EEWORLDEEWORLDEEWORLD

Part Number

Search

805-003-02ZN12-26PC

Description
26 CONTACT(S), ALUMINUM ALLOY, MALE, CIRCULAR CONNECTOR, CRIMP, RECEPTACLE
CategoryThe connector    The connector   
File Size220KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

805-003-02ZN12-26PC Overview

26 CONTACT(S), ALUMINUM ALLOY, MALE, CIRCULAR CONNECTOR, CRIMP, RECEPTACLE

805-003-02ZN12-26PC Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE PLATED
Shell materialALUMINUM ALLOY
Housing size12
Termination typeCRIMP
Total number of contacts26
Base Number Matches1
A
B
C
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 5- 0 0 4
Series
-02
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
B
Position B
P
Pin
C
Position C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Confused!!! About the two SPs of Cortex-M3
After reading >, I know that Cortex-M3 has two stacks. How to determine whether the stack used by STN32 is MSP or PSP? In the keil simulation, SP shows that it is the same stack whether in the interru...
mfsmfs stm32/stm8
MSP430 ADC analog-to-digital routines
The following uses the design of a street light controller as an example to illustrate how to use ADC12. Street lights will go out when the brightness is above a certain value, and light up when the b...
fish001 Microcontroller MCU
PCB numbering problem
I'm drawing a PCB schematic now. It was automatically numbered before. Now I want to remove these numbers. How can I do it?...
langzi291 PCB Design
CCS for MSP430 problem help!
It prompts that there is an unrecognized preprocessing directive. Almost every line of code reports an error. This is the first time for a novice to use CCS to program MSP430. I really don’t know what...
请给我C代码 Microcontroller MCU
【LPC54100】SPI0 driving TFT LCD
[i=s]This post was last edited by yinyue01 on 2015-5-13 22:12[/i] [align=left][font=宋体]Today we use the SPI port of LPC54102 to drive TFT LCD. The principle of SPI will not be introduced in detail. Th...
yinyue01 NXP MCU
High-speed railway wind and rain safety monitoring and alarm system based on single chip microcomputer
Modify constants, set alarm values, etc. Intel's 8279 has a powerful keyboard display interface, which can expand a 4×4 keyboard and an external 5-digit LED display, making it have a good human-machin...
jamieyang MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1679  1986  811  1459  1330  34  40  17  30  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号