EEWORLDEEWORLDEEWORLD

Part Number

Search

KURL-06BWCNU

Description
Barrier Strip Terminal Block, 60A, 2 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size86KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

KURL-06BWCNU Overview

Barrier Strip Terminal Block, 60A, 2 Row(s), 1 Deck(s)

KURL-06BWCNU Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresTHERMOPLASTIC, 94V-0
Fastening methodSCREW
Manufacturer's serial numberKU
Installation typeDIN RAIL
Number of layers1
Rows2
Number of channels6
Rated current60 A
Rated voltage600 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge6 AWG
Series KU
Base Mount Double Row Terminal Blocks
Single & Double Row
Filtered Connectors
SPECIFICATIONS
Rating:
60A, 600V*
Center Spacing:
.625” (15.88 mm)
Number of Poles:
2-12
Wire Range:
#6-22 AWG CU
Screw Size:
#10-32 brass nickel plated
Torque Rating:
20 in-lb.
Distance Between Barriers:
.437” (11.09 mm)
Mounting:
Base mount. For 35mm DIN rail mountable,
add ND prefix
Material:
Molded base: Black, UL rated 94V0
thermoplastic
Terminal plating: Nickel over brass
Operating Temperature:
105°C max.
Agency Information:
UL/CSA; CE Certified
* 60A rating achieved with #6 copper wire crimped to ring terminal.
Euro-MAG Series
PCB – Spring Clamp
B
.62
(15.9)
KU
Poles
02
03
04
05
06
07
08
09
10
11
12
A
2.50
3.12
3.75
4.37
5.00
5.62
6.25
6.87
7.50
8.12
8.75
B
1.62
2.25
2.87
3.50
4.12
4.75
5.37
6.00
6.62
7.25
7.87
KUX only
A
2.00
2.62
3.25
3.87
4.50
5.12
5.75
6.37
7.00
7.62
8.25
2.00
(50.8)
#10 screw
clearance
.43
(11.1)
.50
(12.7)
1.25
(31.8)
1.50
(38.1)
Base & Rail Mount
Connectors
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Part Numbering System
Series
Poles
Screw Options
Covers
Marking Strip
Power Distribution Blocks
KU
KU
KUH
KUX
KUSC
-
-
-
-
00
W
- screws shipped bulk
- brass washer head,
nickel plated
P
- steel screw w/pressure plate
zinc plated
B
- brass washer head, no plating
BP
- brass philslot, nickel plated
WC
- Top cover &
2 end plates
MT
NU
- matte finish
- Numbered 1 to 12,
horizontal
NUV
- numbered 1 to 12,
vertical
PT
- marker strip for cover
standard block
02
to
12
block
short block
standard w/shortring strap
& 4 shorting screws
KURL
- standard w/removable link
KUXSC
- short block w/shorting strap
& 4 shorting screws
KUXRL
- short block w/removable link
Accessories
WIRE MANAGEMENT PRODUCTS
MTMU##
Molded Marking Tape
Matte Finish
NUM##
Molded Markiing Tape
JU12
Jumper
12 Circuits
NUE
End Piece for NUC
NUC##
Cover
131
I would be grateful if someone could give me a copy of the PCB rules
Can someone give me a copy of the PCB design rules? Thanks for the export method....
大发明家 PCB Design
Non-magnetic AC/DC Power Supplies
One of the most common challenges when creating industrial power supplies is converting AC voltage power to DC voltage power. Almost all applications require changing AC voltage to DC voltage, from ch...
fish001 Analogue and Mixed Signal
AD9361 RF Agile Transceiver
Software Defined Radio (SDR) combines RF to baseband transceiver PHY and digital processors to provide a reusable and future-proof radio platform. SDR has many advantages, including software configura...
嗡嗡 ADI Reference Circuit
S5PV210 Timer
There are 4 types of timing devices in S5PV210, with different functions and features. 1. PWM timer(1) This is the most commonly used timer. The timer we usually refer to is this one. The timer in a s...
灞波儿奔 Microcontroller MCU
【PCB Design】Fully Automated Schematic Verification
[i=s]This post was last edited by ohahaha on 2018-3-19 15:19[/i] [align=left]Craig Armenti[/align][align=left]PCB Marketing Engineer at Mentor Circuit Board System Division. He has over 25 years of ex...
ohahaha PCB Design
Detailed explanation and selection of pull-up resistors and pull-down resistors
[size=4]1. Definition[/size] [size=4] [/size] [size=4]1. Pull-up means embedding an uncertain signal at a high level through a resistor! "The resistor also acts as a current limiter"! The same applies...
Aguilera Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 825  461  927  2069  1290  17  10  19  42  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号