Series DO, DMO
1-3.0 Amp • 60 Vdc • DC Output MINI-SIP
• Compact
for
High
Density PCB M
ount
• DC Control, DC Output
• Bipolar (DO)
or
M OSFET
(DM O) Output
• 3-10 Vdc Logic
Compatible Input
• Crydom's Patented Design
CURRENT DERATING CURVES
LOAD CURRENT (AMPS)
1.0
0.8
0.6
0.4
0.2
0
20
40
60
80
AMBIENT TEMPERATURE (¼C)
SPST-NO DC output relays in epoxy-
coated packages utilize the popular
.10" grid lead spacing. They are avail-
able with either bipolar transistor out-
put (DO), or the DMO063 with MOSFET
output rated at 3A/60 VDC.
Manufactured in Crydom's ISO 9002
Certified facility for optimum product
performance and reliability.
MODEL NO.
INPUT SPECIFICATIONS
➀
Control Voltage Range
Nominal Input Impedance
Typical Input Current @ 5 Vdc
Must Turn On Voltage
Must Turn Off Voltage
DO061A
➃
DO061B
➃
DM O063
➃
3.0-9.0 Vdc
270 Ohm
15 mAdc
3.0 Vdc
1.0 Vdc
3-60 Vdc
1.7-9.0 Vdc
270 Ohm
15 mAdc
1.7 Vdc
0.8 Vdc
3-60 Vdc
3.0-10.0 Vdc
200 Ohm
20 mAdc
3.0 Vdc
1.0 Vdc
0-60 Vdc
0-3.0 Adc
12.0 Adc(10 ms)
100 µAdc
0.4 Vdc
➁
OUTPUT SPECIFICATIONS
➀
Operating Voltage Range
Load Current Range
Max. Surge Current
DO Max. Load Current vs. Temp.
3
LOAD CURRENT (AMPS)
.02-1.0 Adc
5.0 Adc (1 Sec)
200 µAdc
1.5 Vdc
50 µsec
150 µsec
2
Max.Off-State Leakage @ Rated Voltage
Max. On-State Voltage Drop @ Rated Current
1
Max.Turn-On Time
Max. Turn-Off TIme
50 µsec
50 µsec
50 µsec
300 µsec
2500 Vrms
109 Ohm
8.0 pF
-30 to 80˚C
-30 to 125˚C
0
20
40
60
80
AMBIENT TEMPERATURE (¼C)
GENERAL SPECIFICATIONS
Dielectric Strength
DMO Max. Load Current vs. Temp.
➂
➂
Insulation Resistance (Min.) @ 500 Vdc
DO
.950
(24.1)
.400
(10.2)
MAX.
.200
(5.1)
4000 Vrms
109 Ohm
8.0 pF
-30 to 80˚C
-30 to 125˚C
0.15 oz. (4.3 g)
DMO
Max. Capacitance (Input/Output)
Ambient Operating Temperature Range
Ambient Storage Temperature Range
.500
(12.7)
LOAD
CONTROL
.250
(6.3)
M ECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
Thermally Conductive Epoxy
©2002 CRYDOM CORP, Specifications subject to change without
notice.
1
2
3
4
GENERAL NOTES
.015
(0.4)
.015
(0.4)
.030
(0.8)
.100
(2.5)
.500
(12.7)
.700
(17.8)
PIN
PIN
PIN
PIN
1:
2:
3:
4:
+DC LOAD
-DC LOAD
+DC CONTROL
-DC CONTROL
➀
➁
➂
➃
All parameters at 25˚C unless otherwise specified.
Typical On-State Resistance = .13
Dielectric and insulation resistance are measured between input and output.
Inductive loads should be diode suppressed.
FastFax Document No. 104
SERIES DO, DMO
Rev. 021202
PAGE 1 OF 1
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506