55.13.8.060.5030

Description
Electromechanical Relay, 3PDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.13.8.060.5030 Overview

Electromechanical Relay, 3PDT-CO, MBB, AC/DC Output

55.13.8.060.5030 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)48 V
Coil resistance1200 Ω
Maximum coil voltage (AC)66 V
Nominal coil voltage60 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER NICKEL
End contact platingGold
Number of terminals11
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count11
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style3 FORM C
Relay function3PDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
Base Number Matches1
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Problems encountered by ucos on complex tasks
The SD card task I created was tested on the hardware in the bare metal state without any problems. I created 4 subtasks under the UCOS operating system, three of which were running light tasks to pro...
a2743919 Real-time operating system RTOS
Ten important technical issues in enterprise virtualization projects China IDC Circle
Ten important technical issues for enterprise virtualization projects China IDC Circle Using virtualization technology to extract software from hardware and create a flexible and dynamic environment i...
ashsworld Embedded System
Research on distance measurement technology based on JN5168, no idea where to start
The title of the paper is "Research on Distance Measurement Technology Based on JN5168". I couldn't find any relevant information on the Internet and I don't know where to start. Is there any kind-hea...
初入江湖 MCU
【CN0267】Complete 4 mA to 20 mA loop-powered field instrument with HART interface
Circuit Functionality and Benefits The circuit shown in Figure 1 is a complete smart industrial loop-powered field instrument that provides a 4 mA to 20 mA analog output and a Highway Addressable Remo...
EEWORLD社区 ADI Reference Circuit
Large supply of solar lawn lights
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:58[/i] Standard lawn lamp, the whole lamp is made of plastic material, the lamp height is 120mm, the pillar diameter is 29mm, and it is...
鱼缸的水 Energy Infrastructure?
Help!!! I have encountered a problem with the platform transplantation, please help!!!
After the base-top box program was ported from the LST platform to the ST platform, because the compiler of the ST platform does not support 64-bit integers, but the program needs to implement 64-bit ...
xi19871208 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2737  2370  1713  1299  1927  56  48  35  27  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号