Low Profile International Series Power Transformer
Part
Number
T-61001
T-61002
T-61003
T-61004
T-61005
T-61006
T-61007
T-61008
T-61009
T-61010
T-61011
T-61012
T-61013
T-61014
T-61015
T-61016
T-61017
T-61018
T-61019
T-61020
T-61021
T-61022
T-61023
T-61024
T-61025
T-61026
T-61027
T-61028
T-61029
T-61030
T-61031
T-61032
T-61033
T-61034
T-61035
T-61036
T-61037
T-61038
T-61039
T-61040
T-61041
T-61042
VA
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
12.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
2.5
5.0
10.0
20.0
30.0
56.0
Secondary Ratings
--- Series --- --- Parallel ---
V
I(Amps) V I (Amps)
10.0
10.0
10.0
10.0
10.0
10.0
12.6
12.6
12.6
12.6
12.6
12.6
16.0
16.0
16.0
16.0
16.0
16.0
20.0
20.0
20.0
20.0
20.0
20.0
24.0
24.0
24.0
24.0
24.0
24.0
28.0
28.0
28.0
28.0
28.0
28.0
36.0
36.0
36.0
36.0
36.0
36.0
0.25
0.5
1.0
2.0
3.0
5.6
0.2
0.4
0.8
1.6
2.4
4.4
0.15
0.31
0.62
1.25
1.9
3.5
0.12
0.25
0.5
1.0
1.5
2.8
0.1
0.21
0.42
0.83
1.25
2.33
0.09
0.18
0.36
0.72
1.06
2.0
0.07
0.14
0.28
0.56
0.82
1.56
5.0
5.0
5.0
5.0
5.0
5.0
6.3
6.3
6.3
6.3
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
10.0
10.0
10.0
10.0
10.0
10.0
12.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
14.0
14.0
14.0
14.0
18.0
18.0
18.0
18.0
18.0
18.0
0.5
1.0
2.0
4.0
6.0
11.2
0.4
0.8
1.6
3.2
4.8
8.8
0.3
0.62
1.25
2.5
3.8
7.0
0.24
0.5
1.0
2.0
3.0
5.6
0.2
0.42
0.84
1.66
2.5
4.66
0.18
0.36
0.72
1.44
2.12
4.0
0.14
0.28
0.56
1.12
1.64
3.12
Dual Primaries: 115/230V, 50/60 Hz
3 Flange Bobbin Design
6 VA Ratings
FOR 2.5 T0 56.0 VA
L
W
--
Hi-Pot 4000 VRMS
Parallel External
Connections:
6-3, 1-4 & 10-7, 9-12
Series External
Connections:
4-3 & 9-10
H
PRIMARY
1
3
4
6
A
B
A
C
Schematic
F
6
4
3
7
9
10
12
E
1
FOR 2.5 T0 10.0 VA
A
B
A
FOR 2.5 TO 10.0 SERIES
6
4
3
1
7
9
10
11
12
.187 MIN
(4.75)
7
9
10
12
SECONDARY
FOR 20.0 T0 56.0 VA
D
FOR 20.0 TO 56.0 SERIES
A
A
A
7
9
10
11
12
SECONDARY
Materials used in construction of
this component meet or exceed
UL Class B and can be operated
up to 130
o
C
4 000 Volts RMS Hipot Test - Dual
Non-concentric Bobbins and insulating
Shroud Provide High Isolation and
Reduced Capacitance
NON-CONCENTRIC WINDING:
Primary and Secondary are wound
side-by-side rather than layered.
The added isolation reduces inter-
winding capacitance, eliminating
the need for an electro-static shield.
Additionally, it reduces radiated
magnetic fields.
Specifications are subject to change without notice
Size
(VA)
2.5
5.0
10.0
20.0
30.0
56.0
Dimension in Inches
L
W
H
A*
1.625
1.625
1.875
2.250
2.625
3.000
1.313
1.313
1.563
1.875
2.188
2.500
1.125
1.375
1.375
1.625
1.563
1.813
.200
.200
.200
.400
.550
.600
B
.250
.400
.400
.400
.275
.300
C
1.000
1.000
1.140
1.460
1.680
1.900
D
E
F
.40
.55
.60
1.063
1.063
1.250
1.500
1.75 2.19
2.00 2.50
INTL-PC 11/98
* For 20.0 TO 56.0 series secondary only, dimensions A is 1/2 of value shown
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane
Huntington Beach, California 92649-1595
Phone: (714) 898-0960 • FAX: (714) 896-0971