EEWORLDEEWORLDEEWORLD

Part Number

Search

62-12524-72-0300

Description
Interconnection Device
CategoryThe connector    The connector   
File Size171KB,2 Pages
ManufacturerGould Fiber Optics
Download Datasheet Parametric View All

62-12524-72-0300 Overview

Interconnection Device

62-12524-72-0300 Parametric

Parameter NameAttribute value
MakerGould Fiber Optics
Reach Compliance Codeunknown
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
1121 Benfield Blvd., Millersville, MD 21108
Toll Free: 800-54-GOULD
VOICE: 410.987.5600 FAX: 410.987.1201
EMAIL: info@gouldfo.com WEB: www.gouldfo.com
Patch Cords
Gould cable assemblies feature quality parts and guaranteed performance specifications.
• Specifications are per mated pair at both 1310nm and 1550nm.
Connector Insertion/Return Loss Specifications for Singlemode Fiber
End Number
Connector
Insertion Loss Typical Return Loss
2=
ST
< 0.50dB
>50dB
3=
FC
< 0.35dB
>50dB
4=
SC
< 0.35dB
>50dB
5=
LC
< 0.35dB
>40dB
6=
FC/APC
< 0.35dB
>60dB
7=
SC/APC
< 0.35dB
>60dB
DATA SHEET- Patch Cords
ORDERING INFORMATION
Product Number
6___- ___ ___ ___ ___ ___ - ___ ___ - ___ ___ ___ ___ 1
Patchcord
Type
2= singlemode
4= multimode
Testing Requirements
0= Insertion Loss testing data only
1= Insertion Loss and Return Loss testing data
2= Insertion Loss and Endface Geometry data
3= Insertion Loss, Return Loss
and Endface Geometry data
Fiber Type
03=Corning SMF-28, 100 Kpsi proof test on fiber
06= Corning Flexcore (5/125)
11= 50/125 Graded Index (Corning)
12= 62.5/125 Graded Index (Corning)
22= 200/230/500, 0.37NA SI MM HCS (Lucent)
23= 200/230/500, 0.48NA SI MM HCS (Lucent)
25= 100/140/250 Step Index (Lucent)
27= Corning Flexcore (7/125)
32= Corning SMF-28, 200 Kpsi proof test on fiber
54= Corning Flexcore (7/125), 200 Kpsi proof test on
fiber
Connector
End A
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Length in meters xx.xx
i.e.., 3 meters=0300
Connector
End B
0= Pigtail
Assembly
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Buffer Type
10= No buffering (not recommended!)
11= 900 micron, white, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
12= 900 micron, orange, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
13= 900 micron, blue, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
15= 900 micron, green, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
19= 900 micron, yellow, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
21= 900 micron, white, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
22= 900 micron, orange, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
23= 900 micron, blue, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
24= 900 micron, red, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
25= 900 micron, green, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
26= 900 micron, black, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
27= 900 micron, brown, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
28= 900 micron, gray/slate, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
29= 900 micron, yellow, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
31= 2.9 mm x 0.4mm, Kevlar Reinforced Tubing, yellow
32= 2.9 mm x 0.4 mm, Kevlar Reinforced Tubing, orange
33= 2.9 mm x 0.9 mm, Kevlar Reinforced Tubing, orange
34= 2.9 mm x 0.45 mm, Kevlar Reinforced Tubing, black
01/09/03
PCI9054 has a rough problem
It is a mature architecture in the company. I don't know what happened to it. The board ID in eeprom is correct, which should indicate that there is no problem from PCI to 9054. But the connection fro...
流浪的猥琐 Integrated technical exchanges
Ask a question about ZigBee networking
I have now made two base station (coordinator) boards, two terminal boards, two base stations (respectively marked as base station 1 and base station 2) with the same program, and two terminals (respe...
小心有毒 RF/Wirelessly
Is there something wrong with the RM0008 document?
RM0008 Rev11 Page 843:Bit 16 for OUT endpoint 0, bit 18 for OUT endpoint 3Is itBit 16 for OUT endpoint 0Bit 17 for OUT endpoint 1Bit 18 for OUT endpoint 2 ???How to understand it???0008.jpg (32.17 KB)...
ttyugg stm32/stm8
Urgent question: Can EDA software be redeveloped?
Is it possible to carry out secondary development of EDA software and use the software to perform the following operations one by one: "Modify device parameters---〉perform simulation---〉record results...
wilgachen FPGA/CPLD
When is the driver for the USB device loaded?
When is the driver of the USB device loaded? Please tell me in detail, thank you! ! !...
wy123wy123 Embedded System
error: A1355U: A Label was found which was in no AREA (keil3.22 (for arm))
2410h.sct(5): error: A1355U: A Label was found which was in no AREA LR_ROM1 0x00000000 { ; load region is wrong in this line, but for some reason ER_ROM1 0x00000000 0x0100000 { ; load address = execut...
hua1232925 ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1050  1946  2463  2301  263  22  40  50  47  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号