Part Number

Search

F381102P1.0

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size208KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

F381102P1.0 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

F381102P1.0 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberF38
Installation typePANEL
Number of layers1
Rows1
Number of channels2
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
F38 Series Filtered Terminal Blocks
SPECIFICATIONS
Ratings:
30A, 240VAC, 300VDC.
Center Spacing:
0.437" or 7/16" (11.10mm)
Wire Size:
# 10-22 AWG CU
Screw Size:
# 8-32 (# 6-32 available, consult factory)
Torque Rating:
15 in-lb.
Operating Temperature:
–55°C to +105°C.
Housing Material:
94VO Thermoplastic.
Molded Material:
Black, UL rated 94V0 thermoplastic.
Terminal Material:
Brass, Tin-Plated
Capacitance:
1,000 pF to 5,000 pF in either C or Pi Schematic
Dielectric Withstanding Voltage:
1000 VAC; 1700VDC
D.C. Resistance:
0.01 ohms max.
Agency Information:
UL/CSA, CE Certified
# of
Poles
2
3
4
5
6
7
8
A
A
Front Mount Rear Mount
1.67
2.10
2.54
2.98
3.41
3.85
4.29
1.88
2.32
2.76
3.19
3.63
4.07
4.51
B
C
D
FEATURES
• Rugged integrated construction of filtering elements
around a solid brass pin provides excellent EMI/RFI
filtering
• Filter element provides high insertion loss for EMI/RFI
filtering of AC and DC power and control lines
• 2 to 8 terminals standard – up to 16 poles available
• Cost-effective EMI solution for industrial interconnec-
tion filtering
• Termination options are straight lead, male or female
quick connect
• Custom and special options available including:
– Different capacitance values on each position
– Wire assemblies added to pins
Insertion Loss for 2,500 pF Pi Schematic
Typical Insertion Loss (dB) in 50 Ohm Circuit
30MHz . . . . . . . . . . .42 dB
50 MHz . . . . . . . . . . .45 dB
100 MHz . . . . . . . . . .50 dB
300 MHz . . . . . . . . . .68 dB
1000 MHz . . . . . . . . .70 dB
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
1.31
1.75
2.19
2.63
3.06
3.50
3.94
0.93
1.37
1.81
2.25
2.68
3.12
3.56
0.44
0.88
1.31
1.75
2.19
2.62
3.06
* Note: For other capacitance insertion loss, consult factory.
* Note: In inches. Available up to 16 poles. Consult factory.
O - Front Panel Mount
I - Rear Panel Mount
Base & Rail Mount
Connectors
Power Distribution Blocks
Part Numbering System
Series
Terminal Style
Mounting
# of Poles
Screw Options
Inches (Millimeters)
Filter Options
Capacitance
F 3 8
0
- straight lead
0
- front panel mount
02
to
08*
1
- 0.187" quick
with mount ends
connect (male)
1
- rear panel mount
2
- 0.187" quick
with #4-40 threaded inserts
connect (male)
3
- 0.250" quick
connect (male)
4
- 0.250" quick
connect (female)
Blank
- #8-32, steel, zinc plated
philslot BHMS (stnadard)
04
- #8-32, brass, nickel plated
philslot BHMS
92
- #8-32, steel, zinc plated
slotted BHMS
94
- #8-32, brass, nickel plated
slotted BHMS
C
- C Filter
P
- Pi Filter
.
1.0
- 1,000 pF + 100%-0%
2.5
- 2,500 pF + 100%-0%
5.0
- 5,000 pF + 100%-0%
WIRE MANAGEMENT PRODUCTS
* Note: Standard is 02-08 poles. Available up to 16 poles. Consult factory for availability.
Special electrical/mechanical configurations are available upon request from factory.
25
Ask a weak question
When using MAX232 to make an RS232 interface, is it necessary to use the RX and TX pins of the 51 microcontroller? Can other pins be used?...
yanxinghua Embedded System
IC41C16256-25K Function Tester
Hello: Simple operation can determine whether the chip is good or bad! IC41C16256-25K functional tester is the latest dedicated chip tester launched by CECCLab. It has the characteristics of simple op...
cecc-2010 Power technology
About GPS data receiving and 51 control serial port sending problem!!
Hello everyone!! I haven't been to the forum for a long time, I miss you all, hehe! My song ordering system is dead. I really can't figure out how to use time-sharing multiplexing. Oh! But I still wan...
51学习者 51mcu
Design of control system for six-axis rotor disc-shaped aircraft
[align=left]The design of the control system for the six-axis rotor disc-shaped aircraft seems to be very cool, so I decided to share it.[/align]...
Sur Microcontroller MCU
Found a bug in Quantus 11.0
It seems that TCL scripts cannot be executed...
chenzhufly FPGA/CPLD
The difference between reference manual and DATASHEET
Today I checked the official website of STM8L151 and found the data sheet, but it didn't mention much about how to develop. After searching for a long time, I found that there was also a Reference Man...
jiyiche MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1871  2674  1194  1030  1204  38  54  25  21  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号