EEWORLDEEWORLDEEWORLD

Part Number

Search

F384005P2.5

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size208KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

F384005P2.5 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

F384005P2.5 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberF38
Installation typePANEL
Number of layers1
Rows1
Number of channels5
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
F38 Series Filtered Terminal Blocks
SPECIFICATIONS
Ratings:
30A, 240VAC, 300VDC.
Center Spacing:
0.437" or 7/16" (11.10mm)
Wire Size:
# 10-22 AWG CU
Screw Size:
# 8-32 (# 6-32 available, consult factory)
Torque Rating:
15 in-lb.
Operating Temperature:
–55°C to +105°C.
Housing Material:
94VO Thermoplastic.
Molded Material:
Black, UL rated 94V0 thermoplastic.
Terminal Material:
Brass, Tin-Plated
Capacitance:
1,000 pF to 5,000 pF in either C or Pi Schematic
Dielectric Withstanding Voltage:
1000 VAC; 1700VDC
D.C. Resistance:
0.01 ohms max.
Agency Information:
UL/CSA, CE Certified
# of
Poles
2
3
4
5
6
7
8
A
A
Front Mount Rear Mount
1.67
2.10
2.54
2.98
3.41
3.85
4.29
1.88
2.32
2.76
3.19
3.63
4.07
4.51
B
C
D
FEATURES
• Rugged integrated construction of filtering elements
around a solid brass pin provides excellent EMI/RFI
filtering
• Filter element provides high insertion loss for EMI/RFI
filtering of AC and DC power and control lines
• 2 to 8 terminals standard – up to 16 poles available
• Cost-effective EMI solution for industrial interconnec-
tion filtering
• Termination options are straight lead, male or female
quick connect
• Custom and special options available including:
– Different capacitance values on each position
– Wire assemblies added to pins
Insertion Loss for 2,500 pF Pi Schematic
Typical Insertion Loss (dB) in 50 Ohm Circuit
30MHz . . . . . . . . . . .42 dB
50 MHz . . . . . . . . . . .45 dB
100 MHz . . . . . . . . . .50 dB
300 MHz . . . . . . . . . .68 dB
1000 MHz . . . . . . . . .70 dB
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
1.31
1.75
2.19
2.63
3.06
3.50
3.94
0.93
1.37
1.81
2.25
2.68
3.12
3.56
0.44
0.88
1.31
1.75
2.19
2.62
3.06
* Note: For other capacitance insertion loss, consult factory.
* Note: In inches. Available up to 16 poles. Consult factory.
O - Front Panel Mount
I - Rear Panel Mount
Base & Rail Mount
Connectors
Power Distribution Blocks
Part Numbering System
Series
Terminal Style
Mounting
# of Poles
Screw Options
Inches (Millimeters)
Filter Options
Capacitance
F 3 8
0
- straight lead
0
- front panel mount
02
to
08*
1
- 0.187" quick
with mount ends
connect (male)
1
- rear panel mount
2
- 0.187" quick
with #4-40 threaded inserts
connect (male)
3
- 0.250" quick
connect (male)
4
- 0.250" quick
connect (female)
Blank
- #8-32, steel, zinc plated
philslot BHMS (stnadard)
04
- #8-32, brass, nickel plated
philslot BHMS
92
- #8-32, steel, zinc plated
slotted BHMS
94
- #8-32, brass, nickel plated
slotted BHMS
C
- C Filter
P
- Pi Filter
.
1.0
- 1,000 pF + 100%-0%
2.5
- 2,500 pF + 100%-0%
5.0
- 5,000 pF + 100%-0%
WIRE MANAGEMENT PRODUCTS
* Note: Standard is 02-08 poles. Available up to 16 poles. Consult factory for availability.
Special electrical/mechanical configurations are available upon request from factory.
25
NSN Hangzhou Recruitment RF Manager/RF Engineer
Hello everyone, I'm Austin, a talent consultant. We are now looking for RF talents for NSN Hangzhou. We can work on mobile phones, repeaters, and base stations. But I'm going to NSN Hangzhou to work o...
austinwang Recruitment
Please tell me how to use addr2lineppc
Today I saw a post in the forum saying that addr2lineppc.exe can be used to locate the line of code where the error occurred. Link: http://topic.eeworld.net/u/20090228/22/7c632e53-5899-4205-adf7-21ab1...
videofanser Embedded System
ad09 Import Wizard Problem
When I click the import wizard on my ad09, a dialog box pops up. Has anyone encountered this situation before? How to solve it? Urgent...
511474896 PCB Design
Animation demonstration of capacitor working principle, charging and discharging experiment, capacitor filtering principle
1. Capacitor charging and discharging experiment 2. Capacitor working principle 3. Capacitor charging and discharging experiment 34)][font="]3. Working principle of capacitor filter circuit[/font][/co...
tiankai001 Integrated technical exchanges
How can I get a 90KHz result when TIM1 is set to trigger the ADC at 60KHz?
See the 3rd floor attachment for the code...
licaiquan77 stm32/stm8
Help: I want to make an Exynos 4212 schematic library, but I can't find the pinout information
As the title says, I recently wanted to draw a terminal device based on Exynos 4212, so I downloaded the User Manual from the official website, but there was no Pin Assignment in it. So I searched eve...
shiyi_jiang Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 409  2358  671  1246  542  9  48  14  26  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号