EEWORLDEEWORLDEEWORLD

Part Number

Search

LS5320-9ERD3TB1

Description
AC-DC Power Factor Correction Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE
CategoryPower/power management    The power supply circuit   
File Size599KB,27 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LS5320-9ERD3TB1 Overview

AC-DC Power Factor Correction Module, 2 Output, 100W, Hybrid, METAL, CASE S02, MODULE

LS5320-9ERD3TB1 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE S02
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresADDITIONAL 12V SEMI-REGULATED OUTPUT AVAILABLE
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage13.2 V
Minimum output voltage
Nominal output voltage12 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputYES
Cassette Style
100 Watt AC-DC Converters
S Series PFC
100 Watt AC-DC Converters with PFC
Input voltage range from 85...264 V AC
1 or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
S Series
111
4.4"
3U
60
2.4"
12 TE
168
6.6"
Summary
The S 4000/S 5000 series of AC-DC converters represents
a flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified range. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected to pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19" rack systems
according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the LS 1000 and
LS 2000 in order to comply with IEC/EN 61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 15
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 27
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 11
Edition 01/01.2001
1/27
Weighing Instrument Calibration Notes
[align=left][color=rgb(34, 34, 34)][font="][size=18px]When a new system is used for the first time or after replacing an instrument or sensor, it must be calibrated before use. [/size][/font][/color][...
西黎 Test/Measurement
I want a Raspberry Pi or a dongle board, please give me a cheap price
rt. Send me a private message...
zca123 Buy&Sell
Learn about TI's bq24161+TPS2419 dual battery power supply solution
With the continuous improvement of the processing power and the continuous enrichment of functions of portable terminal products, the power consumption of terminal products is also increasing, so stan...
qwqwqw2088 Analogue and Mixed Signal
[AN-358 Application Note] Noise and Operational Amplifier Circuits
Introduction: Even considering all known and unknown impedance loads of the op amp, the output of the operational amplifier always contains signals that cannot be predicted based on the input signal a...
EEWORLD社区 ADI Reference Circuit
FreeModbus is ported on STM32.
[table=98%,rgb(238, 238, 238)] [tr][td][b][color=#FF0000]FreeModbus[/color][/b][color=#ffff00] was ported to STM32...1.5, and modscan32 was used for debugging. It can respond to commands, but no data ...
莫妮卡 stm32/stm8
【MSP430 Sharing】Application of MSP430 in Shock Wave Test System
Abstract: This article introduces the application of MSP430 in the wireless shock wave test system. By managing the wireless module power supply through software programming, the interference of the e...
hangsky Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1070  1227  546  2056  27  22  25  11  42  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号