EEWORLDEEWORLDEEWORLD

Part Number

Search

5424.2251.203

Description
Mains Power Connector, 2A, 250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size403KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5424.2251.203 Overview

Mains Power Connector, 2A, 250VAC, Female and Male, Solder Terminal, ROHS COMPLIANT

5424.2251.203 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARD: IEC/EN 60320-1/C14,IEC/EN 60320-2-2,/F UL 498; UL 94V-0, CSA C22.2, VDE
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderFEMALE AND MALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings2A, 250VAC
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts6
Power Entry Modules with Line Filter
www.schurter.com/PG06
IEC Appliance Inlet C14 Modular Assembling Options
Felcom 54
Standard- or Medical-Filter
Snap-In Version
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
Description
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fu-
seholder for fuse-links 5␠x␠20␠mm 1␠ or 2␠pole, Line filter in standard
and medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
Characteristics
Approvals
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
- VDE Certificate Number: 101307
- UL File Number: E72928
Other versions on request
References
Weblinks
- Line switch with other rocker marking
Alternative: version without line filter
Felcom 64
Alternative: Standard version
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.
5/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC 60320,
F acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C,
10 A, Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard Version, IEC 60939, UL 1283,
CSA C22.2 no. 8
Technical Details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
Connectors
1
Summary notes on learning McBSP module of TMS320F28335
Summary notes on learning McBSP module of TMS320F28335 1. How many McBSP interfaces are there in total? How many pins are there in each McBSP interface? TMS320F28335 has two McBSP interfaces in total....
Jacktang Microcontroller MCU
This is my first time making a program to read and write IC cards. I have a few basic questions I would like to ask you.
This is my first time to write a program to read and write IC cards, and I have a few basic questions to ask. 1. When writing data to a block, a lot of verification must be done before writing, such a...
sleepdragon1986 Embedded System
Stubborn error NMAKE: U1073: don't know how to make...
Hello everyone, I am a beginner, using Samsung 2440, and encountered the following error BUILD: [01:0000000045:ERRORE] NMAKE : U1073: don't know how to make 'E:\WINCE500\platformew2440\lib\ARMV4I\debu...
popfancier Embedded System
I don't understand this hardware problem. Please help.
Has anyone made an amplifier and comparison circuit? I've been working on something that needs a comparison circuit, but I just can't figure it out. It's so annoying. It seems that the chip uses lm386...
Codemaster Embedded System
There is a strange problem with stm32 driving LCD in keil online debugging. I don’t know the reason. Anyone with debugging experience can help me take a look!
I modified the LCD driver function myself, and the project compilation and linking were fine. After downloading it to the stm32 board, the LCD screen was white, and the reset, power-off, and power-on ...
秦皇 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2149  1563  67  1516  110  44  32  2  31  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号