAL RELAY, SPST, MOMENTARY, 0.017A (COIL), 24VDC (COIL), 400mW (COIL), 16A (CONTACT), THROUGH HOLE-STRAIGHT MOUNT

RFH34006WG Parametric

Parameter NameAttribute value
Processing package descriptionROHS COMPLIANT
stateActive
Relay typePOWER/SIGNAL RELAY
width13.2 mm
high16 mm
length or diameter29 mm
Maximum DC coil current0.0170 A
coil_input_supply_typeDC
DC coil operating voltage16.8 V
coil_power__mw_400
DC coil release voltage2.4 V
Coil resistance1440 ohm
coil_voltage_nom24 V
Maximum DC coil voltage24 V
contact_ac_max_power_rating_r_load4000VA@400VAC
contact_ac_max_rating_r_load16A@400VAC
Maximum AC contact current16 A
Maximum DC contact current16 A
contact_output_supply_typeAC/DC
Maximum AC contact voltage400 V
dielectric_strength_between_coil_and_contacts4000 Vrms
dielectric_strength_between_open_contacts1000 Vrms
Electrical life15000 Cycle(s)
end_contact_materialSilver Nickel
input_switching_control_typeRandom
Manufacturer SeriesRF
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours11 ms
cking_methodTRAY
Dimensions29mm X 13.2mm X 16mm
eference_standardUL; VDE
Relay actionMOMENTARY
elay_form1 FORM A
Relay functionSPST
release time7 ms
Terminal typeSOLDER
weigh20 g
dditional_featureQUICK CONNECT TERMINALS ALSO AVAILABLE
General Purpose Relays
SCHRACK
Power Relay RF
I
I
I
I
I
I
I
I
1 pole 16 A, 1 NO or 1 NC contact
Switching capacity 4000 VA
Coil power 400 mW
Reinforced insulation (EN 61810, 60335, 60730)
Ambient temperature up to 105°C
Quick connect terminals for load side
WG version: Materials in accordance to IEC 60335-1
RoHS compliant (Directive 2002/95/EC)
Applications
Oven control, electric heating, power supplies, air conditioning,
microwares, hobs
F0273-AI
Approvals
V
REG.-Nr.
of
A652,
Z
on request
E214025
Technical data approved types
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Limiting making capacity, max 4 s, duty factor 10%
Contact material
Minimum contact load
Mechanical endurance
Rated frequency of operation with / without load
Contact ratings
Type
Load
RF33, RFH3
11 A, 250 VAC, 85°C, EN61810-1
RF33, RFH3
16 A, 250 VAC, 85°C, EN61810-1
RF33, RFH3
20 A, 250 VAC, 85°C, EN61810-1
RF33, RFH3
25 A, 250 VAC, 70°C, EN61810-1
RFH3
11 A, 250 VAC, 105°C, EN61810-1
RFH3
16 A, 250 VAC, 105°C, EN61810-1
RFH3
18, 5 A, 250 VAC, 105°C, EN61810-1
RFH3
10 A, 400 VAC, 105°C, EN61810-1
1NO or 1NC
single contact
micro disconnection
16 A
240/400 VAC
4000 VA
25 A
AgNi90/10
12VAC / 500mA
10x10
6
cycles
6 / 1200 min
-1
Cycles
2.5x10
5
1x10
5
2.5x10
4
1.5x10
4
2.5x10
5
5x10
4
2x10
4
1.5x10
5
Coil data
Rated coil voltage DC coil
Coil power DC coil
Operative range
Coil insulation system according UL1446
5...60 VDC
typ. 400 mW
2
Class F
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
005
5
3.5
0.5
62+10%
403
006
6
4.2
0.6
90+10%
400
009
9
6.3
0.9
203+10%
399
+
012
12
8.4
1.2
360+10%
400
+
024
24
16.8
2.4
1440+10%
400
048
48
33.6
4.8
5520+10%
417
060
60
42.0
6.0
8570+10%
420
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. GK1
Issued 2007/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
IAR replaces source file
Hello everyone. When I use IAR, in order to avoid the original file being changed, I copied the original C file to another directory, removed the original file in the project, and added the newly copi...
犯错者 Embedded System
Calculation of energy storage filter capacitor of reverse series switching power supply Principle and design of switching power supply (Part 7)
[b]1-3-3. Calculation of energy storage filter capacitor of inverting series switching power supply[/b] The calculation method of energy storage filter capacitor parameters of inverting series switchi...
noyisi112 Power technology
Design of power domain isolation for voltage monitoring analog-to-digital converters
[align=center][color=rgb(85, 85, 85)][font="][size=14px][b]Author: TI Engineer Shen Jun [/b][/size][/font][/color][/align][align=left][color=rgb(85, 85, 85)][font="][size=14px]Power domain isolation i...
alan000345 Analogue and Mixed Signal
Question: Is there any IC that provides SPI interface and can provide Slave mode?
Can I modify the content of SPI communication synchronously at any time through the program? Thanks for your help....
黄小明 Embedded System
So touching, how can it sound so good...
The Greatness of the Sky - Zhou Anxin [url]http://pan.baidu.com/s/1c0vtIVI[/url]...
aibing Talking
50 ideas for learning C and programming
The following is what you should pay attention to when learning C++. Absolutely classic!! 1. Learn C++ as a new language (it has nothing to do with C! Really.); 2. Read "Thinking In C++", don't read "...
topembedded Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2003  2714  1721  2257  1610  41  55  35  46  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号