Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8771 Multi-Conductor - Audio, Control and Instrumentation Cable
For more Information
please call
1-800-Belden1
General Description:
22 AWG stranded (7x30) tinned copper conductors, conductors cabled, polyethylene insulation, overall
Beldfoil® shield (100% coverage), 22 AWG stranded tinned copper drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
3
22
7x30
TC - Tinned Copper
3
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PE - Polyethylene
0.4064
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
22
7x30
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.8382
Overall Cable
Overall Cabling Lay Length & Direction:
Length (mm) Direction Twists (twist/m)
50.800
Left Hand 19.686
Overall Cabling Color Code Chart:
Number Color
1
2
3
Black
Red
Clear
5.055 mm
Overall Nominal Diameter:
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +60°C
60°C (UL AWM Style 2093)
32.740 Kg/Km
160.135 N
50.800 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
NEC Articles:
CEC/C(UL) Specification:
AWM Specification:
EU Directive 2011/65/EU (ROHS II):
CM
800
CM
UL Style 2093 (300 V 60°C)
Yes
Page 1 of 3
04-07-2016
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8771 Multi-Conductor - Audio, Control and Instrumentation Cable
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Yes
01/01/2004
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
CSA Flame Test:
UL1685 UL Loading
FT1
Suitability
Suitability - Indoor:
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
75.463
Nom. Capacitance Cond. to Other Conductor & Shield:
Capacitance (pF/m)
134.521
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
49.215
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
38.3877
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Description
Current
10C Temperature Rise 2.9 Amps per conductor @ 25°C ambient
Put Ups and Colors:
Item #
8771 060U1000
8771 060U500
8771 0601000
8771 06010000
8771 060250
8771 060500
Putup
1,000 FT
500 FT
1,000 FT
10,000 FT
250 FT
500 FT
Ship Weight
23.000 LB
12.000 LB
24.000 LB
240.000 LB
6.250 LB
12.000 LB
Color
CHROME
CHROME
CHROME
CHROME
CHROME
CHROME
C
CY
Notes
Item Desc
3 #22 PE FS PVC
3 #22 PE FS PVC
3 #22 PE FS PVC
3 #22 PE FS PVC
3 #22 PE FS PVC
3 #22 PE FS PVC
Notes:
C = CRATE REEL PUT-UP.
Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'.
Revision Number: 3
© 2016 Belden, Inc
All Rights Reserved.
Revision Date: 08-05-2013
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 2 of 3
04-07-2016