EEWORLDEEWORLDEEWORLD

Part Number

Search

ZF2UAORTB01AMB

Description
PUSHBUTTON SWITCH, DPDT, LATCHED, 0.5A, 30VDC, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size383KB,10 Pages
ManufacturerC&K
Environmental Compliance
Download Datasheet Parametric View All

ZF2UAORTB01AMB Overview

PUSHBUTTON SWITCH, DPDT, LATCHED, 0.5A, 30VDC, PANEL MOUNT, ROHS COMPLIANT

ZF2UAORTB01AMB Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator materialPOLYESTER
Actuator typePUSHBUTTON
body width9 mm
body height6.9 mm
Body length or diameter21 mm
center contact materialBRASS
Center contact platingSILVER
Contact (AC) maximum rated R load.5A@125VAC
Maximum contact current (AC)0.5 A
Maximum contact current (DC)0.5 A
Contact (DC) maximum rated R load.5A@30VDC
Contact resistance0.02 mΩ
contact timeMAKE-BEFORE-BREAK
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)30 V
End contact materialBRASS
End contact platingSILVER
Insulation resistance1000000000 Ω
JESD-609 codee4
Manufacturer's serial numberF
Installation featuresPANEL MOUNT
Maximum operating force4 N
Maximum operating temperature70 °C
Minimum operating temperature-40 °C
sealTOP AND BOTTOM SEALED
surface mountNO
Switch actionLATCHED
switch functionDPDT
Switch typePUSHBUTTON SWITCH
Terminal surfaceSilver (Ag)
Terminal materialBRASS
Termination typeSOLDER
F Series
Pushbutton Switches
A
Features/Benefits
Up to 10 poles per module
Various contact terminals
Various mounting & switch
ganging configurations
Pushbutton
Typical Applications
Audio selection
Digital equipment interface
Medical equipment interface
Mechanical indicator buttons
RoHS compliant
Specifications
SWITCHING POWER: F module max. AC/DC: Silver: 50 VA/15W,
Gold: 1 VA/300 mW.
SWITCHING VOLTAGE: F module max. AC/DC: Silver: 125/30V,
Gold: 50/30 V.
SWITCHING CURRENT: F module max. AC/DC: Silver: 0.5A/0.5A,
Gold: 0.04A/0.01A.
CARRYING CURRENT: Max at du = 20C: Silver: < 2A, Gold: <0.5A.
DIELECTRIC STRENGTH (50 Hz, 1 min.): Chassis/contact: ^1500V
Between contacts: ^1500V.
OPERATING LIFE “OA/EE” (24V/200mA): >105 operations
“GR”: >3.5 x 104 operations.
CONTACT RESISTANCE: Initial: Typical %10 mΩ, max. 20 mΩ
After operating life: %100 mΩ
INSULATION RESISTANCE: ^109
between open contacts,
^109
between chassis and contacts.
CAPACITANCE (at f = 10 kHz): %0.7 pF between 2 contacts.
TOTAL TRAVEL/LATCHING TRAVEL: 4.7mm/3.3mm (.185 inch/
.130 inch).
All models and options are RoHS compliant and compatible.
NOTE:
All models and options are RoHS compliant and compatible.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
TYPICAL F OPERATING FORCE: 2U: 6.5N (650 grams); 4U: 6.5N
(650 grams); 6U: 7.5N (750 grams); 8U: 9.0N (900 grams); 10U:
9.0N (900 grams).
EUROPEAN TYPICAL SF OPERATING FORCE:
2U: 3.5N±0.5N (350 grams±100 grams); 4U: 5N±1N (500
grams±100 grams); 6U: 6.5N±1N (650 grams±100 grams); 8U:
9.0N±1N (900 grams±100 grams).
OPERATING TEMPERATURE RANGE: -40˚C to 70˚C.
Materials
HOUSING: Polycarbonate UL 94V-0 or polyester UL 94V-0.
ACTUATOR: Polyester UL 94V-0.
MOVABLE CONTACTS: Bimetal brass, silver plated, gold plate
over nickel.
STATIONARY CONTACTS & TERMINALS: Brass, silver plated,
gold plated.
TERMINAL BOARD: Polyester UL 94V-0.
RETURN SPRING: Music wire.
TERMINAL SEAL: RTV adhesive sealant.
CHASSIS: Steel.
LOCKOUT PIN: Steel.
BLOCKERS: Steel.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages A-89 thru A-97. For additional options not shown in catalog, consult Customer Service Center.
If requesting only a switch, select either a North American or European switch as noted below. Chassis and buttons are sold
separately. If multiple stations are selected, we will assume all switches are the same unless noted otherwise.
North American Order Code - Switch Only
Designation
F
F Series
FLT
Light touch F series
ZF
Central mounted F series
Contact Arrangement
2U
2PDT
Mechanical Function
4U
4PDT
OA
Momentary
6U
6PDT
EE
Alternate (push-push)
8U
SPDT
GR
Interlock
10U
1OPDT
AOR
Central release
OASP
Momentary with lockout
GRSP
Interlock with lockout
Terminal Sealing
(NONE)
None
TB
Top/bottom
Terminal Style
(NONE)
Solder lugs & PC pins
01A
Cut solder lugs
01B
Cut PC pins, for other configurations,
consult factory
Electrical Function
(NONE)
BBM
M
MBB (special)
Contact Material
(NONE)
Silver, AG
AU
Gold
Dress nut*
*Central mounted F series only
(NONE)
No dress nut
B
Black
C
Chrome
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A-88
www.ck-components.com
The so-called DSP is floating-point co-processing, right?
Digital signal processing... I haven't done it before, I'm still learning [[i] This post was last edited by huo_hu on 2012-5-15 00:22 [/i]]...
huo_hu Microcontroller MCU
Which layout is better for the following two MP3s?
I hope everyone can give me some suggestions on which layout is better. I'm ready to make a board. I've got the VS1053 and will post it on the forum....
zhaojun_xf NXP MCU
Please help me, great God, see if there is anything that needs improvement in my graduation thesis. I really want to improve!
Design requirements of gas concentration detector based on at89s52: (1) Small size, light weight, easy to carry. The circuit uses a single-chip microcomputer as the main controller and is powered by a...
zyeight MCU
A casual talk on hybrid vigor
Recently, due to the death of the father of hybrid rice, a wave of learning and exploring hybrid rice has been set off on the Internet. On the one hand, it is to pay tribute to the father of hybrid ri...
se7ens Talking
(Please give an answer) Is it necessary to add OSIntExit() function when the interrupt function, especially Tmr_TickISR_Handler, exits?
Is it necessary to add OSIntExit() function when the interrupt function, especially Tmr_TickISR_Handler, exits?But I have seen that many interrupts written by others are not added at all, that is, no ...
lalahu Embedded System
Share the basics of linear regulators
[p=30, null, left][font=宋体][font=Verdana][color=#a0522d] Linear regulators have long been widely used in the industry. Before switch-mode power supplies became mainstream after the 1960s, linear regul...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1040  2242  1561  1483  2764  21  46  32  30  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号