EEWORLDEEWORLDEEWORLD

Part Number

Search

LK1301-7RD1B2

Description
AC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size1MB,26 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LK1301-7RD1B2 Overview

AC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, METAL, CASE K02, MODULE

LK1301-7RD1B2 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerBel
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
Nominal input voltage310 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage12.07 V
Minimum output voltage11.93 V
Nominal output voltage12 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputNO
Cassette Style
AC-DC Converters
K Series
150 Watt AC-DC (DC-DC) Converters
for 400 Hz Mains
Input voltage range from 85...255 V AC
1 or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
• Input frequency range 47...440 Hz
• No PFC
Extremely wide input voltage range
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
K Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K series of AC-DC (DC-DC) converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include wide input frequency
range (no PFC), high efficiency, high reliability, low output
voltage noise and excellent dynamic response to load/line
changes.
The converter inputs are protected against surges and tran-
sients occuring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified range. Certain types
include an inrush current limitation preventing circuit break-
ers and fuses from being damaged at switch-on.
All outputs are open- and short-circuit proof and are pro-
tected against overvoltages by means of a built-in suppres-
sor diode. The outputs can be inhibited by a logic signal ap-
plied to the connector pin 18 (i). If the inhibit function is not
used pin 18 must be connected to pin 14 to enable the out-
puts.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) und UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds the
limit. The outputs are automatically re-enabled when the
temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19" rack systems
according to DIN 41494, or be chassis mounted.
Important:
For applications with requirements for com-
pliance with IEC/EN 61000-3-2 (harmonic distortion)
please use our LK 4000 and LK 5000 series.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 13
Immunity to Environmental Conditions ........................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Description of Options .................................................... 20
Accessories .................................................................... 26
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 5
Auxiliary Functions ......................................................... 10
Edition 5/5.2000
1/26
Thonny Automatically set the time
When using Thonny, my colleague found that the system time was automatically set when saving files. After analyzing the download program by Thonny, I found that Thonny sent the following command:try:f...
dcexpert MicroPython Open Source section
Does anyone have a circuit diagram of a 555 astable oscillator with a 50% duty cycle?
I want to use 555 to make an astable oscillator with a 50% duty cycle. I would like to know the circuit and ask for your advice. Thank you....
PSIR Power technology
compilation
[i=s] This post was last edited by paulhyde on 2014-9-15 09:23 [/i] I want to ask, should I write the minimum system of a single-chip microcomputer in assembly or C? . . . . I see that everyone writes...
liuyong1989 Electronics Design Contest
I would like to ask, are there pull-up resistors and pull-down resistors inside the U-type and I-type IO of LPC1788?
Do the U-type and I-type IOs of LPC1788 have pull-up and pull-down resistors inside? The MODE bit3 and bit4 of its IOCON register are reserved bits. So is there a pull-up and pull-down resistor inside...
lxiao2001 NXP MCU
77Ghz single-chip millimeter wave sensor enables automatic parking
[align=left][color=rgb(85, 85, 85)][font="][size=14px][b]By Kishore Ramaiah, Texas Instruments[/b][/size][/font][/color][/align][align=left][color=rgb(85, 85, 85)][font="][size=14px]Have you ever spen...
alan000345 TI Technology Forum
Problems with converting Evc programs to vc
I have a program that operates files under EVC. Now I want to view the contents of the files. I want to convert the program to VC and view the contents of the output files. How should I convert it and...
topskycn123 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 276  2800  2182  724  188  6  57  44  15  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号