Active Single channel Analog signal
Isolation barrier (Vin & Iout)
T51/52/61/62_B
APPLICATIONS
Analog signal isolating barrier, is a signal
conditioner with electrical insulation between input
and output, which can receive the standard or
non-standard analog signal input from the scene,
and transmit a standard output signal to the
control room or DCS, to get three-port isolated
among power supply, input and output. It is
designed for translating signals of apparatus in
hazardous area, isolating and transforming these
signals into standard signals which can be
accepted by industry computer, DCS, PLC, or
user-specified special signals. It is widely used in
the industrial measurement systems, medical
electronic equipment, electrical equipment etc.
We
adopt
high
efficiency
magnetism
and
electricity isolated technology to achieve signal
isolation, with characteristics of high output
accuracy, good linearity and low temperature drift.
Isolation Power
Output Data
Input Data
Power Supply
Data
PRODUCT PROGRAM
Part
Number
T5230B
T5130B
T6135B
T6230B
T6233B
T6235B
Power Supply
24V
24V
24V
24V
24V
24V
Input
0-10V
0-10V
0-5V
0-5V
0-5V
0-5V
Output
0-20mA
4-20mA
4-20mA
0-20mA
0-20mA
0-20mA
Isolation
Channels
Power Output
NONE
NONE
12V
NONE
24V
12V
1
1
1
1
1
1
Note: We could also offer customer design for special input and output.
ELECTRICAL CHARACTERISTICS
Power Supply
Power Dissipation
Power Protection
Output Voltage
Output Current
Input Signal
Input Impedance
Overload
Output Data
Output Signal
Load
(Nominal Power Supply)±5%
≤2W
Reverse protection
(Nominal)±10%
≤25mA
See above
≥10MΩ
≤15V
See above
≤500Ω
(
At Output =20mA
)
FEATURES
●
Three port Isolation(input, output, power supply)
●
High accuracy (0.1% F.S.)
●
High linearity (0.1% F.S.)
●
Isolation voltage(2500VDC/60S)
●
High frequency response(15KHz)
●
Low temperature drift(35PPM/℃)
●
Industry class
(
Operation temp.:
-25℃
to +71℃)
●
High reliability(MTBF>500,000 hours)
TRANSMISSION CHARACTERISTICS
Offset
Gain Error
Temperature Drift
0.1%F.S.
0.1%F.S.
0.0035%F.S./℃ (-25℃ to +71℃)
ISOLATION CHARACTERISTICS
MODEL SELECTION
Galvanic Isolation
Isolation Voltage
Insulation
Resistance
Package style
Isolation power output
Power supply
Output
Input
Isolation amplifier
Three port Isolation(input, output, power supply)
2.5KVDC (Tested for 1minute and 1mA max, humidity < 70%)
100MΩ,
500VDC(Among signal input ,signal output, power supply
and isolation power output)
TXXXXB
OTHER CHARACTERISTICS
Ambient
temperature
Package
Safety Class
Operation temperature:-25℃ to +71℃
Transport and Storage temperature:-50℃ to +105℃
35mm DIN-rail package
IP20(IEC60529 / EN60529)
GB/T 18268(IEC61326-1)
About 60g
No dusts, gases of fiercely vibration, impulsion or gases that may
erode to the components surrounded
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou Industrial
District, Guangzhou, China
Tel: 86-20-38601850
Fax:86-20-38601272
Http://www.mornsun-power.com
EMC compliance
Weight
Application
environment
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output
load unless otherwise specified.
2. Only typical models listed, specifications of custom product may be different. Please contact our
service people directly for certain conditions.
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
T51/52/61/62_B
A/1-2008
Page 1 of 2
SINGLE CHANNEL SCHEMATIC DIAGRAM
2+
Power supply
1-
8+
Isolation
power output
7-
6+
Input
5-
4+
Output
3-
CONNECTION
1. Cross section area of wiring: 0.5mm -2.5 mm ;
2. Multi-strand wire, the length of bare wire is
about 8mm, fixed by the M4 bolt.
2
2
Application Note
1. Please read the user manual carefully before
using. If any questions please contact our
APPLICATION CIRCUIT DIAGRAM
5(-)
1(-)
technical support department.
2. Please do not use this product in hazardous
area.
Power supply
Input
6(+)
2(+)
3. The power supply of this product should be DC
power source. It is forbidden to use 220VAC
power supply.
4. To avoid equipment invalidation, or any failure,
users’ disassembling this product is forbidden.
7(-)
3(-)
Isolation
power output
8(+)
4(+)
Output
AFTER SERVICE
PACKAGING SIZE AND TERMINAL DESCRIPTION
1-
2+
3-
98
94.5
MORNSUN
1. Products
they
are
carefully
inspected
or
and
controlled before going out from our factory. If
operated abnormally
there were
Power supply-
Power supply+
Output-
Output+
Input-
Input+
Isolation power output-
anything wrong in the inner parts, please
contact with our agents near you or technical
support in our company as soon as possible.
2. 3 years warranty since the delivery date.
During the period of quality guarantee, our
company will repair or change free of charge if
product has any quality problem in the process
of normally using.
4+
5-
6+
7-
8+ Isolation power output+
25
41
Unit: mm
Tolerance:±0.5
INSTALLATION
DIN35mm standard rail installation
1. Upside of the instrument card in the
rail;
2. Push underside of the instrument into
the rail.
DISASSEMBLY
1. Use a screwdriver (Width of edge≤6mm),
cut in the metal card lock from the
underside;
2. Boost up the screwdriver and prize the
metal card lock downwards;
3. Pull the instrument out of the rail.
1
3
2
1
2
The copyright and authority for the interpretation of the products are reserved by Mornsun
Specifications subject to change without notice.
T51/52/61/62_B
A/1-2008