EEWORLDEEWORLDEEWORLD

Part Number

Search

C6D31DS29A3

Description
Card Edge Connector, 62 Contact(s), 2 Row(s), Female, Straight, 0.156 inch Pitch, Solder Terminal, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size76KB,2 Pages
ManufacturerThomas & Betts Corporation
Websitehttp://www.tnb.com/
Download Datasheet Parametric View All

C6D31DS29A3 Overview

Card Edge Connector, 62 Contact(s), 2 Row(s), Female, Straight, 0.156 inch Pitch, Solder Terminal, Black Insulator, Receptacle

C6D31DS29A3 Parametric

Parameter NameAttribute value
MakerThomas & Betts Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCANTILEVER TERMINALS
Board mount optionsHOLE .125-.137
body width0.37 inch
subject depth0.61 inch
body length5.684 inch
Body/casing typeRECEPTACLE
Connector typeCARD EDGE CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedTIN LEAD (100)
Contact point genderFEMALE
Contact materialCOPPER ALLOY
contact modeRECTANGULAR
Contact resistance10 mΩ
Contact styleBELLOWED TYPE
DIN complianceNO
Dielectric withstand voltage1500VDC V
Filter functionNO
IEC complianceNO
maximum insertion force2.224 N
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee0
MIL complianceNO
Manufacturer's serial numberC6D
Plug contact pitch0.156 inch
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
PCB contact row spacing5.08 mm
Plating thickness30u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.16 inch
Terminal pitch3.96 mm
Termination typeSOLDER
Total number of contacts62
UL Flammability Code94V-0
Evacuation force-minimum value.556 N
Cardedge
Cantilever Beam–Dip Solder
.156" CENTER-TO-CENTER
.200" ROW-TO-ROW
DIP SOLDER TAILS
.300" CARD SLOT DEPTH
LR49571
E60980
P
HYSICAL
P
ROPERTIES
I
NSULATION
R
ESISTANCE
:
5000 megohms minimum.
I
NSERTION
/W
ITHDRAWAL
F
ORCE
(D
AUGHTER
C
ARD
):
8 oz./2oz. average contact pair using .0620 steel
blade.
I
NSULATOR
B
ODY
:
High temp. glass filled
thermoplastic, UL rating 94V-O.
C
OLOR
:
Black
C
ONTACTS
:
High strength copper alloy.
C
ONTACT
P
LATING
:
50 microinches nickel
underplate with 30 microinches gold in the mating
area, tin/lead on tails, 100 microinches minimum
.156
E
LECTRICAL
P
ROPERTIES
O
PERATION
V
OLTAGE
:
1500 VDC (sea level)
C
URRENT
R
ATING
:
3 Amperes
I
NITIAL
C
ONTACT
R
ESISTANCE
:
10 milliohms
E
NVIRONMENTAL
P
ROPERTIES
O
PERATING
T
EMPERATURE
:
-55˚C to +125˚C
T
EMPERATURE
C
YCLING
:
MIL-STD-202 method 107
V
IBRATION
:
MIL-STD-202 method 204
D
AUGHTER
C
ARD
See page 347 for layout
.200
.200
.156
Mounting Styles
Thomas & Betts Electronics/OEM Division Tel: 901-252-5000 Fax: 901-252-1312
Dimensions shown are for reference only. Dimensions are in inches.
356
Electronic competition exchange
[i=s]This post was last edited by paulhyde on 2014-9-15 03:02[/i] Could you please send me a copy, thanks, [url=mailto:1015133791@qq.com]1015133791@qq.com[/url]...
msayhello Electronics Design Contest
[AN-757 Application Note] ADN2812 acquisition time
Introduction: When the ADN2812 uses the default working mode (i.e. locking to the input data mode), it can automatically lock to the input data mode without programming and external reference clock as...
EEWORLD社区 ADI Reference Circuit
I have to say that the old technology I have been exposed to since 2008 was still blocked at that time.
1-3. Input and output matching circuit The purpose of the matching circuit is to choose a way of acceptance. For those transistors that want to provide greater gain, the way is to accept and output it...
btty038 RF/Wirelessly
【MicroPython】Micropython PM detection
[i=s]This post was last edited by lkl0305 on 2016-6-13 14:53[/i] Today I would like to share with you a small experiment on PM2.5 detection using Micropython, using the climbing laser pm2.5 sensor pms...
lkl0305 MicroPython Open Source section
Calibration of medical devices
Calibration of medical devices 1. Thermometer calibration - use black body furnace + constant temperature water bath to calibrate two points 2. Sphygmomanometer calibration - using BP pump sphygmomano...
QWE4562009 Test/Measurement
AT89C2051 and STC microcontroller, which one is cheaper in the market?
Friends who know please tell me....
clark 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 811  1095  376  1905  2475  17  23  8  39  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号