EEWORLDEEWORLDEEWORLD

Part Number

Search

DDU66F-200MD1

Description
Active Delay Line, 1-Func, 5-Tap, True Output, SMD-14
Categorylogic    logic   
File Size62KB,4 Pages
ManufacturerData Delay Devices
Download Datasheet Parametric View All

DDU66F-200MD1 Overview

Active Delay Line, 1-Func, 5-Tap, True Output, SMD-14

DDU66F-200MD1 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerData Delay Devices
Parts packaging codeDFP
package instructionSMD-14
Contacts14
Reach Compliance Codecompliant
JESD-30 codeS-XDFP-F14
Logic integrated circuit typeACTIVE DELAY LINE
Number of functions1
Number of taps/steps5
Number of terminals14
Output polarityTRUE
Package body materialUNSPECIFIED
encapsulated codeDFP
Package shapeSQUARE
Package formFLATPACK
Peak Reflow Temperature (Celsius)NOT SPECIFIED
programmable delay lineNO
Certification statusNot Qualified
Maximum seat height5.715 mm
Maximum supply voltage (Vsup)5.25 V
Minimum supply voltage (Vsup)4.75 V
Nominal supply voltage (Vsup)5 V
surface mountYES
Terminal formFLAT
Terminal pitch1.27 mm
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Total delay nominal (td)200 ns
DDU66F
5-TAP, TTL-INTERFACED
FIXED DELAY LINE
(SERIES DDU66F)
FEATURES
IN
1
14
12
T2
T4
GND
4
10
6
7
8
T5
T3
VCC
T1
data
3
®
delay
devices,
inc.
PACKAGES
IN
N/C
N/C
T2
N/C
T4
GND
1
2
3
4
5
6
7
14
13
12
11
10
9
8
VCC
N/C
T1
N/C
T3
N/C
T5
Five equally spaced outputs
Fits standard 14-pin DIP socket
Low profile
Auto-insertable
Input & outputs fully TTL interfaced & buffered
10 T L fan-out capability
2
DDU66F-xx
DIP
DDU66F-xxA2 Gull-Wing
DDU66F-xxB2 J-Lead
DDU66F-xxME7 Military DIP
DDU66F-xxD1
DDU66F-xxD4
DDU66F-xxMD1
DDU66F-xxMD4
Com. SMD
Com. SMD
Mil. SMD
Mil. SMD
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The DDU66F-series device is a 5-tap digitally buffered delay line. The
IN
Signal Input
signal input (IN) is reproduced at the outputs (T1-T5), shifted in time by an
T1-T5 Tap Outputs
amount given by the device dash number. For dash numbers less than 25,
VCC
+5 Volts
the total delay of the line is measured from T1 to T5, with the nominal value
GND Ground
given by the dash number. The nominal tap-to-tap delay increment is
given by 1/4 of this number. The inherent delay from IN to T1 is nominally 3.5ns. For dash numbers
greater than or equal to 25, the total delay of the line is measured from IN to T5, with the nominal value
given by the dash number. The nominal tap-to-tap delay increment is given by 1/5 of this number.
SERIES SPECIFICATIONS
Minimum input pulse width:
40% of total delay
Output rise time:
2ns typical
Supply voltage:
5VDC
±
5%
Supply current:
I
CCL
= 32ma typical
I
CCH
= 7ma typical
Operating temperature:
0° to 70° C
Temp. coefficient of total delay:
100 PPM/°C
DASH NUMBER SPECIFICATIONS
Part
Number
DDU66F-4
DDU66F-6
DDU66F-8
DDU66F-10
DDU66F-12
DDU66F-16
DDU66F-20
DDU66F-25
DDU66F-30
DDU66F-35
DDU66F-40
DDU66F-45
DDU66F-50
DDU66F-60
DDU66F-75
DDU66F-100
DDU66F-125
DDU66F-150
DDU66F-175
DDU66F-200
DDU66F-250
Total
Delay (ns)
4
±
1.0 *
6
±
1.0 *
8
±
2.0 *
10
±
2.0 *
12
±
2.0 *
16
±
2.0 *
20
±
3.0 *
25
±
3.0
30
±
3.0
35
±
3.0
40
±
3.0
45
±
3.0
50
±
3.0
60
±
3.0
75
±
4.0
100
±
5.0
125
±
6.5
150
±
7.5
175
±
8.0
200
±
10.0
250
±
12.5
Delay Per
Tap (ns)
1.0
±
0.5
1.5
±
0.5
2.0
±
1.0
2.5
±
1.0
3.0
±
1.0
4.0
±
1.5
5.0
±
1.5
5.0
±
2.0
6.0
±
2.0
7.0
±
2.0
8.0
±
2.0
9.0
±
3.0
10.0
±
3.0
12.0
±
3.0
15.0
±
3.0
20.0
±
3.0
25.0
±
3.0
30.0
±
3.0
35.0
±
4.0
40.0
±
4.0
50.0
±
5.0
3.5ns
25%
25%
25%
25%
VCC IN
T1
T2
T3
T4
T5 GND
Functional diagram for dash numbers < 25
20%
20%
20%
20%
20%
VCC IN
T1
T2
T3
T4
T5 GND
Functional diagram for dash numbers >= 25
©
1997 Data Delay Devices
* Total delay is referenced to first tap output
Input to first tap = 3.5ns
±
1ns
NOTE: Any dash number between 4 and 250 not
shown is also available.
Doc #97020
2/5/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
Install the driver
Why does the installation of ccs_setup_win32 fail due to the lack of ASCII character?...
gwjhyy Integrated technical exchanges
How to implement process monitoring under WINCE?
What needs to be achieved now is: to be able to capture the opening event of a specified exe window, call your own program before opening, and determine whether to execute the intercepted exe event ba...
heyuqi Embedded System
Help: Looking for C6000 routines
I have just started learning C6000. I have some books on structure but no actual code. I hope some expert can share some C6000 routines, preferably c6713 or dm642, but others are also fine. Or tell me...
zhouluopei DSP and ARM Processors
Allegro adjusts the frame
How to enlarge a board frame once it has been drawn, because during layout, it is found that the board is too small to fit the components...
安圣基 PCB Design
What is an In-box driver? Thank you!
I recently read the driver section of the new version of WDK and saw a term called In-box driver. What type of driver does this refer to? Or what aspects of the driver does it refer to? Thank you!...
guoguzh Embedded System
Duty cycle of PWM wave?
Changing the duty cycle of the PWM wave can make the motor rotate, and changing the period of the PWM wave canadjust the speed. If the period is 500, what will be the difference if I change the duty c...
caviler Analogue and Mixed Signal

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1695  2386  1030  759  1370  35  49  21  16  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号