can be exceeded if the input current is less than 10mA.
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(V
CC
= 4.75V to 5.5V for MAX705/MAX707/MAX813L, V
CC
= 4.5V to 5.5V for MAX706/MAX708, T
A
= T
MIN
to T
MAX
, unless otherwise noted.)
PARAMETER
Operating Voltage Range
SYMBOL
V
CC
CONDITIONS
MAX70_C
MAX813LC
MAX70_E/M, MAX813LE/M
MAX705C, MAX706C, MAX813LC
MAX705E/M, MAX706E/M, MAX813LE/M
MAX707C, MAX708C
MAX707E/M, MAX708E/M
MAX705, MAX707, MAX813L
MAX706, MAX708
MIN
1.0
1.1
1.2
150
150
50
50
4.65
4.40
40
200
TYP
MAX
5.5
5.5
5.5
350
500
350
500
4.75
4.50
280
0.4
0.3
0.3
0.4
V
UNITS
V
Supply Current
I
SUPPLY
µA
Reset Threshold (Note 2)
Reset Threshold Hysteresis (Note 2)
Reset Pulse Width (Note 2)
V
RT
4.50
4.25
140
V
CC
- 1.5
V
mV
ms
t
RS
RESET
Output Voltage
RESET Output Voltage
Watchdog Timeout Period
WDI Pulse Width
Low
WDI Input Threshold
High
WDI Input Current
t
WD
t
WP
I
SOURCE
= 800µA
I
SINK
= 3.2mA
MAX70_C, V
CC
= 1V, I
SINK
= 50µA
MAX70_E/M, V
CC
= 1.2V, I
SINK
= 100µA
MAX707, MAX708, I
SOURCE
= 800µA
V
CC
- 1.5
MAX707, MAX708, I
SINK
= 1.2mA
MAX813LC, I
SOURCE
= 4µA, V
CC
= 1.1V
0.8
0.9
MAX813LE/M, I
SOURCE
= 4µA, V
CC
= 1.2V
I
SOURCE
= 800µA
V
CC
- 1.5
MAX813L
I
SINK
= 3.2mA
MAX705, MAX706, MAX813L
1.00
1.60
V
IL
= 0.4V, V
IH
= (V
CC
) (0.8)
50
MAX705, MAX706, MAX813L,
V
CC
= 5V
MAX705, MAX706, MAX813L, WDI = V
CC
MAX705, MAX706, MAX813L, WDI = 0V
MAX705, MAX706, MAX813L,
I
SOURCE
= 800µA
MAX705, MAX706, MAX813L,
I
SINK
= 1.2mA
3.5
-150
V
CC
- 1.5
50
-50
V
0.4
2.25
0.8
150
s
ns
V
µA
WDO
Output Voltage
V
0.4
Maxim Integrated
2
MAX705–MAX708/MAX813L
Low-Cost, µP Supervisory Circuits
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 4.75V to 5.5V for MAX705/MAX707/MAX813L, V
CC
= 4.5V to 5.5V for MAX706/MAX708, T
A
= T
MIN
to T
MAX
, unless otherwise noted.)
PARAMETER
MR
Pull-Up Current
MR
Pulse Width
Low
High
MR
to Reset Out Delay (Note 2)
MR
Input Threshold
PFI Input Threshold
PFI Input Current
PFO
Output Voltage
I
SOURCE
= 800µA
I
SINK
= 3.2mA
t
MR
SYMBOL
MR
= 0V
CONDITIONS
MIN
100
150
0.8
2.0
t
MD
V
CC
= 5V
1.20
-25.00
V
CC
- 1.5
0.4
1.25
+0.01
250
1.30
+25.00
TYP
250
MAX
600
UNITS
µA
ns
V
ns
V
nA
V
Note 2:
Applies to both
RESET
in the MAX705–MAX708 and RESET in the MAX707/MAX708/MAX813L.
Start with tsm570ls1224, learn and update your goals for the week every day, start with the simple, light up the lights at a certain frequency, and add small 10-second interruptions. Set a flag and co...
[i=s]This post was last edited by nemo1991 on 2015-7-1 09:57[/i] In the process of learning C2000 DSP, in order to get familiar with the various modules of DSP, some peripheral modules such as sensors...
[color=darkred] As the fourth generation of green, energy-saving, power-saving and long-life lighting fixtures, LED light sources have emerged, attracted widespread attention and developed rapidly. Th...
Assumption: The development of V1.0 version has played a great guiding role in the second version. The second version will make the following improvements: 1. Power supply design. This is a very big p...
I applied for a TMS320C5416 development board on the official website. During use, I burned the CPLD program I compiled myself. Now I want to restore it. How can I find the CPLD program (CPLD plays th...
introduction
my country has a vast territory and a large population. The scale of housing construction is huge, and the amount of residential construction is large and wide. It is still on t...[Details]
0 Introduction
With the development of my country's economy, the number of motor vehicles continues to increase. The growth of existing roads and other hardware facilities can no longer meet t...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
The Mobile Industry Processor Interface (MIPI) Alliance is an organization responsible for promoting the standardization of software and hardware in mobile devices. It has released the D-PHY specif...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
1 Introduction
Ultrasonic waves have strong directivity, slow energy consumption, and can propagate over long distances in a medium, so they are used for distance measurement. Ultrasonic detec...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
I. Introduction
Since RS232 has a short communication distance (only 15 meters according to EAT/TAI-232 standard), and can only perform point-to-point communication, it cannot directly f...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]
Digital array radar (DAR) uses digital beam forming (DBF) in both receiving and transmitting modes to achieve flexible distribution and reception of RF signal power in the airspace, obtain excellent t...[Details]
TC9012F is a universal CMOS large-scale integrated circuit for infrared remote control signal transmission, suitable for remote control of TV, VTR, laser player and other equipment. In the market, ...[Details]
At very low temperatures, certain metals and alloys lose their resistance to electric
current
and become
superconductors
. Two parameters that are often measured are the transition ...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]