EEWORLDEEWORLDEEWORLD

Part Number

Search

8510K9

Description
Toggle Switch, SPST, Latched, 20A, 28VDC, Screw Terminal, Lever Actuator, Panel Mount-threaded,
CategoryMechanical and electronic products    switch   
File Size124KB,3 Pages
ManufacturerSafran Group
Download Datasheet Parametric View All

8510K9 Overview

Toggle Switch, SPST, Latched, 20A, 28VDC, Screw Terminal, Lever Actuator, Panel Mount-threaded,

8510K9 Parametric

Parameter NameAttribute value
MakerSafran Group
Reach Compliance Codecompliant
Actuator typeLEVER
body width16.13 mm
body height29.9 mm
Body length or diameter32.26 mm
Contact (AC) maximum rated R load15A@115VAC
Maximum contact current (AC)15 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Electrical life20000 Cycle(s)
Installation featuresPANEL MOUNT-THREADED
Maximum operating temperature66 °C
Minimum operating temperature-46 °C
sealENVIRONMENTALLY SEALED; IP66/67
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeTOGGLE SWITCH
Termination typeSCREW
Base Number Matches1
INDUSTRIAL—ENVIRONMENTALLY SEALED SWITCHES
Series—8510, 8511, 8512
Environmentally Sealed Toggle Switches
FEATURES
SPECIFICATIONS
• Completely sealed against dust, mois- • Watertight seal per MIL-STD-108E
ture, and other contaminants
exceeds IP66/67
• 1, 2 and 4 pole circuitry
• Thermoset molding materials meet flame
• One hole mounting for easy installation
retardant requirements
• Multi-circuits offered
• Temperature Range: -50°F to +150°F
• 2 & 3 position with maintained and
(-46°C to +66°C)
momentary action
• Life: 20,000 operations at rated load
• Molded-in terminal inserts
• Bushing: 15/32" - 32 thread
• Molded-in terminal numbers
• See 8520-8528 for UL recognized and
CSA certified version on page 13.
CURRENT RATINGS
No. of Catalog
Type of
Poles Number Operation
28VDC
Lamp Resistive Inductive
Load
Load
Load
5
20
15
4
15
10
7
20
15
5
18
10
5
20
12
4
18
10
115VAC
60 or 400Hz
Lamp Resistive Inductive
Load
Load
Load
3
15
10
2
15
7
4
15
15
2
11
8
4
15
15
2
11
8
1
2
4
8510
8511
8512
Maintained
Momentary
Maintained
Momentary
Maintained
Momentary
SELECTION TABLE
FLUSH TERMINAL SCREWS
8510
CIRCUIT WITH LEVER IN...
Up
Position
Center
Position
Down
Position (Keyway)
Catalog
Number
ON
ON
ON
ON
ON
ON
ON
NONE
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
NONE
NONE
OFF
OFF
NONE
OFF
OFF
NONE
NONE
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
NONE
NONE
ON
ON
ON
OFF
ON
ON
NONE
NONE
ON
ON
ON
8510K1
K9
K4
K6
K8
8510K5
K2
K7
K10
K11
8510K3
K12
K13
Catalog
Number
8511K1
K9
K4
K6
K8
8511K5
K2
K7
K10
K11
8511K3
K12
K13
8511K14
K15
K16
8511
TWO POLE
8512
FOUR POLE
ONE POLE
Catalog
Number
8512K1
K9
K4
K6
K8
8512K5
K2
K7
K10
K11
8512K3
K12
K13
8512K15
K16
K17
*
*
*
*
*
*
*
*
*
*
*
*
Momentary contact.
See Page 73 for circuit diagrams.
*
First of all, thank you for your patient guidance. Regarding DS1302, a new problem has arisen.
The reading and display of the second register of 1302 has been realized. But a new problem has arisen. When the second is an odd number, the display is normal, but when the second is an even number, ...
流氓小哥 51mcu
Forum exchange board debugging experience + program + protues simulation (serial port)
Serial port query method: the most commonly used method for microcontroller communication, and also the most common method for communication with PC. Experience: Mainly familiar with the setting of se...
ming1005 MCU
About IEC61850
I work in the power industry. The power system is now developing digital substations, which require products to have the functions required by the IEC61850 protocol. I wonder if anyone can provide me ...
saqi99 Embedded System
High frequency induction welding system based on GD32
In the era of information technology and electronic products, the performance requirements for electric soldering irons have also increased. Traditional electric soldering irons use indirect heating, ...
zhangchi643 GD32 MCU
Internet of Vehicles C++ Interface Development Engineer-Shanghai
[table=98%] [tr][td][float=right] [/float] [table=98%] [tr][td][float=right] [/float] [align=left][b][color=black]Responsibilities:[/color][/b][/align][align=left][color=black]Maintain existing RAMSES...
AnnieXu Recruitment
I found that there is a problem with the M8 library file on the DVD distributed by ST Seminar
The M8 firmware library on the DVD will find errors when used with the IAR compiler. But the strange thing is that its version number is the same as the one I use (which compiles normally on IAR)!Plea...
ricky03221115 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 450  2365  1026  1212  2117  10  48  21  25  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号